文献速递产科母胎医学

超声联合人工智能产前诊断左心发育不良综合征:性能与现有筛查方案的比较

Prenatal diagnosis of hypoplastic left heart syndrome on ultrasound using artificial intelligence: How does performance compare to a current screening programme?
PubMed 文献 · Prenat Diagn · 2023-09-30

该研究基于本地及国家数据估算现行胎儿筛查方案对左心发育不良综合征(HLHS)的敏感度为94.3%、特异度为99.985%,并利用四腔心超声视图训练ResNet人工智能模型。高敏感模型敏感度100%、特异度94.0%,高特异模型敏感度93.3%、特异度100%。作者认为独立使用人工智能模型性能略差于现行筛查方案,未来临床有效应用的关键在于人与人工智能的协作。

要点

  • 现行胎儿筛查方案对HLHS的估算敏感度为94.3%,特异度为99.985%。
  • 高敏感AI模型敏感度100%、特异度94.0%;高特异AI模型敏感度93.3%、特异度100%。
  • 高敏感模型预计产生45134例筛查阳性以额外检出14例HLHS,高特异模型则少检出2例并减少118例假阳性。

核心结论

  • 独立使用时,人工智能模型检测HLHS的性能略差于现行筛查方案,且前瞻性使用时性能可能进一步下降。
  • 作者认为人与人工智能的协作将是未来有效临床应用的关键。

研究设计与样本

  • 从本地和国家来源计算现行筛查方案性能,并使用胎儿心脏四腔心超声视图训练ResNet分类器人工智能模型。

主要发现

  • 现行胎儿筛查方案检测HLHS的估算敏感度为94.3%,特异度为99.985%。
  • 高敏感AI模型检测HLHS的敏感度为100%,特异度为94.0%。
  • 高特异AI模型检测HLHS的敏感度为93.3%,特异度为100%。
  • 高敏感模型预计产生45134例筛查阳性结果,以额外检出14例HLHS。
  • 高特异模型预计少检出2例HLHS,并减少118例假阳性。

关键数值与推荐

  • 现行胎儿筛查方案检测HLHS的估算敏感度为94.3%,特异度为99.985%。
  • 高敏感AI模型敏感度100%、特异度94.0%;高特异AI模型敏感度93.3%、特异度100%。
  • 高敏感模型:45134例筛查阳性,额外检出14例HLHS;高特异模型:少检出2例HLHS,减少118例假阳性。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 作者指出若独立使用,人工智能模型性能略差于现行筛查方案,且前瞻性使用时性能可能进一步下降。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Artificial intelligence (AI) has the potential to improve prenatal detection of congenital heart disease. We analysed the performance of the current national screening programme in detecting hypoplastic left heart syndrome (HLHS) to compare with our own AI model. METHODS: Current screening programme performance was calculated from local and national sources. AI models were trained using four-chamber ultrasound views of the fetal heart, using a ResNet classifier. RESULTS: Estimated current fetal screening programme sensitivity and specificity for HLHS were 94.3% and 99.985%, respectively. Depending on calibration, AI models to detect HLHS were either highly sensitive (sensitivity 100%, specificity 94.0%) or highly specific (sensitivity 93.3%, specificity 100%). Our analysis suggests that our highly sensitive model would generate 45,134 screen positive results for a gain of 14 additional HLHS cases. Our highly specific model would be associated with two fewer detected HLHS cases, and 118 fewer false positives. CONCLUSION: If used independently, our AI model performance is slightly worse than the performance level of the current screening programme in detecting HLHS, and this performance is likely to deteriorate further when used prospectively. This demonstrates that collaboration between humans and AI will be key for effective future clinical use.

来源:Prenat Diagn,查看原文。版权归原作者所有。

引用

  1. Day TG, Budd S, Tan J, et al. Prenatal diagnosis of hypoplastic left heart syndrome on ultrasound using artificial intelligence: How does performance compare to a current screening programme? Prenat Diagn. 2023. PMID: 37776084. doi:10.1002/pd.6445

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。