文献速递妇科生殖医学

近红外与宫腔镜引导下机器人激光纤维切除子宫切口憩室:一种新高精度技术

Near-infrared and hysteroscopy-guided robotic excision of uterine isthmocele with laser fiber: a novel high-precision technique.
PubMed 文献 · Fertil Steril · 2023-08-09

视频文章描述一例36岁三次剖宫产史继发不孕患者,因大型剖宫产瘢痕缺损且残余肌层厚度1.4 mm,采用二氧化碳激光纤维在宫腔镜与近红外引导下机器人切除并修补。手术顺利完成无并发症,术后3个月MRI显示切除部位残余肌层厚度10 mm。作者认为该组合技术是技术改进,尚需进一步研究确定金标准术式。

要点

  • 近红外 vision 可清晰界定宫腔镜透光无法显示的憩室边界,激光纤维实现毫米级切除。
  • 术后3个月MRI示切除部位残余肌层厚度10 mm,术前为1.4 mm。
  • 作者认为该设置是有用的技术改进,尚需进一步研究确定金标准。

核心结论

  • 目前子宫切口憩室手术管理尚无金标准技术,本文首次描述宫腔镜、近红外视觉与激光纤维联合用于机器人切除憩室。
  • 作者认为该特定设置是有用的技术改进,近红外联合宫腔镜精准定位可更清晰界定憩室边界,柔性激光纤维可实现毫米级切除且无明显侧向热扩散。
  • 作者指出尚需进一步研究以确定剖宫产瘢痕缺损患者的金标准手术技术。

研究设计与样本

  • 视频文章,报告一例36岁多产妇,有3次剖宫产史,因继发不孕6个月就诊。
  • 宫腔输卵管造影超声识别大型剖宫产瘢痕缺损,残余肌层厚度1.4 mm。
  • 因残余肌层厚度<3 mm不宜宫腔镜切除且未来妊娠有剖宫产瘢痕妊娠或胎盘异常风险,患者选择切除修补并签署知情同意。

主要发现

  • 机器人下使用二氧化碳激光纤维(Lumenis FiberLase)作为唯一能量源,功率5瓦进行分离,近红外视觉(da Vinci Firefly)激活后以20瓦激光在红外/灰度模式下切除Firefly高亮区域。
  • 子宫注射5单位血管加压素;宫腔镜为30度5 mm宫腔镜(Karl Storz);关闭采用双层缝合:4针2-0 Vicryl褥式缝合后连续2-0 PDS Stratafix,腹膜层以2-0 PDS Stratafix连续关闭。
  • 术中放置14 French Malecot导管于宫腔,膀胱回填确认完整性,修复区域覆盖Interceed防粘连屏障。
  • 手术顺利完成无手术并发症,术后访视未见并发症。
  • 术后3个月MRI显示切除部位残余肌层厚度10 mm,初始残余肌层厚度为1.4 mm。

临床怎么用

  • 作者认为近红外视觉联合精准宫腔镜定位可更清晰界定憩室边界,柔性激光纤维可实现毫米级切除且无明显侧向热扩散。
  • 作者指出目前无金标准术式,尚需进一步研究确定剖宫产瘢痕缺损患者的金标准手术技术。

局限性

  • 原文为视频文章,仅报告单例患者。
  • 作者指出尚需进一步研究以确定剖宫产瘢痕缺损患者的金标准手术技术。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To describe a novel high-precision technique for robotic excision of uterine isthmocele, employing a carbon dioxide laser fiber, under hysteroscopic guidance, and near-infrared guidance. DESIGN: Video article. PATIENT(S): A 36-year-old multipara with 3 prior cesarean sections presented to our infertility clinic with secondary infertility. The patient had been trying to conceive for 6 months without success. The patient underwent a hystero-salpingo contrast sonography that identified a large cesarean scar defect with a 1.4-mm residual myometrial thickness (RMT). The patient was counseled on surgical management with robotic approach because of RMT <3 mm precluding her from hysteroscopic resection and the potential risk for a cesarean scar ectopic or abnormal placentation if she were to become pregnant in the future. She elected to undergo excision and repair and informed consent was obtained from the patient. INTERVENTION(S): The robot was docked for traditional gynecologic robotic surgery. The uterus was injected with 5 units of vasopressin. We used a carbon dioxide laser fiber (Lumenis FIberLase) at a power of 5 watts as the sole energy source for dissection. The bladder was dissected off the uterus to identify the general area of the isthmocele. At that point, diagnostic hysteroscopy was performed using a 30-degree 5-mm hysteroscope (Karl Storz) to identify and enter the isthmocele. Near-infrared vision (da Vinci Firefly, Intuitive USA) was activated to precisely outline the extent of the isthmocele, which was not visible with simple transillumination from the hysteroscope. We proceeded with laser excision in infrared/gray scale using the laser at a power of 20 watts removing the entire area that was highlighted by the Firefly. After full excision of the isthmocele, the hysteroscope was removed and was eventually replaced by a uterine manipulator (ConMed VCare DX). The hysterotomy was closed with a 2-layer closure: 4 mattress sutures of 2-0 Vicryl (Ethicon) followed by a running 2-0 PDS Stratafix (Ethicon). The peritoneal layer was closed over these 2 layers with 2-0 PDS Stratafix (Ethicon) in a running fashion. The uterine manipulator was removed and a 14 French Malecot catheter (Bard) was placed in the uterine cavity to allow the healing to proceed with minimal risk of cervical stenosis. The bladder was backfilled to ensure integrity of the bladder wall. Interceed adhesion barrier (Gynecare) was then placed over the area of the repair and the procedure was concluded. The patient included in this video gave consent for publication of the video and posting of the video online including social media, the journal website, scientific literature websites (such as PubMed, ScienceDirect, Scopus, etc.), and other applicable sites. MAIN OUTCOME MEASURE(S): Completion of excision and repair of cesarean scar defect without surgical complications. RESULT(S): Robotic excision and repair of a sizable uterine isthmocele with carbon dioxide laser fiber and da Vinci Firefly was completed successfully without any surgical complications. Diagnostic hysteroscopy was used to positively identify the isthmocele and provide transillumination. However, the thickness of the cervical myometrium only allows the hysteroscopic light to shine through the thinnest portion of myometrium at the apex of the isthmocele, whereas the near-infrared vision allowed by the da Vinci Firefly technology was used to precisely identify the borders of the defect. The carbon dioxide laser was used to completely remove the defect while avoiding damage to delicate reproductive tissue and over-excision. No complications were identified during the postoperative visit. Magnetic resonance imaging 3 months after the surgery revealed an RMT of 10 mm at the location of excision compared with the initial RMT of 1.4 mm. CONCLUSION(S): Currently, there is no gold-standard technique for surgical management of isthmocele. This is the first description of the combined use of hysteroscopy, near-infrared vision, and laser fiber for the robotic excision of isthmocele. This specific setup proves to be a useful technical improvement. The use of near-infrared vision combined with precise hysteroscopic targeting allows much clearer definition of he isthmocele borders, and the flexible laser fiber allows millimetric xcision in the absence of appreciable lateral thermal spread. Further investigation is warranted to identify a gold-standard surgical technique for patients with cesarean scar defect.

来源:Fertil Steril,查看原文。版权归原作者所有。

引用

  1. Walker Z, Gargiulo A. Near-infrared and hysteroscopy-guided robotic excision of uterine isthmocele with laser fiber: a novel high-precision technique. Fertil Steril. 2023. PMID: 37567494. doi:10.1016/j.fertnstert.2023.08.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。