利用光声成像表征附件病变以改进超声O-RADS风险评估
这项前瞻性研究纳入68例(93个病变)拟行卵巢切除术的卵巢/附件病变患者,在术前进行超声及配准光声成像(PAI),计算相对总血红蛋白浓度(rHbT)和血氧饱和度(%sO2)。结果显示,联合CA125、O-RADS、rHbT和%sO2的模型预测恶性病变的AUC达0.970(95%CI 0.932-1),敏感度100%、特异度82%,优于单独或部分联合模型。
要点
- 恶性病变的rHbT显著高于良性病变,%sO2在恶性病变中较低但差异未达统计学显著。
- 联合CA125、O-RADS、rHbT和%sO2的模型AUC为0.970(95%CI 0.932-1),敏感度100%、特异度82%。
- rHbT、CA125、O-RADS和%sO2是恶性病变最重要的预测因子。
核心结论
- 将PAI衍生的rHbT和%sO2附加信息纳入后,可显著提高基于超声的O-RADS对附件病变的诊断性能。
研究设计与样本
- 前瞻性研究,纳入因疑似恶性卵巢/附件病变转诊行卵巢切除术的女性68例,共93个影像学病变。
- 参与者术前接受临床超声检查,随后进行配准超声和PAI检查。
- 由两名放射科医生使用超声O-RADS量表对每个卵巢/附件病变进行分级。
主要发现
- 手术病理显示14例患者为恶性卵巢/附件病变,2例仅为恶性输卵管,52例为良性发现。
- 恶性病变的rHbT显著高于良性病变;恶性病变的%sO2较低,但差异在所有良性类别中未达统计学显著。
- CA125单独模型AUC为0.789(95%CI 0.626-0.953),O-RADS单独模型AUC为0.857(95%CI 0.733-0.981)。
- CA125联合O-RADS模型AUC为0.883(95%CI 0.760-1),rHbT联合%sO2模型AUC为0.900(95%CI 0.815-0.985)。
- 联合全部四个预测因子(CA125、O-RADS、rHbT和%sO2)的模型AUC为0.970(95%CI 0.932-1),敏感度100%、特异度82%。
关键数值与推荐
- rHbT、CA125、O-RADS和%sO2是恶性病变最重要的预测因子。
- 联合全部四个预测因子的模型AUC为0.970(95%CI 0.932-1),敏感度100%、特异度82%。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To assess the impact of photoacoustic imaging (PAI) on the assessment of ovarian/adnexal lesion(s) of different risk categories using the sonographic ovarian-adnexal imaging-reporting-data system (O-RADS) in women undergoing planned oophorectomy. METHOD: This prospective study enrolled women with ovarian/adnexal lesion(s) suggestive of malignancy referred for oophorectomy. Participants underwent clinical ultrasound (US) examination followed by coregistered US and PAI prior to oophorectomy. Each ovarian/adnexal lesion was graded by two radiologists using the US O-RADS scale. PAI was used to compute relative total hemoglobin concentration (rHbT) and blood oxygenation saturation (%sO2 ) colormaps in the region of interest. Lesions were categorized by histopathology into malignant ovarian/adnexal lesion, malignant Fallopian tube only and several benign categories, in order to assess the impact of incorporating PAI in the assessment of risk of malignancy with O-RADS. Malignant and benign histologic groups were compared with respect to rHbT and %sO2 and logistic regression models were developed based on tumor marker CA125 alone, US-based O-RADS alone, PAI-based rHbT with %sO2 , and the combination of CA125, O-RADS, rHbT and %sO2. Areas under the receiver-operating-characteristics curve (AUC) were used to compare the diagnostic performance of the models. RESULTS: There were 93 lesions identified on imaging among 68 women (mean age, 52 (range, 21-79) years). Surgical pathology revealed 14 patients with malignant ovarian/adnexal lesion, two with malignant Fallopian tube only and 52 with benign findings. rHbT was significantly higher in malignant compared with benign lesions. %sO2 was lower in malignant lesions, but the difference was not statistically significant for all benign categories. Feature analysis revealed that rHbT, CA125, O-RADS and %sO2 were the most important predictors of malignancy. Logistic regression models revealed an AUC of 0.789 (95% CI, 0.626-0.953) for CA125 alone, AUC of 0.857 (95% CI, 0.733-0.981) for O-RADS only, AUC of 0.883 (95% CI, 0.760-1) for CA125 and O-RADS and an AUC of 0.900 (95% CI, 0.815-0.985) for rHbT and %sO2 in the prediction of malignancy. A model utilizing all four predictors (CA125, O-RADS, rHbT and %sO2 ) achieved superior performance, with an AUC of 0.970 (95% CI, 0.932-1), sensitivity of 100% and specificity of 82%. CONCLUSIONS: Incorporating the additional information provided by PAI-derived rHbT and %sO2 improves significantly the performance of US-based O-RADS in the diagnosis of adnexal lesions. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Zhu Q, Luo H, Middleton WD, et al. Characterization of adnexal lesions using photoacoustic imaging to improve sonographic O-RADS risk assessment. Ultrasound Obstet Gynecol. 2023. PMID: 37606287. doi:10.1002/uog.27452
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。