文献速递产科

STan辅助胎心监护与单纯胎心监护对急诊剖宫产率影响的比较:STan澳大利亚随机对照试验(START)

Comparison of effect of CTG + STan with CTG alone on emergency Cesarean section rate: STan Australian Randomized controlled Trial (START).
PubMed 文献 · Ultrasound Obstet Gynecol · 2023-01-01

在澳大利亚阿德莱德一家三级妇产医院开展随机对照试验,纳入≥36周单胎头位需持续电子胎心监护的产妇970例(967例纳入主要分析),比较CTG+STan与单纯CTG对急诊剖宫产率的影响。结果显示两组急诊剖宫产率无显著差异(22.2% vs 22.1%,校正相对风险1.02,95%CI 0.81-1.27,P=0.89),母儿不良结局率亦无差异。作者结论为STan辅助CTG未降低急诊剖宫产率,且样本量小于预期导致研究把握度不足,阴性结果可能为2型错误。

要点

  • STan辅助持续CTG未降低急诊剖宫产率(22.2% vs 22.1%,校正RR 1.02,95%CI 0.81-1.27,P=0.89)。
  • 两组母儿不良结局发生率无差异。
  • 实际入组970例少于计划样本量1818例,研究对≤5%绝对差异把握度不足。

核心结论

  • 在持续CTG基础上加用STan未降低急诊剖宫产率,且因样本量小于预期,该阴性结果可能为2型错误。

研究设计与样本

  • 随机对照试验,纳入≥36周单胎头位、分娩中需持续电子胎心监护的产妇,2018年1月至2021年7月在澳大利亚阿德莱德一家三级妇产医院开展,随机分为CTG+STan组或单纯CTG组,计划样本量1818例。

主要发现

  • 实际入组970例,967例纳入主要分析。
  • 急诊剖宫产在CTG+STan组为107/482(22.2%),在单纯CTG组为107/485(22.1%),校正相对风险1.02(95%CI 0.81-1.27),P=0.89。
  • 两组不良母体或新生儿结局发生率无差异。

局限性

  • 样本量小于预期,研究对≤5%的绝对差异把握度不足,阴性发现可能为2型错误。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate whether use of ST analysis of the fetal electrocardiogram (STan) as an adjunct to continuous cardiotocography (CTG) reduces the rate of emergency Cesarean section (EmCS) compared with CTG alone. METHODS: This was a randomized controlled trial of patients with a singleton fetus in cephalic presentation at ≥ 36 weeks' gestation, requiring continuous electronic fetal monitoring during labor at a tertiary maternity hospital in Adelaide, Australia, between January 2018 and July 2021. Participants were randomized to undergo CTG + STan or CTG alone. The calculated sample size was 1818 participants. The primary outcome was EmCS. Secondary outcomes included metabolic acidosis, a composite adverse perinatal outcome, and other maternal and neonatal morbidity and safety outcomes. RESULTS: The present study enrolled 970 women, of whom 967 were included in the primary analysis. EmCS occurred in 107/482 (22.2%) deliveries in the CTG + STan arm and in 107/485 (22.1%) in the CTG arm (adjusted relative risk, 1.02 (95% CI, 0.81-1.27); P = 0.89). There was no difference in the rate of adverse maternal or neonatal outcomes between arms. CONCLUSIONS: The addition of STan as an adjunct to continuous CTG did not reduce the EmCS rate. The smaller-than-anticipated sample size meant that this study was underpowered to detect absolute differences of ≤ 5% and, therefore, this negative finding could be due to a Type-2 error. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Kuah S, Simpson B, Salter A, et al. Comparison of effect of CTG + STan with CTG alone on emergency Cesarean section rate: STan Australian Randomized controlled Trial (START). Ultrasound Obstet Gynecol. 2023. PMID: 37289946. doi:10.1002/uog.26279

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。