子宫内膜癌机器人子宫切除术中的恶性腹膜细胞学污染
本研究纳入244例子宫内膜癌患者,在机器人子宫切除术及前哨淋巴结定位术前和术后分别获取腹膜细胞学,发现32例(13.1%)出现盆腔污染,污染与肌层浸润>50%、肿瘤>2cm、淋巴血管间隙浸润及淋巴结转移相关,与FIGO分期和组织学亚型无关。
要点
- 子宫内膜癌机器人子宫切除术后盆腔细胞学污染率为13.1%(32/244)。
- 污染与肌层浸润>50%、肿瘤>2cm、淋巴血管间隙浸润及淋巴结转移独立相关。
- 污染与FIGO分期或组织学亚型无关联。
核心结论
- 子宫内膜癌机器人手术过程中可发生恶性腹膜污染。
- 大病灶(>2cm)、深浸润(>50%)、淋巴血管间隙浸润和淋巴结转移均分别与腹膜污染独立相关。
- 腹膜污染是否增加疾病复发风险需在更大样本系列中研究,包括评估复发模式及辅助治疗的潜在影响。
- 在更好地理解子宫切除术中腹膜污染的临床影响之前,有必要采取措施减少腹膜污染。
研究设计与样本
- 研究在手术开始时从盆腔和膈下获取腹膜细胞学,在机器人子宫切除术及前哨淋巴结定位(SLNM)完成时仅从盆腔获取细胞学。
- 评估细胞学标本中恶性细胞的存在,比较术前和术后细胞学结果,盆腔污染定义为手术后细胞学从阴性转为阳性。
- 244例子宫内膜癌患者接受了机器人子宫切除术及SLNM。
主要发现
- 32例(13.1%)发现盆腔污染。
- 多变量分析中,盆腔污染与肌层浸润>50%、肿瘤大小>2cm、淋巴血管间隙浸润(LVSI)和淋巴结转移相关。
- 盆腔污染与FIGO分期或组织学亚型无关联。
局限性
- 腹膜污染是否增加疾病复发风险应在更大样本系列中研究,包括评估复发模式及辅助治疗的潜在影响。
- 在更好地理解子宫切除术中腹膜污染的临床影响之前,有必要采取措施减少腹膜污染。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Malignant peritoneal cytology in endometrial cancer (EC) is not considered an independent adverse prognostic factor for uterine-confined disease and is not a determinant factor in the International Federation of Gynecology and Obstetrics (FIGO) staging system. NCCN Guidelines still recommend obtaining cytologies. The aim of this study was to determine the prevalence of peritoneal cytologic contamination following robotic hysterectomy for EC. METHODS: Peritoneal cytology from the pelvis and diaphragm were obtained at the initiation of surgery, and from the pelvis only at the completion of robotic hysterectomy with sentinel lymph node mapping (SLNM). Cytology specimens were evaluated for the presence of malignant cells. Pre- and post-hysterectomy cytology results were compared, and pelvic contamination was defined as conversion from negative to positive cytology following surgery. RESULTS: 244 patients underwent robotic hysterectomy with SLNM for EC. Pelvic contamination was identified in 32 (13.1%) cases. In multivariate analysis, pelvic contamination was associated with >50% myometrial invasion, tumor size >2 cm, lymphovascular space invasion (LVSI), and lymph node metastasis. There was no association with FIGO stage or histology subtypes. CONCLUSIONS: Malignant peritoneal contamination occurred during robotic surgery for EC. Large lesions (>2 cm), deep invasion (>50%), LVSI, and lymph node metastasis were each independently associated with peritoneal contamination. Whether or not peritoneal contamination increases risk for disease recurrence should be studied in larger series, including an evaluation of patterns of recurrence and the potential impact of adjuvant therapies. Until the clinical impact of peritoneal contamination during hysterectomy for EC is better understood, methods to reduce peritoneal contamination are warranted.
引用
- Gwacham NI, Kilowski KA, Recio FO, et al. Malignant peritoneal cytologic contamination with robotic hysterectomy for endometrial cancer. Gynecol Oncol. 2023. PMID: 37329874. doi:10.1016/j.ygyno.2023.06.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。