三级胎心率判读系统与不良新生儿及母亲结局:系统综述与Meta分析
该研究纳入3项观察性研究、47,648例≥37周单胎,评估分娩前最后30至120分钟胎心率Ⅰ、Ⅱ、Ⅲ类者的不良结局。与Ⅰ类相比,Ⅱ类和Ⅲ类5分钟Apgar评分<7及脐动脉pH<7.00发生率更高,但约98%的Ⅱ类新生儿未发生这些不良结局。
要点
- 分娩前最后30至120分钟胎心率Ⅱ类占72.9%,Ⅲ类仅占0.1%。
- 与Ⅰ类(0.74%)相比,Ⅱ类(1.51%)和Ⅲ类(14.63%)5分钟Apgar评分<7发生率更高。
- 约98%的Ⅱ类胎心率新生儿未发生5分钟Apgar评分<7或脐动脉pH<7.00。
核心结论
- 随着胎心率判读类别升高,5分钟Apgar评分<7和脐动脉pH<7.00的发生率显著增加,但约98%的Ⅱ类新生儿未发生这些不良结局。
- 三级胎心率判读系统对新生儿预后的评估是近似而不精确的。
研究设计与样本
- 系统综述与Meta分析,检索MEDLINE Ovid、Scopus、Embase、CINAHL和Clinicaltrials.gov截至2022年5月。
- 纳入仅限报告足月婴儿胎心率Ⅰ、Ⅱ或Ⅲ类相关结局的观察性研究,最终纳入3篇文献、47,648例≥37周单胎。
- 采用Newcastle-Ottawa量表进行质量评价,使用随机效应模型合并比例及进行头对头比较。
主要发现
- 分娩前最后30至120分钟胎心率分类:Ⅰ类占27.0%,Ⅱ类占72.9%,Ⅲ类占0.1%。
- 与Ⅰ类(0.74%)相比,Ⅱ类(1.51%)和Ⅲ类(14.63%)的5分钟Apgar评分<7发生率更高,OR分别为1.56(95%CI 1.23-1.99)和14.46(95%CI 2.77-75.39)。
- 脐动脉pH<7.00发生率:Ⅰ类与Ⅱ类相近(0.08% vs 0.24%;OR 2.85,95%CI 0.41-19.55,未达统计学显著);Ⅲ类为31.04%,显著高于Ⅰ类(OR 161.56,95%CI 25.18-1036.42)和Ⅱ类(OR 42.29,95%CI 14.29-125.10)。
- 缺氧缺血性脑病发生率:Ⅰ类与Ⅱ类相近(0 vs 0.81%;OR 5.86,95%CI 0.75-45.89,未达统计学显著);Ⅲ类为18.97%,显著高于Ⅰ类(OR 61.43,95%CI 7.49-503.50)。
- 剖宫产率:Ⅰ类13.41%与Ⅱ类11.92%相近(OR 0.87,95%CI 0.72-1.05,未达统计学显著);Ⅲ类14.28%,显著高于Ⅰ类(OR 3.97,95%CI 1.62-9.75),也高于Ⅱ类(OR 4.55,95%CI 1.88-11.01)。
临床怎么用
- 作者认为,三级胎心率判读系统对新生儿预后的评估是近似而不精确的。
局限性
- 仅3篇文献符合纳入标准。
- 一项被评为质量差的研究贡献了82.1%的数据,且未提供Ⅲ类胎心率数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study aimed to evaluate the rate of adverse neonatal or maternal outcomes in parturients with fetal heart rate tracings categorized as I, II or, III within the last 30 to 120 minutes of delivery. DATA SOURCES: The MEDLINE Ovid, Scopus, Embase, CINAHL, and Clinicaltrials.gov databases were searched electronically up to May 2022, using combinations of the relevant medical subject heading terms, keywords, and word variants that were considered suitable for the topic. STUDY ELIGIBILITY CRITERIA: Only observational studies of term infants reporting outcomes of interest with category I, II, or III fetal heart rate tracings were included. STUDY APPRAISAL AND SYNTHESIS METHODS: The coprimary outcome was the rate of either Apgar score <7 at 5 minutes or umbilical artery pH <7.00. Secondary outcomes were divided into neonatal and maternal adverse outcomes. Quality assessment of the included studies was performed using the Newcastle-Ottawa Scale. Random-effect meta-analyses of proportions were used to estimate the pooled rates of each categorical outcome in fetal heart rate tracing category I, II, and III patterns, and random-effect head-to-head meta-analyses were used to directly compare fetal heart rate tracings category I vs II and fetal heart rate tracing category II vs III, expressing the results as summary odds ratio or as mean differences with relative 95% confidence intervals. RESULTS: Of the 671 articles reviewed, 3 publications met the inclusion criteria. Among them were 47,648 singletons at ≥37 weeks' gestation. Fetal heart rate tracings in the last 30 to 120 minutes before delivery were characterized in the following manner: 27.0% of deliveries had category I tracings, 72.9% had category II tracings, and 0.1% had category III tracings. A single study, which was rated to be of poor quality, contributed 82.1% of the data and it did not provide any data for category III fetal heart rate tracings. When compared with category I fetal heart rate tracings (0.74%), the incidence of an Apgar score <7 at 5 minutes were significantly higher among deliveries with category II fetal heart rate tracings (1.51%) (odds ratio, 1.56; 95% confidence interval, 1.23-1.99) and among those with category III tracings (14.63%) (odds ratio, 14.46; 95% confidence interval, 2.77-75.39). When compared with category II tracings, category III tracings also had a significantly higher likelihood of a low Apgar score at 5 minutes (odds ratio, 14.46; 95% confidence interval, 2.77-75.39). The incidence of an umbilical artery pH <7.00 were similar among those with category I and those with category II tracings (0.08% vs 0.24%; odds ratio, 2.85; 95% confidence interval, 0.41-19.55). When compared with category I tracings, the incidence of an umbilical artery pH <7.00 was significantly more common among those with category III tracings (31.04%; odds ratio, 161.56; 95% confidence interval, 25.18-1036.42); likewise, when compared with those with category II tracings, those with category III tracings had a significantly higher likelihood of having an umbilical artery pH <7.00 (odds ratio, 42.29; 95% confidence interval, 14.29-125.10). Hypoxic-ischemic encephalopathy occurred with similar frequency among those with categories I and those with category II tracings (0 vs 0.81%; odds ratio, 5.86; 95% confidence interval, 0.75-45.89) but was significantly more common among those with category III tracings (0 vs 18.97%; odds ratio, 61.43; 95% confidence interval, 7.49-503.50). Cesarean delivery occurred with similar frequency among those with category I (13.41%) and those with category II tracings (11.92%) (odds ratio, 0.87; 95% confidence interval, 0.72-1.05) but was significantly more common among those with with category III tracings (14.28%) (odds ratio, 3.97; 95% confidence interval, 1.62-9.75). When compared with those with category II tracings, cesarean delivery was more common among those with category III tracings (odds ratio, 4.55; 95% confidence interval, 1.88-11.01). CONCLUSION: Although the incidence of an Apgar score <7 at 5 minutes and umbilical artery pH <7.00 increased significantly with increasing fetal heart rate tracing category, about 98% of newborns with category II tracings do not have these adverse outcomes. The 3-tiered fetal heart rate tracing interpretation system provides an approximate but imprecise measurement of neonatal prognosis.
引用
- Zullo F, Di Mascio D, Raghuraman N, et al. Three-tiered fetal heart rate interpretation system and adverse neonatal and maternal outcomes: a systematic review and meta-analysis. Am J Obstet Gynecol. 2023. PMID: 37044237. doi:10.1016/j.ajog.2023.04.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。