文献速递产科

足月产程中宫颈检查使用无菌手套与清洁手套对产妇感染的影响:一项随机试验

Effect of sterile vs clean gloves for cervical checks in labor on maternal infection at term: a randomized trial.
PubMed 文献 · Am J Obstet Gynecol MFM · 2023-03-24

本随机对照试验将163例足月单胎孕妇随机分为无菌手套组(74例)和清洁手套组(89例),比较产程中宫颈检查所用无菌与清洁手套对产时及产后感染率的影响。结果显示两组产时感染(绒毛膜羊膜炎)率分别为5.4%和4.4%,产后感染(子宫内膜炎)率分别为1.3%和2.2%,均无显著差异。作者结论认为清洁手套不增加感染风险,并可能降低机构成本。

要点

  • 足月产程宫颈检查使用清洁手套与无菌手套相比,产时感染率无显著差异(5.4% vs 4.4%,P=1.0)。
  • 产后感染率两组也无显著差异(1.3% vs 2.2%,P=1.0)。
  • 作者认为清洁手套不增加感染风险,并可能降低机构成本。

核心结论

  • 足月产程中宫颈检查使用清洁手套不太可能增加感染风险,并可能在本机构降低高达92.4%的成本,每年节省超过25,000美元。

研究设计与样本

  • 前瞻性随机对照试验,纳入163例足月单胎妊娠且完成研究的参与者,随机分为无菌无粉聚氯乙烯检查手套组(当前常规实践,对照组,74例,45%)或清洁无粉丁腈检查手套组(非无菌,实验组,89例,55%)。

主要发现

  • 无菌手套组4例(5.4%)发生产时感染(绒毛膜羊膜炎),1例(1.3%)发生产后感染(子宫内膜炎)。
  • 清洁手套组4例(4.4%)发生产时感染,2例(2.2%)发生产后感染。
  • 两组产时感染率无显著差异(P=1.0),产后感染率无显著差异(P=1.0),合并感染率(包括绒毛膜羊膜炎和子宫内膜炎)也无显著差异(P=.99)。
  • 合并两组中任何产时或产后感染者(n=11)与无感染者(n=152)相比,前者更可能为未产(P=.01)、孕次更低(P<.01)和产次更低(P<.01)、从首次宫颈检查到分娩时间更长(P=.02)、从胎膜破裂到分娩时间更长(P=.0001)、行剖宫产分娩(P=.0002)以及发生产后出血(P=.001)。
  • 产程更长(P=.02)可能与感染性疾病更相关,而宫颈检查次数(P=.15)相关性较弱。

局限性

  • 样本量计算预计需要300例参与者(对照组感染率10%,实验组20%),但实际感染率远低于预期(无菌手套组5.4%,清洁手套组4.4%)。
  • 因继续研究被认为无望而终止,需要超过29,000例参与者才能显示差异,这在年分娩量约3500例的单一三级转诊中心无法实现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intrapartum infection usually warrants immediate delivery and impacts 5-12% of term pregnancies, with the most commonly identified pathogenic organism being of the Ureaplasma genus. When performing cervical examinations during labor, providers in the United States commonly use sterile gloves, although there are no data currently to support that this practice reduces rates of infection. Furthermore, in nearly all other settings of Gynecologic care, aside from surgery in an operating room, nonsterile gloves are used. Even though the uterus could be sterile in normal pregnancies, the provider performing the cervical examination must traverse the milieu of vaginal bacteria in order to reach the cervix to perform the exam, introducing vaginal microbiota into the uterus regardless of the type of glove used. This prospective randomized controlled study examines whether the type of glove used (sterile vs clean) impacts the rates of intrapartum infection in patients receiving cervical examinations during labor or induction of labor at term.. OBJECTIVE: This study aimed to evaluate if the glove type (sterile vs clean) used for cervical examinations during labor affects the rates of intrapartum and postpartum infection. STUDY DESIGN: This randomized controlled trial assigned eligible and consenting participants to receive cervical examinations during labor with either sterile powder-free polyvinyl chloride examination gloves (current routine practice, control group) or clean powder-free nitrile examination gloves (nonsterile, experimental group). The primary outcome was rates of intrapartum infection (chorioamnionitis). Sample size calculations estimated that 300 participants would be needed with a rate of infection of 10% in the control group and 20% in the experimental group to demonstrate difference between the groups; however, the rates of infection were much lower than expected, at 5.4% and 4.4% in the sterile and clean glove group, respectively. At this point, it was determined futile to continue the study because a sample size of >29,000 participants would be needed, which would not be achievable at a single tertiary care referral center with approximately 3500 deliveries per year. The study was approved by the Eastern Virginia Medical School Institutional Review Board (IRB 21-09-FB-0206), and was registered at ClinicalTrials.gov (identifier NCT05603624; https://clinicaltrials.gov/ct2/show/NCT05603624). RESULTS: A total of 163 participants with singleton pregnancies completed the study; 74 (45%) were randomized to the sterile glove group, and 89 (55%) were randomized to the clean glove group. In the sterile glove group, 4 (5.4%) developed intrapartum infection (chorioamnionitis) and 1 (1.3%) developed postpartum infection (endometritis). In the clean glove group, 4 (4.4%) developed intrapartum infection and 2 (2.2%) developed postpartum infection. There was no significant difference in rates of intrapartum infection (P=1.0) or postpartum infection (P=1.0), or combined rates of infection (including both chorioamnionitis and endometritis; P=.99) between the sterile and the clean glove group. When comparing the participants from both groups who had any intrapartum or postpartum infection (n=11) with those who had no infection (n=152), the former were more likely to be nulliparous (P=.01), have lower gravidity (P<.01) and parity (P<.01), have longer times from first cervical examination to delivery (P=.02), have longer times from rupture of membranes to delivery (P=.0001), undergo cesarean delivery (P=.0002), and experience postpartum hemorrhage (P=.001). Although participants who were in labor for a longer time also likely had more cervical examinations, these data could suggest that duration of labor (P=.02) is more closely associated with infectious morbidity compared with the number of cervical examinations (P=.15). CONCLUSION: Using clean gloves for cervical examinations during labor is unlikely to increase risk of infection, and could reduce cost by up to 92.4% at our institution, saving over $25,000 annually.

来源:Am J Obstet Gynecol MFM,查看原文。版权归原作者所有。

引用

  1. Morshedi B, Strohm S, James H, et al. Effect of sterile vs clean gloves for cervical checks in labor on maternal infection at term: a randomized trial. Am J Obstet Gynecol MFM. 2023. PMID: 36965695. doi:10.1016/j.ajogmf.2023.100931

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。