经阴道指法与窥器引导置入导管球囊促宫颈成熟在经产妇中的随机对照试验
本研究在单家三级大学附属医院纳入足月经产妇(Bishop评分<6)随机分组,比较指法与窥器引导置入Foley导管球囊引产。指法组置入时疼痛视觉模拟评分更低(中位4 vs 7,P<.001)、满意度更高(5 vs 4,P=.01)、操作时间更短(2.1 vs 3.0分钟,P<.001),引产至分娩间隔相似,宫颈成熟与新生儿结局无显著差异。
要点
- 经产妇指法置入Foley球囊置入时疼痛中位VAS评分4分,低于窥器组的7分(P<.001)。
- 指法组操作时间中位2.1分钟,短于窥器组的3.0分钟(P<.001),满意度中位5分高于窥器组4分(P=.01)。
- 两组引产至分娩间隔、宫颈成熟(Bishop评分≥6)及新生儿结局无显著差异。
核心结论
- 经产妇指法置入Foley导管球囊促宫颈成熟比窥器引导置入疼痛更轻、操作更快,且在成功促宫颈成熟方面不劣于窥器引导。
研究设计与样本
- 单家三级大学附属医院开展的随机对照试验,纳入足月经产妇(产次≥1)且Bishop评分<6行引产,随机分为指法置入组与窥器引导Foley导管置入组,行意向性治疗分析。
主要发现
- 指法组与窥器组各分析50例;置入时VAS中位评分指法组4分(范围0-10)vs窥器组7分(范围0-10),P<.001。
- 引产至分娩间隔两组相似。
- 指法组满意度中位评分5分(范围3-5)vs窥器组4分(范围1-5),P=.01。
- 指法组操作时间中位2.1分钟(范围1.4-5.3)vs窥器组3.0分钟(范围1.4-5.0),P<.001。
- 多因素分析中,指法置入(P=.009)与产次增加(P=.001)独立降低VAS评分;宫颈成熟、母体感染率及新生儿结局两组无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Catheter balloon insertion into the maternal uterine cervix is routinely speculum guided; digital insertion has been reported, but it was not found to be more tolerable among nulliparas. OBJECTIVE: In a cohort of multiparas, we aimed to evaluate maternal pain, the induction to delivery interval, and maternal satisfaction with digital insertion vs speculum-guided placement of a Foley catheter balloon for labor induction. STUDY DESIGN: This randomized trial was conducted at a single, tertiary, university-affiliated hospital. The participants were multiparas (parity ≥1) and were admitted at term for labor induction with a Bishop score <6. They were randomized to 2 groups, namely the digital insertion and the speculum-guided Foley catheter insertion groups. An intention-to-treat analysis was performed. The co-primary outcomes were visual analog scale scores (0-10) and induction to delivery intervals. Secondary outcomes were procedure duration, maternal satisfaction, cervical ripening (Bishop score ≥6), delivery within 24 hours, infection rate, and neonatal outcomes. RESULTS: A total of 50 women were analyzed for each study group. For the digitally inserted vs speculum-guided insertion group, the median visual analog scale score at catheter insertion was lower (4; range, 0-10; vs 7; range, 0-10; P<.001), and the induction to delivery interval was similar. For the digitally inserted vs speculum-guided insertion group, the median maternal satisfaction score was greater (5; range 3-5; vs 4; 1-5; P=.01), and the median procedure duration was shorter (2.1; range, 1.4-5.3 minutes vs 3.0; range, 1.4-5.0; P<.001). In the multivariate analysis, digital insertion (P=.009) and increased parity (P=.001) independently decreased the visual analog scale score. Cervical ripening, the maternal infection rate, and the neonatal outcomes did not differ significantly between the groups. CONCLUSION: Digital insertion of a Foley catheter balloon for cervical ripening in multiparas is less painful and quicker than speculum-guided insertion. It is also not inferior in terms of successful cervical ripening.
引用
- Abu Shqara R, Nakhleh Francis Y, Haj H, et al. Digital vs speculum-guided catheter balloon insertion for cervical ripening in multiparas: a randomized controlled trial. Am J Obstet Gynecol MFM. 2023. PMID: 36972835. doi:10.1016/j.ajogmf.2023.100943
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。