文献速递妇科

二维经阴道超声征象预测子宫腺肌病的准确性:前瞻性多中心研究

Accuracy of ultrasound signs on two-dimensional transvaginal ultrasound in prediction of adenomyosis: prospective multicenter study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2023-01-01

本研究为前瞻性多中心研究,纳入202例计划行腹腔镜子宫切除术的患者,在九个专精子宫内膜异位症诊治的中心以标准化二维经阴道超声评估九种子宫腺肌病超声征象,并与子宫切除术后组织学对比。结果显示,使用全部征象预测腺肌病的准确率为63.4%(阳性预测值71.5%,阴性预测值48.6%,敏感度71.5%,特异度48.6%);异质性肌层、肌层囊肿、子宫内膜下微囊肿和肌层高回声斑点作为单一征象准确率最高(55.7%–62.1%),三者联合的特异度(86.1%)高于任一单一征象(35.2%–81.7%)。子宫增大和不对称的敏感度(分别为60.8%和52.3%)与特异度(分别为41.7%和49.3%)均较低。

要点

  • 二维经阴道超声使用全部征象预测腺肌病的准确率为63.4%,敏感度和特异度均为71.5%和48.6%。
  • 异质性肌层、肌层囊肿、子宫内膜下微囊肿和肌层高回声斑点作为单一征象准确率最高(55.7%–62.1%)。
  • 子宫内膜下微囊肿、肌层囊肿和异质性肌层三者联合的特异度为86.1%,高于任一单一征象(35.2%–81.7%)。

核心结论

  • 异质性肌层、肌层囊肿、子宫内膜下微囊肿和肌层高回声斑点在检测子宫腺肌病时准确率最高,而子宫增大和不对称导致较高的假阳性和假阴性结果。
  • 包含最准确征象的超声特征组合可提高特异度。

研究设计与样本

  • 前瞻性多中心研究,纳入202例计划行腹腔镜子宫切除术的患者,在九个专精子宫内膜异位症诊治的中心接受标准化二维经阴道超声检查。
  • 二维经阴道超声检查包括九种典型子宫腺肌病超声特征:异质性肌层、肌层线状条纹、肌层囊肿、子宫内膜下微囊肿、肌层不对称增厚、子宫增大、问号征、结合带增厚和肌层高回声斑点。
  • 超声检查结果与子宫切除术后的组织学结果进行对比,分析九种超声征象及其组合的诊断可靠性,以及合并肌瘤对结果准确性的影响。

主要发现

  • 组织病理学检查显示130例患者(64.4%)存在子宫腺肌病。
  • 使用全部征象的二维经阴道超声预测子宫腺肌病的准确率为63.4%(阳性预测值71.5%,阴性预测值48.6%,敏感度71.5%,特异度48.6%)。
  • 异质性肌层、肌层囊肿、子宫内膜下微囊肿和肌层高回声斑点作为单一超声征象预测子宫腺肌病的准确率最高(55.7%–62.1%)。
  • 最准确超声征象的组合(子宫内膜下微囊肿、肌层囊肿和异质性肌层)特异度为86.1%,高于这三种单一标志物的35.2%–81.7%。
  • 子宫增大和不作为单一超声征象的敏感度分别为60.8%和52.3%,特异度分别为41.7%和49.3%。

关键数值与推荐

  • 使用全部征象的二维经阴道超声预测子宫腺肌病:准确率63.4%,阳性预测值71.5%,阴性预测值48.6%,敏感度71.5%,特异度48.6%。
  • 单一征象准确率最高者:异质性肌层、肌层囊肿、子宫内膜下微囊肿和肌层高回声斑点,准确率55.7%–62.1%。
  • 子宫内膜下微囊肿、肌层囊肿和异质性肌层联合:特异度86.1%,高于单一征象的35.2%–81.7%。
  • 子宫增大:敏感度60.8%,特异度41.7%;子宫不对称:敏感度52.3%,特异度49.3%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Two-dimensional (2D) transvaginal ultrasound (TVS) is an accessible and cost-effective diagnostic tool for the detection of adenomyosis. Different ultrasound features related to adenomyosis have been described, but the predictive value of each ultrasound sign and their combinations requires further investigation. We aimed to analyze the accuracy of 2D-TVS and describe possible combinations of ultrasound signs with a high predictive value in the diagnosis of adenomyosis. METHODS: This was a prospective multicenter study of patients scheduled for laparoscopic hysterectomy who had been examined using standardized 2D-TVS at nine expert centers specializing in the diagnosis and treatment of endometriosis. 2D-TVS examination included nine typical adenomyosis ultrasound features, comprising heterogeneous myometrium, myometrial linear striations, myometrial cysts, subendometrial microcysts, asymmetrical myometrial thickening, uterine enlargement, the 'question mark sign', thickening of the junctional zone and hyperechoic myometrial spots, in order to predict or exclude the presence of adenomyosis. Ultrasound examination results were compared with histology after hysterectomy. The diagnostic reliability of the nine ultrasound signs and their combinations, and the influence of concurrent fibroids on the accuracy of the results, were analyzed. RESULTS: A total of 202 patients were enrolled into the study. Histopathological examination revealed adenomyosis in 130 patients (64.4%). The accuracy of prediction of adenomyosis by 2D-TVS examination using all signs was 63.4% (positive predictive value, 71.5%; negative predictive value, 48.6%; sensitivity, 71.5%; specificity, 48.6%). Heterogeneous myometrium, myometrial cysts, subendometrial microcysts and hyperechoic myometrial spots showed the highest accuracy (55.7-62.1%) as individual ultrasound signs for the prediction of adenomyosis. The combination of the most accurate ultrasound signs (subendometrial microcysts, myometrial cysts and heterogeneous myometrium) improved the specificity of prediction (86.1%) when compared with that of these three single markers (35.2-81.7%). Uterine enlargement and asymmetry showed both low sensitivity (60.8% and 52.3%, respectively) and specificity (41.7% and 49.3%, respectively) as individual sonographic signs. CONCLUSIONS: Heterogeneous myometrium, myometrial cysts, subendometrial microcysts and hyperechoic myometrial spots showed the highest accuracy for the detection of adenomyosis in this study, while uterine enlargement and asymmetry led to high false-positive and false-negative results. A combination of ultrasound features including the most accurate signs increases specificity. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Krentel H, Keckstein J, Füger T, et al. Accuracy of ultrasound signs on two-dimensional transvaginal ultrasound in prediction of adenomyosis: prospective multicenter study. Ultrasound Obstet Gynecol. 2023. PMID: 36920431. doi:10.1002/uog.26197

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。