文献速递产科

妊娠患者机器人辅助经阔韧带腹部环扎术的技巧与要点

Tips and Tricks for Robotic-Assisted Trans-Broad Ligament Abdominal Cerclage in Pregnant Patients.
PubMed 文献 · J Minim Invasive Gynecol · 2023-02-09

本文通过分步演示与解说视频,展示机器人辅助经阔韧带开窗行腹部环扎术的操作技巧,旨在降低妊娠期手术风险。患者为32岁孕8产2活3,既往19周和23周妊娠丢失及1次阴道环扎失败,孕13周5天接受手术。作者已完成5例该技术手术,孕周9至14周,认为该技术可能可行且安全,但需进一步研究。

要点

  • 经阔韧带开窗可清晰暴露双侧子宫血管,减少误伤大血管风险。
  • 该技术可避免盲穿针损伤羊膜囊导致胎膜破裂和妊娠丢失。
  • 作者已完成5例妊娠患者手术,孕周9至14周,认为可能可行且安全。

核心结论

  • 机器人辅助经阔韧带开窗腹部环扎术为希望降低风险的外科医生提供了一种可能可行且安全的技术,但需进一步研究。

研究设计与样本

  • 分步演示与解说视频,学术三级医院,患者为32岁孕8产2活3,既往19周和23周妊娠丢失及1次阴道环扎失败,孕13周5天就诊。
  • 作者已完成5例该技术手术,妊娠患者孕周9至14周。

主要发现

  • 术中使用单极剪刀分离子宫前壁至前腹壁的致密粘连带,助手行阴道指检协助形成膀胱瓣。
  • 用单极剪刀将膀胱从子宫下段和子宫分离,钝性分离和单极剪刀进一步骨骼化并前侧暴露双侧子宫血管。
  • 右侧阔韧带开窗,子宫血管进一步分离并侧移,在子宫血管内侧、宫颈内口水平形成小窗,Mersilene带从前向后穿过。
  • 左侧同法开窗,Mersilene带从后向前穿过,环扎带完全环绕宫颈内口水平、子宫血管内侧。
  • 环扎带两端轻柔牵拉确保平铺于子宫前壁,于12点位置前方以适当张力打结,2-0丝线缝合于带尾固定防止松结。

临床怎么用

  • 作者认为该技术可能可行且安全,可供希望降低风险的外科医生参考。

局限性

  • 原文结论指出需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY OBJECTIVE: To demonstrate the surgical techniques for improving safety in robotic-assisted abdominal cerclage via broad ligament window dissection. DESIGN: Stepwise demonstration with narrated video footage. SETTING: An academic tertiary care hospital. Our patient is a 32-year-old G8P2143, with a history of pregnancy loss at 19 and 23 weeks and 1 failed vaginal cerclage, presented to us at 13 weeks and 5 days for abdominal cerclage. We have completed a total of 5 successful procedures with this technique on pregnant patients ranging from 9 to 14 weeks. INTERVENTIONS: Abdominal cerclage during pregnancy can be very risky and challenging to perform; however, it offers an increased success rate for continuing pregnancy [1]. Excessive bleeding and the rupture of membrane during the procedure could lead to pregnancy loss and a failed abdominal cerclage [2,3]. Therefore, seeking a feasible and safer technique would be preferable for the surgeons to decrease surgical risk and complications. We have developed a trans-broad ligament technique that would allow for the bilateral uterine vessels to be clearly exposed, thereby reducing the possibility of accidental damage to a major vessel and eliminating the risk of blind needle placement piercing through the amniotic sac resulting in rupture of membrane and subsequent pregnancy loss [4,5]. A dense adhesion band from the anterior uterus to the anterior abdominal wall was carefully taken down using the monopolar scissors. The assistant gently performed a digital vaginal examination to assist with the creation of a bladder flap. The bladder was carefully dissected off the lower uterine segment and uterus using the monopolar scissors. Bilateral uterine vessels were further skeletonized and exposed anteriorly using blunt dissection and the monopolar scissors. On the right, a window was created in the broad ligament using the monopolar scissors. The right uterine vessels were then further dissected and lateralized, creating a small window medial to the uterine vessels at the level of the internal cervical os. The mersilene tape was guided through the window from anterior to posterior. In a similar fashion, a window was created on the left; the mersilene tape was then guided from posterior to anterior. The mersilene tape was completely placed around the cervix circumferentially at the level of the internal cervical os, medial to the uterine vessels. Both ends of the mersilene tape were then pulled gently, while ensuring that the tape was lying flat on the anterior of the uterus. The tape was then tied anteriorly at the 12 o'clock position in an appropriate tension. A 2-0 silk was then sutured to the tails of the tape to ensure that it would remain in the correct location and prevent the loosening of the knot of mersilene tape. The pelvis was copiously irrigated, and hemostasis was assured. The fetal heart rate was 126 bpm, and patient was discharge next day. A healthy baby, 6 pounds 14 ounces, was delivered by cesarean section at 36 weeks 5 days because of early contractions and pain (Supplemental Appendix 1-4). CONCLUSION: Robotic-assisted abdominal cerclage via broad ligament window dissection offers a possibly feasible and safe technique for surgeons seeking to reduce risks, although further research is needed.

来源:J Minim Invasive Gynecol,查看原文。版权归原作者所有。

引用

  1. Guan Z, Zhang C, Thigpen B, et al. Tips and Tricks for Robotic-Assisted Trans-Broad Ligament Abdominal Cerclage in Pregnant Patients. J Minim Invasive Gynecol. 2023. PMID: 36764647. doi:10.1016/j.jmig.2023.02.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。