文献速递妇科

吲哚菁绿辅助逆行输尿管松解术在机器人经阴道自然腔道内镜手术中处理IV期子宫内膜异位症伴封闭直肠子宫陷凹的应用

Indocyanine Green-Assisted Retrograde Ureterolysis in Robotic Transvaginal NOTES for the Management of Stage IV Endometriosis with Obliterated Cul-de-sac.
PubMed 文献 · J Minim Invasive Gynecol · 2023-02-09

本文通过分步演示视频展示在机器人辅助经阴道自然腔道内镜手术(vNOTES)子宫切除术中,使用吲哚菁绿(ICG)标记输尿管解剖标志,以安全完成IV期子宫内膜异位症伴封闭直肠子宫陷凹的病灶切除。患者为38岁女性,术后一天出院,疼痛轻微。作者认为该技术可行且安全。

要点

  • ICG辅助输尿管标记有助于在vNOTES手术初期快速识别输尿管。
  • 逆行输尿管松解术指从子宫动脉水平向髂总动脉分叉处解剖输尿管。
  • 该技术或可降低输尿管和肠管损伤风险,使vNOTES用于复杂病例成为可能。

核心结论

  • 机器人辅助vNOTES子宫切除术联合深部浸润型子宫内膜异位症切除,在封闭直肠子宫陷凹病例中采用ICG辅助输尿管标记是可行且安全的。
  • 输尿管的独特绿色标记为输尿管解剖提供了显著标志,有助于避免输尿管和肠管损伤,从而使vNOTES手术有可能用于挑战性病例。

研究设计与样本

  • 研究设计为分步演示并附解说视频。
  • 设置:学术三级护理医院。
  • 患者:38岁,孕4产1(G4P1031),因腺肌症和子宫肌瘤致子宫增大伴症状,后子宫与左侧子宫骶韧带致密粘连。

主要发现

  • 使用ICG萤火虫技术可在机器人经腹部子宫内膜异位症手术中快速识别并安全解剖输尿管。
  • 在vNOTES手术中,采用膀胱镜放置输尿管导管,向右输尿管注入5 cc ICG,左侧同样操作。
  • 双侧输尿管在子宫动脉水平使用萤火虫模式识别并从双侧盆侧壁解剖出来,输尿管易于从子宫分离。
  • 患者术后一天出院,诉轻微疼痛。

关键数值与推荐

  • vNOTES逆行输尿管松解术的概念:从子宫动脉水平向髂总动脉分叉处解剖输尿管。
  • 右侧输尿管注入5 cc ICG,左侧同样操作。

临床怎么用

  • 作者认为,在封闭直肠子宫陷凹病例中,ICG辅助输尿管标记可使机器人辅助vNOTES子宫切除术联合深部浸润型子宫内膜异位症切除可行且安全。
  • 作者指出,输尿管的绿色标记有助于输尿管解剖并避免输尿管和肠管损伤,使vNOTES手术有可能用于挑战性病例。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY OBJECTIVE: To explore the use of indocyanine green (ICG) in highlighting ureteral anatomical landmarks for the successful and safe execution of robotic-assisted transvaginal NOTES hysterectomy with resection of deeply infiltrated endometriosis. DESIGN: Stepwise demonstration with narrated video footage. SETTING: An academic tertiary care hospital. Our patient is a 38-year-old G4P1031 with a symptomatic enlarged uterus secondary to adenomyosis and uterine myomas, dense adhesions between the posterior uterus, and left uterosacral ligament. INTERVENTIONS: Stage IV endometriosis with obliterated cul-de-sac is a challenging procedure in the surgical management of endometriosis. Ureterolysis is the key step to performing this surgery successfully and safely; however, the routine dissection of ureters from the sacral promontory level to the uterine artery is challenging in obliterated cul-de-sacs with pelvic side wall adhesions with the proximal ureter at greatest risk [1-4]. Using the ICG firefly technique allowed us to rapidly identify and safely dissect the ureter through robotic transabdominal endometriosis surgery [5,6]. The angle of approach in transvaginal NOTES surgery for hysterectomy with obliterated cul-de-sac endometriosis leads to far more difficulty in identifying the ureter at the beginning of surgery [3]. Therefore, an obliterated cul-de-sac was associated with a potentially increased risk of ureteral injury and bowel injury. We used ICG to help identify the ureter at the beginning of the case leading to reducing the risk of surgical complication, in which the concept of ureterolysis from the level of the uterine artery to the bifurcation of common iliac vessels in vNOTES surgery will be referred to as "vNOTES retrograde ureterolysis." With the cystoscope in place, a ureteral catheter was inserted into the right ureter and 5 cc of ICG was injected, and the same procedure was done on the left [1,5]. Bovie electrosurgical device was used to incise circumferentially around the cervix. The bladder was dissected off the pubovesical cervical fascia anteriorly and posteriorly with a combination of the Bovie as well as blunt and sharp dissection. Bilateral uterosacral and cardinal ligaments, as well as uterine arteries, were then clamped, transected with Mayo scissors, and secured. Entry into the anterior cul-de-sac was completed, and a stitch using 0 vicryl was used to tag the anterior peritoneum to the anterior vaginal cuff. Posterior entry was attempted unsuccessfully. The Gelpoint mini device was then placed, and the Da Vinci XI robot was docked. Bilateral ureters were identified and dissected out of bilateral pelvic sidewalls using the firefly mode at the level of the uterine artery. The ureters were easily dissected away from the uterus. The left broad ligament was then cauterized and transected using the vessel sealer. The plane between the uterus and the rectum was identified laterally, and the rectum was taken down from the uterus from the right to the left side. Bilateral broad ligaments were then cauterized and transected using the vessel sealer, followed by cauterization and transection of the round ligaments, utero-ovarian ligaments, and mesosalpinx bilaterally. The vaginal cuff angles were secured with a figure-of-eight stitch of 0 vicryl, and the vaginal cuff was then closed in a running fashion with 0 V-Loc. The patient was discharged in one day with reports of minimal pain (Videos 1-3). CONCLUSION: Robotic-assisted NOTES hysterectomy with deeply infiltrated endometriosis resection is feasible and safe with ICG-assisted ureteral labeling in a case of obliterated cul-de-sac. The unique green color labeling of ureters offers a prominent landmark in assisting the ureteral dissection while avoiding ureteral and bowel injury, resulting in the possibility of using vNOTES surgery in challenging cases.

来源:J Minim Invasive Gynecol,查看原文。版权归原作者所有。

引用

  1. Guan X, Guan Z, Sunkara S, et al. Indocyanine Green-Assisted Retrograde Ureterolysis in Robotic Transvaginal NOTES for the Management of Stage IV Endometriosis with Obliterated Cul-de-sac. J Minim Invasive Gynecol. 2023. PMID: 36764648. doi:10.1016/j.jmig.2023.02.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。