文献速递产科母胎医学

双胎中较小的头臀长推导预产期是否更优?较小与较大双胎头臀长推导预产期下生长受限发生率的比较

Is bigger better? A comparison of growth restriction rates using the crown-rump length derived due date from the smaller versus larger twin.
PubMed 文献 · Am J Obstet Gynecol MFM · 2023-01-19

这项为期10年的回顾性队列研究纳入2所机构中辅助生殖技术受孕的双绒毛膜双胎,比较分别用较小与较大双胎头臀长推导的预产期诊断早发和晚发胎儿生长受限的准确性。结果显示,较小头臀长推导的预产期更接近真实发生率,但漏诊率更高,早发和晚发生长受限的相对风险分别为1.77和1.22。

要点

  • 较小头臀长推导预产期在32周前漏诊2.5%的生长受限病例,较大头臀长漏诊0.6%。
  • 32周后较小头臀长漏诊1.8%,较大头臀长漏诊0%。
  • 较小头臀长推导预产期漏诊生长受限的相对风险早发为1.77、晚发为1.22。

核心结论

  • 使用较小双胎头臀长推导的预产期能更准确地检出胎儿生长受限,但代价是漏诊率更高。

研究设计与样本

  • 为期10年的回顾性队列研究,纳入2所机构中辅助生殖技术受孕、无畸形的双绒毛膜双胎妊娠,共筛查176例。
  • 81例在24至<32周妊娠接受了胎儿生长超声检查,58例在≥32周妊娠接受了胎儿生长超声检查。
  • 使用Hadlock公式分别基于较小和较大头臀长推导的预产期计算生长受限发生率,并与辅助生殖技术确定的真实预产期比较,采用Fisher精确检验。

主要发现

  • 在24至<32周和≥32周两个孕周范围内,3种预产期策略下胎儿生长受限发生率差异均有统计学意义(P<.001),较小头臀长推导的预产期更接近真实发生率。
  • 32周前,较小头臀长推导的预产期漏诊2.5%的生长受限病例,较大头臀长漏诊0.6%,假阳性率和误差率分别为1.2%和3.7%以及5.5%和6.2%。
  • 32周后,较小头臀长推导的预产期漏诊1.8%的病例,较大头臀长漏诊0%,假阳性率和误差率分别为2.6%和4.4%以及5.3%和5.3%。
  • 使用较小头臀长推导的预产期漏诊生长受限的相对风险,早发为1.77,晚发为1.22。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although the smaller twin's crown-rump length is most accurate in establishing the estimated due date in dichorionic gestations, societal guidelines favor the use of the larger twin measurements based on concern for missing a diagnosis of fetal growth restriction. OBJECTIVE: This study aimed to compare the accuracy of the diagnosis of early- and late-onset fetal growth restriction in dichorionic twin gestations conceived by assisted reproductive technology using the estimated due date as established by the crown-rump length of the smaller vs larger twin. STUDY DESIGN: This was a 10-year retrospective cohort study of nonanomalous, dichorionic gestations conceived with assisted reproductive technology at 2 institutions. The incidence of early-onset (<32 weeks of gestation) and late-onset (≥32 weeks of gestation) growth restriction derived from the Hadlock formula using the smaller and larger crown-rump length estimated due date was compared with the true estimated due date by assisted reproductive technology. Statistical significance was determined using the Fisher exact test. The incidence of missed fetal growth restriction cases, false-positive rate, and error were calculated along with the relative risk for a missed diagnosis using the smaller crown-rump length. RESULTS: A total of 176 subjects were screened: 81 had a fetal growth ultrasound at 24 to <32 weeks of gestation, and 58 had a fetal growth ultrasound at ≥32 weeks of gestation. There was a significant difference in the incidence of fetal growth restriction using the 3 dating strategies in both gestational age ranges (P<.001) with the smaller crown-rump length estimated due date more closely approximating the true rate. Before 32 weeks of gestation, the smaller crown-rump length estimated due date missed 2.5% of fetal growth restriction cases, whereas the larger crown-rump length estimated due date missed 0.6% of fetal growth restriction cases, with false-positive and error rates of 1.2% and 3.7% and 5.5% and 6.2%, respectively. After 32 weeks of gestation, the smaller crown-rump length estimated due date missed 1.8% of cases, whereas the larger crown-rump length estimated due date missed 0% of cases, with false-positive and error rates of 2.6% and 4.4% and 5.3% and 5.3%, respectively. The relative risk for a missed diagnosis of fetal growth restriction using the smaller crown-rump length estimated due date was 1.77 for early-onset growth restriction and 1.22 for late-onset growth restriction. CONCLUSION: Using the estimated due date derived from the smaller twin led to a more accurate detection of fetal growth restriction at a cost of a higher missed diagnosis rate.

来源:Am J Obstet Gynecol MFM,查看原文。版权归原作者所有。

引用

  1. DeYoung TH, Stortz SK, Riffenburgh RH, et al. Is bigger better? A comparison of growth restriction rates using the crown-rump length derived due date from the smaller versus larger twin. Am J Obstet Gynecol MFM. 2023. PMID: 36682454. doi:10.1016/j.ajogmf.2023.100869

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。