文献速递产科母胎医学

胎动减少——超声识别高危胎儿并预防死产的效用较差

Decreased fetal movements-the utility of ultrasound to identify infants at risk and prevent stillbirth is poor.
PubMed 文献 · Am J Obstet Gynecol MFM · 2022-10-22

该回顾性队列研究在2017至2020年于布里斯班Mater Mothers医院开展,采用倾向性评分匹配比较孕28周后胎动减少的单胎非畸形妊娠与孕周匹配对照的异常超声参数。主要复合结局在两组间无显著差异(20.2% vs 21.3%;P=.42),胎动减少组检出30例新发小于胎龄儿,需扫描48例检出1例;多次胎动减少者临产前末次扫描复合结局频率较高(13.0% vs 5.4%),但两组临床结局无显著差异。结论认为胎动减少孕妇的超声异常并未增加。

要点

  • 胎动减少组与对照组主要复合超声异常结局无显著差异(20.2% vs 21.3%;P=.42)。
  • 胎动减少组检出30例新发小于胎龄儿,需扫描48例检出1例。
  • 多次胎动减少者临产前末次扫描复合结局频率较高(13.0% vs 5.4%),但临床结局无显著差异。

核心结论

  • 与对照组相比,胎动减少孕妇的超声异常并未增加。

研究设计与样本

  • 回顾性队列研究,在布里斯班Mater Mothers医院于2017年至2020年开展,采用倾向性评分匹配分析。
  • 研究纳入孕28周后出现胎动减少的单胎非畸形妊娠孕妇,匹配后胎动减少组1466例、对照组2207例。

主要发现

  • 主要复合结局发生率在胎动减少组与对照组间无显著差异(20.2% vs 21.3%;P=.42)。
  • 胎动减少组检出30例新发小于胎龄儿,需扫描48例检出1例。
  • 多次胎动减少孕妇临产前末次扫描的复合结局频率较高(13.0% vs 5.4%)。
  • 两组临床结局无显著差异。

关键数值与推荐

  • 主要复合结局包括:脐动脉搏动指数>95百分位、大脑中动脉搏动指数<5百分位、脑胎盘比<10百分位、估测胎儿体重<相应孕周10百分位、大脑中动脉收缩期峰值流速>1.5倍中位数、羊水最大垂直暗区<2 cm或>8 cm。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Despite a paucity of evidence, it is widely accepted that a perceived reduction in fetal movements is associated with an increased risk of stillbirth and poor obstetrical outcome. Consequently, many international guidelines recommend urgent ultrasound assessment of fetal well-being in women presenting with decreased fetal movements. OBJECTIVE: This study aimed to compare rates of abnormal ultrasound findings reflective of fetal compromise between women presenting with decreased fetal movements and gestation-matched controls in the third trimester. STUDY DESIGN: This was a retrospective cohort study performed at the Mater Mothers' Hospital in Brisbane between 2017 and 2020. We undertook propensity score matching analysis comparing abnormal ultrasound parameters in women with singleton, nonanomalous pregnancies presenting with decreased fetal movements after 28 weeks' gestation. The primary outcome was a composite of any abnormal scan parameter: umbilical artery pulsatility index >95th centile, middle cerebral artery pulsatility index <5th centile, cerebroplacental ratio <10th centile, estimated fetal weight <10th centile for gestation, middle cerebral artery peak systolic velocity >1.5 multiples of the median, or deepest vertical pocket of amniotic fluid <2 or >8 cm. RESULTS: After propensity score matching, the study cohort comprised 1466 cases and 2207 controls. The rate of the primary composite outcome was not significantly different between the 2 cohorts (20.2% vs 21.3%; P=.42). There were 30 new cases of small-for-gestational-age detected in the decreased fetal movements cohort, giving a number needed to scan of 48 in the decreased fetal movements group to detect 1 case of small-for-gestational-age. However, the frequency of the composite outcome was higher (13.0% vs 5.4%) at the final scan before birth in women with multiple decreased fetal movement presentations. Despite this, there was no significant difference in clinical outcomes between the 2 cohorts. CONCLUSION: Ultrasound abnormalities are not increased in women with decreased fetal movements compared with controls.

来源:Am J Obstet Gynecol MFM,查看原文。版权归原作者所有。

引用

  1. Turner JM, Cincotta R, Chua J, et al. Decreased fetal movements-the utility of ultrasound to identify infants at risk and prevent stillbirth is poor. Am J Obstet Gynecol MFM. 2022. PMID: 36280144. doi:10.1016/j.ajogmf.2022.100782

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。