预测双胎输血综合征胎儿镜激光凝固术后双胎存活
这项回顾性研究纳入2012至2021年两个大学附属三级胎儿中心的537例单绒毛膜双羊膜囊双胎妊娠合并双胎输血综合征(TTTS)并接受胎儿镜激光凝固术(FLP)的病例,采用随机森林机器学习算法构建预测模型,发现供血儿估测胎儿体重(EFW)低于第10百分位、双胎间EFW差异大于25%、前壁胎盘及供血儿脐动脉、静脉导管和大脑中动脉搏动指数异常共6个变量可用于预测分娩后30天双胎存活,模型曲线下面积为0.916(95%CI,0.887-0.946)。
要点
- 双胎存活组供血儿EFW低于第10百分位比例低于非双胎存活组(56.4% vs 69.4%,P=0.004)。
- 双胎存活组双胎间EFW差异大于25%比例低于非双胎存活组(40.8% vs 56.5%,P=0.001)。
- 预测模型纳入诊断时6个变量,曲线下面积0.916(95%CI,0.887-0.946)。
核心结论
- 开发了一个预测单绒毛膜双胎妊娠TTTS接受FLP后双胎存活的模型,纳入诊断时6个变量,曲线下面积0.916(95%CI,0.887-0.946)。
- 作者认为该临床适用工具可能改善治疗计划和患者咨询。
研究设计与样本
- 回顾性研究,数据来自两个大学附属三级胎儿中心2012至2021年收集的病例。
- 队列纳入接受FLP的单绒毛膜双羊膜囊双胎妊娠合并TTTS,共537例。
- 以分娩后30天存活情况分层,双胎存活346例(64.4%)与单胎或无存活191例(35.6%)比较。
- 采用随机森林机器学习算法构建预测模型,计算各参数相对重要性值,并用留出法检查过拟合。
主要发现
- 单因素分析显示两组人口学参数无差异。
- 诊断时双胎存活组供血儿EFW低于第10百分位比例低于非双胎存活组(56.4% vs 69.4%,P=0.004)。
- 双胎存活组双胎间EFW差异大于25%比例低于非双胎存活组(40.8% vs 56.5%,P=0.001)。
- 双胎存活组前壁胎盘比例低于非双胎存活组(40.5% vs 50.0%,P=0.034)。
- 两组多普勒表现差异显著:双胎存活组供血儿脐动脉和静脉导管PI大于第95百分位比例较低,大脑中动脉PI小于第5百分位比例较低。
关键数值与推荐
- 预测模型纳入6个变量:供血儿EFW低于第10百分位、双胎间EFW差异大于25%、前壁胎盘及供血儿脐动脉、静脉导管和大脑中动脉PI异常。
- 模型曲线下面积0.916(95%CI,0.887-0.946)。
临床怎么用
- 作者认为该模型是临床适用工具,可能改善治疗计划和患者咨询。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To develop a model based on factors available at the time of diagnosis of twin-twin transfusion syndrome (TTTS) for predicting the probability of dual twin survival following fetoscopic laser photocoagulation (FLP) using a machine-learning algorithm. METHODS: This was a retrospective study of data collected at two university-affiliated tertiary fetal centers between 2012 and 2021. The cohort included monochorionic diamniotic twin pregnancies complicated by TTTS that underwent FLP. Data were stratified based on survival 30 days after delivery, and cases with dual survival were compared to those without dual survival. A random forest machine-learning algorithm was used to construct a prediction model, and the relative importance value was calculated for each parameter that presented a statistically significant difference between the two study groups and was included in the model. The holdout method was applied to check overfitting of the random forest algorithm. A prediction model for dual twin survival 30 days after delivery was presented based on the test set. RESULTS: The study included 537 women with monochorionic diamniotic twin pregnancy, of whom 346 (64.4%) had dual twin survival at 30 days after delivery and were compared with 191 (35.6%) cases that had one or no survivors. Univariate analysis demonstrated no differences in demographic parameters between the groups. At the time of diagnosis, the dual-survival group had lower rates of estimated fetal weight (EFW) < 10th centile for gestational age in the donor twin (56.4% vs 69.4%; P = 0.004), intertwin EFW discordance > 25% (40.8% vs 56.5%; P = 0.001) and anterior placenta (40.5% vs 50.0%; P = 0.034). Comparison of Doppler findings between the two groups demonstrated significant differences in the donor twin, with a lower rate of pulsatility index (PI) > 95th centile in the umbilical artery and ductus venosus and a lower rate of PI < 5th centile in the fetal middle cerebral artery in the dual-survival group. Relative importance values for each of these six parameters were calculated, allowing the construction of a prediction model with an area under the receiver-operating-characteristics curve of 0.916 (95% CI, 0.887-0.946). CONCLUSIONS: We developed a predictive model for dual survival in monochorionic twin pregnancies following FLP for TTTS, which incorporates six variables obtained at the time of diagnosis of TTTS, including donor EFW < 10th centile, intertwin EFW discordance > 25%, anterior placenta and abnormal PI in the umbilical artery, ductus venosus and middle cerebral artery of the donor twin. This clinically applicable tool may improve treatment planning and patient counseling. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Krispin E, Mustafa HJ, Espinoza J, et al. Prediction of dual survival following fetoscopic laser photocoagulation for twin-twin transfusion syndrome. Ultrasound Obstet Gynecol. 2023. PMID: 36191157. doi:10.1002/uog.26089