文献速递产科

即时检测设备诊断产科大出血低纤维蛋白原血症有效性的比较回顾性研究:干式血液学与血栓弹力图对比

Comparative retrospective study on the validity of point-of-care testing device for massive obstetrical hemorrhage: dry hematology vs thromboelastography.
PubMed 文献 · Am J Obstet Gynecol MFM · 2022-10-20

本研究为单中心回顾性研究,纳入126例未开始治疗的产科大出血病例,比较干式血液学与血栓弹力图在即时检测中诊断低纤维蛋白原血症的准确性。干式血液学纤维蛋白原值与Clauss法呈强正相关且诊断准确性高,但存在较多高于100 mg/dL的残差且分布不均。血栓弹力图的几个参数与Clauss法也呈强正相关,与干式血液学在相关性和诊断准确性上无显著差异。

要点

  • 干式血液学测得的纤维蛋白原值与Clauss法强正相关,诊断低纤维蛋白原血症准确性高。
  • 干式血液学存在较多高于100 mg/dL的残差且分布不均。
  • 血栓弹力图参数与Clauss法强正相关,与干式血液学在相关性和诊断准确性上无显著差异。

核心结论

  • 干式血液学与血栓弹力图诊断低纤维蛋白原血症的准确性相当,结果均与Clauss法测得的纤维蛋白原值相关性良好。

研究设计与样本

  • 单中心回顾性研究,纳入126例未开始治疗的产科大出血病例,比较干式血液学与血栓弹力图检测纤维蛋白原值与Clauss法的相关性及诊断低纤维蛋白原血症的准确性。

主要发现

  • 干式血液学纤维蛋白原值与Clauss法呈强正相关,诊断低纤维蛋白原血症准确性高,但存在较多高于100 mg/dL的残差且分布不均。
  • 血栓弹力图的最大振幅枸橼酸化功能性纤维蛋白原、振幅-10枸橼酸化快速血栓弹力图和振幅-10枸橼酸化功能性纤维蛋白原与Clauss法纤维蛋白原值呈强正相关,与干式血液学在相关性和诊断准确性上无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Early recognition of hypofibrinogenemia and prompt initiation of transfusion therapy in patients with massive obstetrical hemorrhage can improve prognosis. There are reports on the usefulness of point-of-care testing, which provides quicker test results compared with fibrinogen measurements using the conventional Clauss method. OBJECTIVE: This study aimed to compare and investigate the diagnostic accuracy of dry hematology and thromboelastography in point-of-care testing for the diagnosis of hypofibrinogenemia. STUDY DESIGN: A single-center, retrospective study of 126 massive obstetrical hemorrhage cases with point-of-care testing before treatment was initiated. The correlation of fibrinogen values with the Clauss method and the diagnostic accuracy for hypofibrinogenemia were compared between dry hematology and thromboelastography. RESULTS: Fibrinogen value in dry hematology showed a strong positive correlation with values measured by the Clauss method, and the diagnostic accuracy for hypofibrinogenemia was high, but there were many residuals above 100 mg/dL, and the distribution of these residuals was not uniform. Although thromboelastography cannot be used to directly measure fibrinogen values, maximum amplitude citrated functional fibrinogen, amplitude-10 citrated rapid thromboelastography, and amplitude-10 citrated functional fibrinogen showed a strong positive correlation with fibrinogen values using the Clauss method, and no significant difference in correlation or diagnostic accuracy was observed relative to dry hematology. CONCLUSION: Dry hematology and thromboelastography were equally accurate in diagnosing hypofibrinogenemia, with results correlating well with fibrinogen values measured by the Clauss method.

来源:Am J Obstet Gynecol MFM,查看原文。版权归原作者所有。

引用

  1. Nakamura E, Matsunaga S, Kikuchi A, et al. Comparative retrospective study on the validity of point-of-care testing device for massive obstetrical hemorrhage: dry hematology vs thromboelastography. Am J Obstet Gynecol MFM. 2022. PMID: 36273811. doi:10.1016/j.ajogmf.2022.100778

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。