双触发与标准HCG触发对胚胎形态动力学参数影响的比较
本研究比较双触发(曲普瑞林0.2 mg联合重组人绒毛膜促性腺激素250 µg)与标准重组HCG触发对胚胎质量及形态动力学参数的影响。共分析4859枚胚胎(双触发组1803枚来自267个周期,HCG组3056枚来自463个周期)。结果显示两组形态动力学参数及胚胎质量无显著差异。
要点
- 双触发组与HCG组在受精卵至8细胞期的卵裂时间无差异。
- HCG组具有最佳cc2持续时间的胚胎比例更高。
- 多因素分析中触发类型不是细胞周期分裂参数的显著影响因素。
核心结论
- 总体而言,双触发与HCG触发所获胚胎在形态动力学参数及使用延时监测系统评估的胚胎质量方面无显著差异。
研究设计与样本
- 研究纳入≤42岁女性首个GnRH拮抗剂IVF/ICSI周期,比较双触发(曲普瑞林0.2 mg联合重组HCG 250 µg)与标准重组HCG 250 µg触发所获胚胎的形态动力学参数和胚胎质量。
- 共分析4859枚胚胎:双触发组1803枚来自267个周期,HCG组3056枚来自463个周期。
- 采用多因素线性回归和逻辑回归分析校正混杂因素。
主要发现
- 双触发组母亲体重指数更高且成熟率更低,其余患者和治疗特征两组相似。
- 双触发组第二极体排出时间更短。
- 受精卵至8细胞期的卵裂时间两组无差异。
- HCG组具有最佳cc2持续时间的胚胎比例更高。
- 多因素逻辑回归模型中,触发类型不是细胞周期分裂参数的显著影响因素。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
RESEARCH QUESTION: Does dual trigger (the co-administration of triptorelin 0.2 mg and recombinant human chorionic gonadotrophin (HCG) [Decapeptyl 0.2 mg + Ovitrelle 250 µg]) versus standard recombinant HCG (Ovitrelle 250 µg) affect embryo quality and morphokinetic parameters? DESIGN: Morphokinetic parameters and embryo quality of embryos derived from the first gonadotrophin-releasing hormone (GnRH) antagonist IVF/intracytoplasmic sperm injection (ICSI) cycles triggered by dual trigger or standard HCG trigger in women ≤42 years. Outcome measures included time to pronucleus fading (tPNf), cleavage timings (t2-t8), synchrony of the second cycle (s2), duration of the second cycle (cc2) and known implantation data (KID) scoring for embryo quality. Multivariate linear and logistic regression analyses were performed for confounding factors. RESULTS: A total of 4859 embryos were analysed: 1803 embryos from 267 cycles in the dual trigger group and 3056 embryos from 463 cycles in the HCG trigger group. The groups were similar in patient and treatment characteristics apart from a higher maternal body mass index and lower maturation rate in the dual trigger group. Time to second polar body extrusion was shorter in the dual trigger group. Cleavage timings from zygote to an 8-cell embryo did not differ between the two groups. There was a higher percentage of embryos with an optimal cc2 duration in the HCG group. In multivariate logistic regression models, the trigger type was not a significant factor for cell cycle division parameters. CONCLUSIONS: Overall, there was no significant difference in the morphokinetic parameters or quality of embryos evaluated using a time-lapse monitoring system between embryos derived following dual trigger compared with HCG.
引用
- Oron G, Sapir O, Shufaro Y, et al. Effect of the co-administration of HCG and GnRH agonist (dual trigger) versus standard HCG trigger on morphokinetic embryo parameters. Reprod Biomed Online. 2022. PMID: 35963755. doi:10.1016/j.rbmo.2022.05.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。