文献速递生殖医学

基于低深度下一代测序的染色体结构重排植入前遗传学检测能准确区分易位患者的正常胚胎与携带者胚胎

Preimplantation genetic testing for structural rearrangement based on low-coverage next-generation sequencing accurately discriminates between normal and carrier embryos for patients with translocations.
PubMed 文献 · Reprod Biomed Online · 2022-05-21

本研究纳入109对相互易位或罗伯逊易位夫妇,采用0.1×全基因组测序识别非平衡/平衡胚胎,2×全基因组测序结合单倍型分析区分正常与携带者胚胎。103枚平衡胚胎中鉴定出53枚正常胚胎,移植32枚,持续妊娠率46.88%(15/32),羊膜腔穿刺核型结果与PGT-SR诊断100%一致。

要点

  • 低深度NGS的PGT-SR可区分平衡胚胎的正常与携带者状态。
  • 32枚正常胚胎移植后持续妊娠率为46.88%(15/32)。
  • 所有持续妊娠的羊膜腔穿刺核型与PGT-SR诊断100%一致。

核心结论

  • 基于低深度NGS的PGT-SR方法能准确区分平衡胚胎的正常与携带者状态,且成本效益好、具有广泛临床适用性。

研究设计与样本

  • 研究纳入109对相互易位或罗伯逊易位夫妇,记录年龄、不良产科病史、血核型和IVF周期信息。
  • 对胚胎行0.1×全基因组测序识别非平衡/平衡,对父母和胚胎行2×全基因组测序结合单倍型分析区分正常与携带者。
  • 移植无易位胚胎并评估临床结局。

主要发现

  • 109对夫妇中67例为相互易位,42例为罗伯逊易位。
  • 非平衡和平衡检测后,103枚平衡胚胎进一步行正常与携带者区分,鉴定出53枚正常胚胎。
  • 移植32枚正常胚胎,持续妊娠率为46.88%(15/32)。
  • 所有持续妊娠行羊膜腔穿刺,核型结果与PGT-SR诊断100%一致。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

RESEARCH QUESTION: Can preimplantation genetic testing for structural rearrangement (PGT-SR) based on low-coverage next-generation sequencing (NGS) accurately discriminate between normal and carrier embryos of reciprocal translocation (RecT) and Robertsonian translocation (RobT)? DESIGN: A total of 109 couples with RecT or RobT were included in this study. The ages, bad obsteric histories (BOH), blood karyotype and IVF cycle information, including the number of cumulus-oocyte complexes, metaphase II oocytes, two pronuclei oocytes and blastocysts were recorded. 0.1 × whole genome sequencing (WGS) of embryos followed by copy number variation (identifying unbalanced/balanced) and 2 × WGS of parents and embryos followed by haplotype analysis (discriminating between normal and carrier) were carried out in PGT-SR cycles. The embryos without translocation were transferred and clinical outcomes evaluated. RESULTS: Among all the couples in this study, 67 patients had RecT and 42 had RobT. After unbalanced and balanced detection, 103 balanced embryos underwent a further normal and carrier discrimination procedure, and 53 normal embryos were identified. Finally, 32 normal embryos were transferred, with an ongoing pregnancy rate of 46.88% (15/32). All ongoing pregnancies underwent amniocentesis, and the amninocentesis karyotyping results showed 100% concordance with PGT-SR diagnosis. CONCLUSIONS: Our low-coverage NGS-based PGT-SR method can accurately discriminate between normal and carrier status of balanced embryos. The method is cost-effective and has broad clinical applicability.

来源:Reprod Biomed Online,查看原文。版权归原作者所有。

引用

  1. Zhai F, Wang Y, Li H, et al. Preimplantation genetic testing for structural rearrangement based on low-coverage next-generation sequencing accurately discriminates between normal and carrier embryos for patients with translocations. Reprod Biomed Online. 2022. PMID: 35780041. doi:10.1016/j.rbmo.2022.05.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。