孕中期早产筛查中全扩张剖宫产瘢痕评估的可重复性

Reproducibility of assessment of full-dilatation Cesarean section scar in women undergoing second-trimester screening for preterm birth.
PubMed 文献 · Ultrasound Obstet Gynecol · 2022-01-01

前瞻性单中心可重复性研究纳入72例有全扩张剖宫产史的单胎孕妇,于14-24周经阴道超声评估剖宫产瘢痕、瘢痕龛及其与宫颈内口的位置关系。瘢痕显示率>80%,实时二维图像观察者间一致性优秀(κ=0.84和0.85),瘢痕至宫颈内口距离是最可重复的二维测量,龛测量可重复性最差。

要点

  • 实时二维与离线二维静图的整体可重复性高于三维容积图像。
  • 瘢痕至宫颈内口距离最可重复:观察者内95%LOA在±1.6 mm内,观察者间在±2.7 mm内。
  • 龛测量可重复性最差:观察者内95%LOA为±1.6至±3.6 mm,观察者间为±3.1至±6.3 mm。

核心结论

  • 有全扩张剖宫产史的孕妇在后续妊娠孕中期可用二维或三维容积超声评估剖宫产瘢痕位置和瘢痕龛,可重复性高。
  • 整体上最可重复的剖宫产瘢痕参数是瘢痕至宫颈内口的距离。
  • 作者认为本研究提出的方法应能使临床医生可靠地评估剖宫产瘢痕,并可能有助于预测妊娠结局。

研究设计与样本

  • 前瞻性单中心可重复性研究,纳入单胎妊娠且有全扩张剖宫产史、于14-24周接受经阴道超声评估宫颈长度和剖宫产瘢痕特征的孕妇。
  • 为达到所需统计效能,共招募72例孕妇。
  • 剖宫产瘢痕定义为子宫下段前壁或宫颈肌层低回声线性不连续;瘢痕龛定义为瘢痕处深度至少2 mm的凹陷。
  • 在矢状面和横切面评估瘢痕龛参数,包括长度、深度、宽度及残余和邻近肌层厚度。
  • 定性可重复性通过瘢痕和龛可见性的一致性评估;定量可重复性使用实时二维图像、离线二维静图和三维容积图像三套图像评估。

主要发现

  • 剖宫产瘢痕在>80%的图像中可见;实时二维图像中瘢痕显示和龛存在的观察者间一致性优秀,κ系数分别为0.84和0.85。
  • 所有图像集的观察者内可重复性95%LOA在±1.1至±3.6 mm之间;观察者间可重复性95%LOA在±2.0至±6.3 mm之间。
  • 瘢痕至宫颈内口距离是最可重复的二维测量:观察者内95%LOA在±1.6 mm内,观察者间95%LOA在±2.7 mm内。
  • 龛测量整体上是最不可重复的测量:观察者内95%LOA为±1.6至±3.6 mm,观察者间95%LOA为±3.1至±6.3 mm。
  • 重新采集二维图像后测量、在存储二维图像上放置卡尺或容积操作所得测量之间无一致差异。

关键数值与推荐

  • 瘢痕显示和龛存在的观察者间κ系数分别为0.84和0.85(实时二维图像)。
  • 观察者内95%LOA为±1.1至±3.6 mm,观察者间95%LOA为±2.0至±6.3 mm(所有图像集)。
  • 瘢痕至宫颈内口距离的观察者内95%LOA在±1.6 mm内,观察者间95%LOA在±2.7 mm内。
  • 龛测量的观察者内95%LOA为±1.6至±3.6 mm,观察者间95%LOA为±3.1至±6.3 mm。

临床怎么用

  • 作者认为本研究提出的方法应能使临床医生可靠地评估剖宫产瘢痕,并可能有助于预测妊娠结局。
  • 原文未据此给出其他推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess the reproducibility of a standardized method of measuring the Cesarean section (CS) scar, CS scar niche and their position relative to the internal os of the uterine cervix by transvaginal ultrasound in pregnant women with a previous full-dilatation CS. METHODS: This was a prospective, single-center reproducibility study on women with a singleton pregnancy and a previous full-dilatation CS who underwent transvaginal ultrasound assessment of cervical length and CS scar characteristics at 14-24 weeks' gestation. The CS scar was identified as a hypoechogenic linear discontinuity of the myometrium at the anterior wall of the lower uterine segment or cervix. The CS scar niche was identified as an indentation at the site of the scar with a depth of at least 2 mm. The CS scar position was evaluated by measuring the distance to the internal cervical os. CS scar niche parameters, including its length, depth, width, and residual and adjacent myometrial thickness, were assessed in the sagittal and transverse planes. Qualitative reproducibility was assessed by agreement regarding visibility of the CS scar and niche. Quantitative reproducibility of CS scar measurements was assessed using three sets of images: (1) real-time two-dimensional (2D) images (real-time acquisition and caliper placement on 2D images by two operators), (2) offline 2D still images (offline caliper placement by two operators on stored 2D images acquired by one operator) and (3) three-dimensional (3D) volume images (volume manipulation and caliper placement on 2D images extracted by two operators). Agreement on CS scar visibility and the presence of a niche was analyzed using kappa coefficients. Intraobserver and interobserver reproducibility of quantitative measurements was assessed using Bland-Altman plots. RESULTS: To achieve the desired statistical power, 72 women were recruited. The CS scar was visualized in > 80% of images. Interobserver agreement for scar visualization and presence of a niche in real-time 2D images was excellent (kappa coefficients of 0.84 and 0.85, respectively). Overall, reproducibility was higher for real-time 2D and offline 2D still images than for 3D volume images. The 95% limits of agreement (LOA) for intraobserver reproducibility were between ± 1.1 and ± 3.6 mm for all sets of images; the 95% LOA for interobserver reproducibility were between ± 2.0 and ± 6.3 mm. Measurement of the distance from the CS scar to the internal cervical os was the most reproducible 2D measurement (intraobserver and interobserver 95% LOA within ± 1.6 and ± 2.7 mm, respectively). Overall, niche measurements were the least reproducible measurements (intraobserver 95% LOA between ± 1.6 and ± 3.6 mm; interobserver 95% LOA between ± 3.1 and ± 6.3 mm). There was no consistent difference between measurements obtained by reacquisition of 2D images (planes obtained twice and caliper placed), caliper placement on 2D stored images or volume manipulation (planes obtained twice and caliper placed). CONCLUSIONS: The CS scar position and scar niche in pregnant women with a previous full-dilatation CS can be assessed in the second trimester of a subsequent pregnancy using either 2D or 3D volume ultrasound imaging with a high level of reproducibility. Overall, the most reproducible CS scar parameter is the distance from the CS scar to the internal cervical os. The method proposed in this study should enable clinicians to assess the CS scar reliably and may help predict pregnancy outcome. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.