文献速递妇科

子宫内膜癌患者接受一步法和两步法前哨淋巴结定位时术前PET-CT的实用性与潜在陷阱:PET-CT阴性结果真的代表淋巴结阴性吗

Usefulness and potential pitfalls of pre-operative PET-CT in patients with endometrial cancer undergoing one- and two-step sentinel lymph node mapping: Do negative findings on PET-CT negativity really indicate node negativity?
PubMed 文献 · Gynecol Oncol · 2022-07-28

在2014年7月至2021年4月期间,466例子宫内膜癌患者接受FDG PET-CT后行腹腔镜或机器人手术分期及前哨淋巴结定位,分为PET阳性组和PET阴性组。PET-CT诊断淋巴结转移的敏感度为46.2%、特异度为96.7%;PET阴性患者中4例(2.3%)有腹主动脉旁前哨淋巴结转移,且仅见于两步法组。作者认为PET-CT解剖一致性高但敏感度有限,两步法前哨淋巴结技术可能对PET阴性和阳性患者均有用。

要点

  • PET-CT诊断淋巴结转移敏感度46.2%、特异度96.7%,特异度高但敏感度有限。
  • PET阴性患者中4例(2.3%)有腹主动脉旁前哨淋巴结转移,仅见于两步法组。
  • PET阳性淋巴结转移患者中解剖分布一致者为14/18(77.8%)。

核心结论

  • PET-CT可为临床医生提供有用的指导,在淋巴结转移患者中解剖一致率高,但尽管特异度高,敏感度有限。
  • 前哨淋巴结转移模式尤其是腹主动脉旁水平提示,两步法前哨淋巴结技术可能对PET阴性和PET阳性患者均有用。

研究设计与样本

  • 在延世癌症中心2014年7月至2021年4月期间,对接受FDG PET-CT后行腹腔镜或机器人手术分期及前哨淋巴结定位的子宫内膜癌患者进行回顾性图表审查。
  • 患者分为PET阳性组(疑似或可能淋巴结转移)和PET阴性组,一步法为传统宫颈注射法(n=276),两步法为宫底注射后宫颈注射(n=190),共466例。

主要发现

  • 434例PET阴性患者中21例检出淋巴结转移,32例PET阳性患者中18例检出淋巴结转移。
  • PET-CT诊断淋巴结转移的敏感度为46.2%,特异度为96.7%。
  • PET阳性且淋巴结转移患者中,解剖分布一致者为14/18(77.8%)。
  • PET阴性患者中4例(2.3%)有转移性腹主动脉旁前哨淋巴结,包括3例(1.7%)孤立性腹主动脉旁转移,且仅见于两步法组。
  • PET阳性患者中,腹主动脉旁前哨淋巴结转移在两步法组为35.7%、一步法组为16.7%;21例PET假阴性患者中,中位随访34个月(范围7-70个月)后4例(19%)复发。

关键数值与推荐

  • PET-CT诊断淋巴结转移的敏感度为46.2%,特异度为96.7%。
  • PET阳性且淋巴结转移患者中解剖分布一致率为77.8%(14/18)。
  • PET阴性患者中转移性腹主动脉旁前哨淋巴结发生率为2.3%(4例),孤立性腹主动脉旁转移为1.7%(3例)。
  • PET阳性患者中腹主动脉旁前哨淋巴结转移率:两步法组35.7%,一步法组16.7%。
  • PET假阴性患者中位随访34个月(范围7-70个月)后复发率为19%(4例)。

临床怎么用

  • 作者认为PET-CT可作为临床医生的有用指导,在淋巴结转移患者中解剖一致率高,但敏感度有限。
  • 作者认为前哨淋巴结转移模式尤其是腹主动脉旁水平提示,两步法前哨淋巴结技术可能对PET阴性和PET阳性患者均有用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: We investigated the utility of Positron emission tomography-Computed tomography (PET-CT) in the setting of two different sentinel lymph node (SLN) mapping techniques; the conventional cervical injection method (one-step) and the two-step method, which involves fundal injection followed by cervical injection. METHODS: Patients with endometrial cancer undergoing FDG PET-CT followed by laparoscopic or robotic surgical staging with SLN mapping at the Yonsei Cancer Center between July 2014 and April 2021 were stratified into the PET-positive group (with suspected or likely lymph nodes metastasis) and PET-negative group. A chart review was performed for the number of harvested SLNs, patterns of SLN metastases, and recurrence. RESULTS: Among 466 patients undergoing one-step (n = 276) and two-step (n = 190) SLN mapping, LN metastasis was identified in 21 of 434 PET-negative and 18 of 32 PET-positive patients. The sensitivity and specificity of PET-CT for diagnosing lymph node metastasis were 46.2% and 96.7%, respectively. Among PET-positive patients with LN metastasis, anatomical distribution was concordant in 14/18 patients (77.8%). Among PET-negative patients, four (2.3%) had metastatic para-aortic SLNs, including three (1.7%) with isolated para-aortic metastases; metastatic para-aortic SLNs were exclusively found in the two-step group. Among PET-positive patients, para-aortic SLN metastasis was identified in 35.7% of two-step and 16.7% of one-step group. Among the 21 PET false-negative patients, recurrence was seen in four patients (19%) after a median follow-up of 34 months (range: 7-70 months). CONCLUSIONS: PET-CT served as a useful guide to clinicians with high anatomical concordance rate in patients with LN metastasis. However, despite high specificity, sensitivity was limited. SLN metastasis pattern, especially at the para-aortic level, indicates that the two-step SLN technique might be useful in PET-negative and PET-positive patients.

来源:Gynecol Oncol,查看原文。版权归原作者所有。

引用

  1. Kim YN, Lee D, Cha J, et al. Usefulness and potential pitfalls of pre-operative PET-CT in patients with endometrial cancer undergoing one- and two-step sentinel lymph node mapping: Do negative findings on PET-CT negativity really indicate node negativity? Gynecol Oncol. 2022. PMID: 35907682. doi:10.1016/j.ygyno.2022.07.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。