指南与共识产科母胎医学

定义至关重要:采用SMFM生物测量标准与ISUOG/Delphi共识标准产前诊断的晚发型胎儿生长受限婴儿的检出率与围产结局

Definitions matter: detection rates and perinatal outcome for infants classified prenatally as having late fetal growth restriction using SMFM biometric vs ISUOG/Delphi consensus criteria.
指南 / 共识 · Ultrasound Obstet Gynecol · 2023-01-01

该回顾性队列研究在澳大利亚布里斯班Mater Mother's Hospital纳入2014年1月至2020年12月足月分娩的非畸形单胎,比较SMFM生物测量标准与ISUOG/Delphi共识标准筛查晚发型胎儿生长受限的效能。两种标准对出生体重低于第10百分位或第3百分位婴儿的筛查潜力强,但对新生儿不良结局的预测效能较低。

要点

  • SMFM与ISUOG/Delphi标准对出生体重低于第10百分位或第3百分位婴儿的筛查潜力强。
  • ISUOG/Delphi标准预测出生体重低于第10百分位小于胎龄儿的比值比低于SMFM标准。
  • 两种标准对复合严重新生儿疾病或非 reassuring 胎状态急诊剖宫产的预测效能较低,阳性似然比均小于10。

核心结论

  • SMFM与ISUOG/Delphi标准对出生体重低于第10百分位或第3百分位婴儿的筛查潜力强,但对新生儿不良结局的筛查效能较低。

研究设计与样本

  • 回顾性队列研究,纳入2014年1月至2020年12月在澳大利亚布里斯班Mater Mother's Hospital转诊并足月分娩的非畸形单胎婴儿。
  • 按SMFM标准(估计胎儿体重或腹围低于第10百分位)与ISUOG/Delphi共识标准(晚发型胎儿生长受限,诊断孕周≥32周)进行分类。
  • 计算各超声变量的敏感度、特异度、阳性预测值、阴性预测值、假阳性率、假阴性率、阳性似然比和阴性似然比以评估筛查效能。

主要发现

  • SMFM与ISUOG/Delphi标准共分类1030例为晚发型胎儿生长受限,其中400例同时符合两种标准,548例仅符合SMFM标准,82例仅符合ISUOG/Delphi标准。
  • 产前检出晚发型胎儿生长受限与出生体重低于第10百分位的比值比:SMFM标准aOR 133.0(95%CI 94.7-186.6),ISUOG/Delphi标准aOR 69.5(95%CI 49.1-98.2)。
  • 产前检出晚发型胎儿生长受限与出生体重低于第3百分位的比值比:SMFM标准aOR 348.7(95%CI 242.6-501.2),ISUOG/Delphi标准aOR 215.4(95%CI 148.4-312.7)。
  • 与SMFM标准相比,ISUOG/Delphi标准预测出生体重低于第10百分位小于胎龄儿的比值比更低(aOR 0.5,95%CI 0.3-0.8),但预测非 reassuring 胎状态急诊剖宫产的比值比更高(aOR 2.30,95%CI 1.14-4.66),预测复合新生儿疾病的比值比更高(aOR 1.22,95%CI 1.05-1.41)。
  • SMFM与ISUOG/Delphi标准对出生体重低于第10百分位和第3百分位婴儿的预测均具有高阳性似然比、特异度、阳性预测值和阴性预测值,但对复合严重新生儿疾病或非 reassuring 胎状态急诊剖宫产的预测阳性似然比均小于10。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Fetal growth restriction (FGR) is often secondary to placental dysfunction and is suspected prenatally based on biometric or circulatory abnormalities detected on ultrasound. The aims of this study were to compare the screening performance of the Society for Maternal-Fetal Medicine (SMFM) biometric criteria (estimated fetal weight (EFW) or abdominal circumference (AC) < 10th centile) with that of the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG)-endorsed Delphi consensus criteria for late FGR for delivery of a small-for-gestational-age (SGA) infant at term, emergency Cesarean section (CS) for non-reassuring fetal status (NRFS), perinatal mortality and composite severe neonatal morbidity. METHODS: We classified retrospectively non-anomalous singleton infants as having late FGR (diagnosed ≥ 32 weeks) according to SMFM and ISUOG/Delphi criteria in a cohort of women who had been referred to the Mater Mother's Hospital, Brisbane, Australia and who delivered at term between January 2014 and December 2020. The study outcomes were delivery of a SGA infant (birth weight (BW) < 10th or < 3rd centile), emergency CS for NRFS, perinatal mortality (defined as stillbirth or neonatal death within 28 days of a live birth) and a composite of severe neonatal morbidity. We assessed the screening performance of various ultrasound variables by calculating the sensitivity, specificity, positive (PPV) and negative (NPV) predictive values, false-positive and false-negative rates, positive likelihood ratio (LR+) and negative likelihood ratio. RESULTS: The SMFM and ISUOG/Delphi consensus criteria collectively classified 1030 cases as having late FGR. Of these, 400 cases were classified by both SMFM and ISUOG/Delphi criteria, whilst 548 cases were classified using only SMFM criteria and 82 cases were classified only by ISUOG/Delphi criteria. Prenatal detection of late FGR by SMFM and ISUOG/Delphi criteria was associated with increased odds of delivery of an infant with BW < 10th centile (SMFM: adjusted odds ratio (aOR), 133.0 (95% CI, 94.7-186.6); ISUOG/Delphi: aOR, 69.5 (95% CI, 49.1-98.2)) or BW < 3rd centile (SMFM: aOR, 348.7 (95% CI, 242.6-501.2); ISUOG/Delphi: aOR, 215.4 (95% CI, 148.4-312.7)). Compared with the SMFM criteria, the ISUOG/Delphi criteria were associated with lower odds (aOR, 0.5 (95% CI, 0.3-0.8)) of predicting a SGA infant with BW < 10th centile, but higher odds of predicting emergency CS for NRFS (aOR, 2.30 (95% CI, 1.14-4.66)) and composite neonatal morbidity (aOR, 1.22 (95% CI, 1.05-1.41)). Both SMFM and ISUOG/Delphi criteria were associated with high LR+, specificity, PPV and NPV for the prediction of infants with BW < 10th and BW < 3rd centile. However, both methods functioned much less efficiently for the prediction of composite severe neonatal morbidity or emergency CS for NRFS, with LR+ < 10. The SMFM biometric criteria alone, particularly AC < 3rd centile, had the highest LR+ values for the prediction of perinatal mortality. CONCLUSION: Both the SMFM and ISUOG/Delphi criteria had strong screening potential for the detection of infants with BW < 10th or < 3rd centile but not for adverse neonatal outcome. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Schreiber V, Hurst C, da Silva Costa F, et al. Definitions matter: detection rates and perinatal outcome for infants classified prenatally as having late fetal growth restriction using SMFM biometric vs ISUOG/Delphi consensus criteria. Ultrasound Obstet Gynecol. 2023. PMID: 35866888. doi:10.1002/uog.26035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。