文献速递生殖医学

精子DNA碎片(经末端脱氧核苷酸转移酶生物素dUTP缺口末端标记法检测)不损害以每使用一枚供卵MII卵母细胞累计活产率衡量的生殖成功

Sperm deoxyribonucleic acid fragmentation (by terminal deoxynucleotidyl transferase biotin dUTP nick end labeling assay) does not impair reproductive success measured as cumulative live birth rates per donor metaphase II oocyte used.
PubMed 文献 · Fertil Steril · 2022-05-23

该多中心回顾性队列研究纳入2000至2019年864对使用供卵行ICSI的夫妇,用TUNEL法检测精子DNA碎片。比较SDF≤15%与>15%或按10%区间分组,首次移植及所有移植的活产率无显著差异,每移植、每移植胚胎及每消耗供卵MII卵母细胞的累计活产率Kaplan-Meier曲线相似。

要点

  • SDF≤15%与>15%或按10%区间分组,首次及所有移植的活产率均无显著差异。
  • 每移植、每移植胚胎及每消耗供卵MII卵母细胞的累计活产率曲线在SDF组间相似。
  • 高SDF不降低ICSI周期中按上述单位计算的活产率或累计获得孩子的概率。

核心结论

  • 高SDF不降低行ICSI周期夫妇按每移植、每移植胚胎及每使用供卵MII卵母细胞计算的活产率或累计获得孩子的概率。

研究设计与样本

  • 多中心回顾性队列研究,纳入2000至2019年864对使用供卵行ICSI的夫妇,共1903个ICSI周期、6340枚供卵、2543枚胚胎和1145次胚胎移植。
  • 精子DNA碎片用末端脱氧核苷酸转移酶生物素dUTP缺口末端标记法检测,采用Kaplan-Meier生存曲线计算累计活产率。

主要发现

  • SDF≤15%(低)与>15%(高)或按10%SDF区间比较,首次移植及所有移植的活产率均无显著差异。
  • 每移植、每移植胚胎及每消耗供卵MII卵母细胞的累计活产率Kaplan-Meier曲线在评估的SDF组间相似。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To better study the effect of sperm deoxyribonucleic acid fragmentation (SDF) on intracytoplasmic sperm injection (ICSI) outcomes from an ovum donation program by assessing the cumulative live birth rates (CLBRs) per number of embryo transfers (ETs), embryos replaced (EmbR), and metaphase II (MII) oocytes required in consecutive treatments to achieve the first newborn. DESIGN: A multicenter retrospective cohort study was conducted, and the Kaplan-Meier survival curves were generated to calculate the CLBR with regard to the SDF degree. SETTING: Private university-affiliated in vitro fertilization centers. PATIENT(S): Data from 864 couples using donated eggs and undergoing ICSI from 2000 to 2019 were analyzed. Sperm deoxyribonucleic acid fragmentation was measured using terminal deoxynucleotidyl transferase biotin dUTP nick end labeling assay on their ejaculated sperm. INTERVENTION(S): None. MAIN OUTCOME MEASURE(S): Live birth rate (LBR) per first ET and per all consecutive ETs within the same patient and CLBR per ET, per EmbR, and per MII oocyte used considering the SDF level. RESULT(S): A total of 1,903 ICSI cycles were considered, encompassing 6,340 donated oocytes, 2,543 embryos, and 1,145 ETs. Comparing ≤15% SDF (low) with >15% SDF (high) or by 10% SDF ranges, the LBRs per first ET and per all ETs did not significantly differ. The Kaplan-Meier curves of the CLBR per ET, per EmbR, and per donor oocyte consumed were similar between the SDF groups evaluated. CONCLUSION(S): Elevated SDF does not reduce the LBR or cumulative probability to obtain a child when calculated per ET, per EmbR, and per donated MII oocyte used in couples undergoing ICSI cycles.

来源:Fertil Steril,查看原文。版权归原作者所有。

引用

  1. Hervás I, Pacheco A, Gil Julia M, et al. Sperm deoxyribonucleic acid fragmentation (by terminal deoxynucleotidyl transferase biotin dUTP nick end labeling assay) does not impair reproductive success measured as cumulative live birth rates per donor metaphase II oocyte used. Fertil Steril. 2022. PMID: 35618526. doi:10.1016/j.fertnstert.2022.04.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。