剖宫产子宫切口缝合中无结倒刺缝线对比传统缝线的系统评价与Meta分析
该系统评价与Meta分析比较剖宫产子宫切口缝合使用无结倒刺缝线(KBS)与传统光滑缝线的围手术期结局,纳入4项研究共3332名产妇(KBS组1473例,传统缝线组1859例)。KBS组子宫切口缝合时间显著更短(均数差-110.58秒,95%CI -127.37至-93.79,p=.001),额外止血缝合使用率显著更低(OR 0.14,95%CI 0.07-0.26,p=.001),术后肠梗阻发生率显著更低(OR 0.31,95%CI 0.11-0.89,p=.029),总手术时间、输血率、发热病率及术后住院时间两组相当。
要点
- KBS组子宫切口缝合时间较传统缝线组显著缩短(均数差-110.58秒,95%CI -127.37至-93.79,p=.001)。
- KBS组额外止血缝合使用率显著低于传统缝线组(OR 0.14,95%CI 0.07-0.26,p=.001)。
- KBS组术后肠梗阻发生率显著低于传统缝线组(OR 0.31,95%CI 0.11-0.89,p=.029)。
核心结论
- 剖宫产子宫切口缝合使用KBS与缝合时间缩短及额外止血缝合需求减少相关,其他围手术期结局未受影响,但术后肠梗阻风险降低。
研究设计与样本
- 系统评价与Meta分析,检索MEDLINE、EMBASE、Web of Sciences、Scopus、Cochrane Library和ClinicalTrials.gov从建库至2021年3月,无语言限制。
- 纳入回顾性和随机对照的同行评议研究,比较剖宫产子宫切口缝合使用KBS与传统缝线,最终纳入4项研究共3332名产妇(KBS组1473例,传统缝线组1859例)。
- 采用Cochrane偏倚风险工具评估研究质量,所有研究均判定为低偏倚风险。
- 主要结局为子宫切口缝合时间(秒),次要结局包括总手术时间(分钟)、额外止血缝合使用、输血率及术后并发症。
主要发现
- KBS组子宫切口缝合时间显著低于传统缝线组(均数差-110.58秒,95%CI -127.37至-93.79,p=.001)。
- KBS组额外止血缝合使用率显著低于传统缝线组(OR 0.14,95%CI 0.07-0.26,p=.001)。
- KBS组术后肠梗阻发生率显著低于传统缝线组(OR 0.31,95%CI 0.11-0.89,p=.029)。
- 总手术时间、输血率、发热病率及术后住院时间两组相当。
关键数值与推荐
- KBS组子宫切口缝合时间均数差-110.58秒(95%CI -127.37至-93.79,p=.001)。
- KBS组额外止血缝合使用OR 0.14(95%CI 0.07-0.26,p=.001)。
- KBS组术后肠梗阻OR 0.31(95%CI 0.11-0.89,p=.029)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To compare perioperative outcomes between knotless barbed sutures (KBSs) and conventional smooth sutures for uterine incision closure at cesarean section. DATA SOURCES: MEDLINE, EMBASE, Web of Sciences, Scopus, the Cochrane Library, and ClinicalTrials.gov were searched from the inception of the study to March 2021 without language restriction. The search terms were as follows: ["Stratafix" OR "Quill" OR "V-Loc" OR "Barbs" OR "barbed"] AND ["Cesarean" OR "Caesarean"] AND ["Suturing" OR "Suture" OR "Closure" OR "Repair"]. Moreover, these terms were combined to complete the search. METHODS OF STUDY SELECTION: Retrospective and randomized peer-reviewed studies comparing the use of KBSs and conventional sutures for uterine incision closure at cesarean section were included. The studies' quality was assessed by the Cochrane risk-of-bias tool. The primary outcome was the time of uterine incision closure in seconds. The secondary outcomes included total operating time (minutes), use of additional hemostatic sutures, rates of blood transfusion, and postoperative complications. TABULATION, INTEGRATION, AND RESULTS: Of 20 reports identified, 4 representing 3332 women (1473 with KBSs and 1859 with conventional sutures) were eligible. All studies were judged to be at low risk of bias. The uterine incision closure time was significantly lower in the KBS group (mean difference, -110.58; 95% confidence interval [CI], -127.37 to -93.79; p = .001). Furthermore, the rate of use of additional hemostatic sutures was significantly lower in the KBS group (odds ratio, 0.14; 95% CI, 0.07-0.26; p = .001). Total operative time, rates of blood transfusion, febrile morbidity, and length of postoperative stay were comparable. The incidence of postoperative ileus was significantly lower in the KBS group (odds ratio, 0.31; 95% CI, 0.11-0.89; p = .029). CONCLUSION: The use of KBSs for uterine incision closure was associated with decreased hysterotomy closure time and less frequent need for the placement of additional hemostatic sutures. Other perioperative outcomes were not affected, although the risk of postoperative ileus was reduced.
引用
- Raischer HB, Massalha M, Iskander R, et al. Knotless Barbed versus Conventional Suture for Closure of the Uterine Incision at Cesarean Delivery: A Systematic Review and Meta-analysis. J Minim Invasive Gynecol. 2022. PMID: 35533955. doi:10.1016/j.jmig.2022.05.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。