经阴道超声采用国际深部子宫内膜异位症分析(IDEA)方法诊断子宫内膜异位症的诊断准确性:前瞻性国际先导研究
该国际多中心前瞻性诊断准确性研究纳入273例疑似子宫内膜异位症患者,术前按IDEA共识行经阴道超声,以腹腔镜直视和病理为参考标准。深部子宫内膜异位症总体诊断准确性86.1%(腹腔镜参考)和85.9%(病理参考),敏感性88.4%和89.8%,特异性78.8%和75.9%。
要点
- IDEA共识方法对深部子宫内膜异位症的经阴道超声诊断具有较高准确性。
- 以腹腔镜为参考,敏感性88.4%、特异性78.8%、准确性86.1%。
- 以病理为参考,敏感性89.8%、特异性75.9%、准确性85.9%。
核心结论
- 采用IDEA共识方法,经阴道超声评估深部子宫内膜异位症具有较高诊断准确性。
- 本研究报告的深部子宫内膜异位症总体检出率高于近期一项Meta分析(敏感性79%),但特异性较低。
研究设计与样本
- 国际多中心前瞻性诊断准确性研究,涉及六个国家的八个中心,时间为2018年8月至2019年11月。
- 连续纳入基于临床症状或既往子宫内膜异位症诊断而怀疑子宫内膜异位症的参与者。
- 索引试验为术前按IDEA共识声明的经阴道超声,每个中心由一名超声医师判读。
- 参考标准为腹腔镜下子宫内膜异位症直视(由非盲的子宫内膜异位症手术专家判定)和活检/切除组织的组织学评估。
- 手术在索引经阴道超声后12个月内进行;273例参与者具有完整临床、经阴道超声、腹腔镜和组织学数据。
主要发现
- 基于组织学,256/273(93.8%)确诊子宫内膜异位症(包括浅表子宫内膜异位症),190/273(69.6%)确诊深部子宫内膜异位症。
- 基于手术直视,207/273(75.8%)患者有深部子宫内膜异位症。
- 以手术直视为标准,经阴道超声诊断深部子宫内膜异位症的准确性86.1%、敏感性88.4%、特异性78.8%、阳性预测值92.9%、阴性预测值68.4%、阳性似然比4.17、阴性似然比0.15。
- 以组织学为标准,经阴道超声诊断深部子宫内膜异位症的准确性85.9%、敏感性89.8%、特异性75.9%、阳性预测值90.4%、阴性预测值74.6%、阳性似然比3.72、阴性似然比0.13。
关键数值与推荐
- 深部子宫内膜异位症总体(手术直视参考):准确性86.1%、敏感性88.4%、特异性78.8%、阳性预测值92.9%、阴性预测值68.4%、阳性似然比4.17、阴性似然比0.15。
- 深部子宫内膜异位症总体(组织学参考):准确性85.9%、敏感性89.8%、特异性75.9%、阳性预测值90.4%、阴性预测值74.6%、阳性似然比3.72、阴性似然比0.13。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the diagnostic accuracy of transvaginal ultrasound (TVS) in predicting deep endometriosis (DE) following the International Deep Endometriosis Analysis (IDEA) consensus methodology. METHODS: This was an international multicenter prospective diagnostic accuracy study involving eight centers across six countries (August 2018-November 2019). Consecutive participants with endometriosis suspected based on clinical symptoms or historical diagnosis of endometriosis were included. The index test was TVS performed preoperatively in accordance with the IDEA consensus statement. At each center, the index test was interpreted by a single sonologist. Reference standards were: (1) direct visualization of endometriosis at laparoscopy, as determined by a non-blinded surgeon with expertise in endometriosis surgery; and (2) histological assessment of biopsied/excised tissue. Surgery was performed within 12 months following the index TVS. Accuracy, sensitivity, specificity, positive and negative predictive values (PPV and NPV) and positive and negative likelihood ratios (LR+ and LR-) of TVS in the diagnosis of DE were calculated. RESULTS: Included in the study were 273 participants with complete clinical, TVS, laparoscopic and histological data. Of these, based on histology, 256 (93.8%) were confirmed to have endometriosis, including superficial endometriosis, and 190 (69.6%) were confirmed to have DE. Based on surgical visualization, 207/273 (75.8%) patients had DE. For DE overall, the diagnostic performance of TVS based on surgical visualization as the reference standard was as follows: accuracy, 86.1%; sensitivity, 88.4%; specificity, 78.8%; PPV, 92.9%; NPV, 68.4%; LR+, 4.17; LR-, 0.15, and the diagnostic performance of TVS based on histology as the reference standard was as follows: accuracy, 85.9%; sensitivity, 89.8%; specificity, 75.9%; PPV, 90.4%; NPV, 74.6%; LR+, 3.72; LR-, 0.13. CONCLUSIONS: Using the IDEA consensus methodology provides strong diagnostic accuracy for TVS assessment of DE. We found a higher TVS detection rate of DE overall than that reported by the most recent meta-analysis on the topic (sensitivity, 79%), albeit with a lower specificity. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Leonardi M, Uzuner C, Mestdagh W, et al. Diagnostic accuracy of transvaginal ultrasound for detection of endometriosis using International Deep Endometriosis Analysis (IDEA) approach: prospective international pilot study. Ultrasound Obstet Gynecol. 2022. PMID: 35561121. doi:10.1002/uog.24936
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。