文献速递产科母胎医学

妊娠早期通过宫颈长度和剪切波弹性成像筛查自发性早产

Screening for spontaneous preterm birth by cervical length and shear-wave elastography in the first trimester of pregnancy.
PubMed 文献 · Am J Obstet Gynecol · 2022-04-20

该前瞻性研究纳入2316例未选择的单胎妊娠孕妇,在11+0至13+6周比较两种宫颈长度测量方法及宫颈剪切波弹性成像对自发性早产的预测价值。双线法宫颈长度预测<34周自发性分娩的曲线下面积优于单线法(0.658 vs 0.573,P<.01),弹性成像平均评分MOM<第10百分位者<34周自发性分娩的相对风险为7.8。

要点

  • 双线法宫颈长度预测<34周自发性分娩的AUC为0.658,优于单线法的0.573(P<.01)。
  • 双线法宫颈长度联合早产史预测<34周自发性分娩的AUC为0.692。
  • 弹性成像平均评分MOM<第10百分位者<34周自发性分娩的RR为7.8(95%CI 2.1-28.6)。

核心结论

  • 双线法能更好地估计妊娠早期实际宫颈长度,作为<34周自发性分娩的筛查工具性能优于传统测量方法。
  • 妊娠早期剪切波弹性成像确定的软宫颈与随后自发性早产风险增加相关。

研究设计与样本

  • 前瞻性研究,纳入2316例11+0至13+6周未选择的单胎妊娠孕妇。
  • 基础队列中分别用单线法和双线法测量宫颈长度,亚研究经阴道超声获取中矢面9个感兴趣区的剪切波弹性成像评分。
  • 采用受试者工作特征曲线分析评估筛查性能,DeLong检验比较曲线下面积。

主要发现

  • <37周和<34周自发性分娩分别发生111例(4.8%)和20例(0.9%)。
  • 与足月分娩组相比,<34周自发性分娩组双线法宫颈长度中位数更短(36.9 mm vs 35.1 mm;P=.015),单线法宫颈长度未见明确相关性。
  • 双线法预测<34周自发性分娩的AUC为0.658,单线法为0.573(P<.01)。
  • 双线法宫颈长度联合早产史预测<34周自发性分娩的AUC为0.692。
  • 弹性成像平均评分MOM<第10百分位者<34周自发性分娩的RR为7.8(95%CI 2.1-28.6),假阳性率9.0%时检出率为44.4%。

关键数值与推荐

  • 双线法宫颈长度预测<34周自发性分娩的AUC为0.658,单线法为0.573(P<.01)。
  • 双线法宫颈长度联合早产史预测<34周自发性分娩的AUC为0.692。
  • 弹性成像平均评分MOM<第10百分位者<34周自发性分娩的RR为7.8(95%CI 2.1-28.6)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: First-trimester cervical length for the prediction of spontaneous preterm delivery remains controversial. A better method for the measurement of the first-trimester cervical length and additional cervical ultrasound parameters for the identification of women at high risk for spontaneous preterm delivery are needed. OBJECTIVE: This study aimed to compare the predictive value of cervical length measured by 2 different methods in the first trimester of pregnancy to predict spontaneous preterm delivery and to explore the potential value of first-trimester cervical shear-wave elastography for the prediction of spontaneous preterm delivery. STUDY DESIGN: This was a prospective study in unselected singleton pregnancies at 11+0 to 13+6 weeks' gestation. Cervical length was measured by the following 2 methods in the base-cohort population: (1) a linear distance between the 2 ends of the glandular area around the endocervical canal (single-line method: cervical length-s) and (2) a sum of the linear distance from the internal os to the greatest cervical curvature and the linear distance from this point to the external os (2-line method: cervical length-t). In a substudy, cervical shear-wave elastography scores for 9 regions of interest (inner, middle, and external parts of anterior lip, endocervical canal, and posterior lip) in midsagittal plane were also obtained by transvaginal ultrasonography. The screening performance of the first-trimester cervical length measured by the 2 different methods for the prediction of spontaneous preterm delivery was assessed by receiver operating characteristics curve analysis. The areas under the curves were compared using a DeLong test. The predictive performance of a soft cervix (mean elastography scores with multiple of median <5th, 10th, 15th, 20th, and 25th percentile) for spontaneous preterm delivery was also determined. RESULTS: Among a total of 2316 included pregnancies, spontaneous delivery at <37 and <34 weeks' gestation occurred in 111 cases (4.8%) and 20 cases (0.9%), respectively. In the total study population, when compared with the term delivery group, the median cervical length-t was shorter in women with spontaneous delivery at <34 weeks' gestation (36.9 mm vs 35.1 mm; P=.015), but there was no clear correlation for cervical length-s. Receiver operating characteristics curves demonstrated that cervical length-t achieved better performance in predicting spontaneous delivery at <34 weeks' gestation (area under the curve, 0.658 vs 0.573; P<.01) than cervical length-s. The best combined model to predict spontaneous delivery at <34 weeks' gestation was provided by cervical length-t and history of preterm delivery (area under the curve, 0.692). In the substudy, a soft cervix with a mean elastography scores multiple of median <10th percentile had a relative risk of 7.8 (95% confidence interval, 2.1-28.6) for spontaneous delivery at <34 weeks' gestation; the detection rate was 44.4% at a false-positive rate of 9.0%. CONCLUSION: The 2-line approach provides a better estimate of the actual first-trimester cervical length and achieves better performance as a screening tool for spontaneous preterm delivery at <34 weeks' gestation than the conventional measurement. A soft cervix as determined by shear-wave elastograpthy in the first trimester is associated with an increased risk for subsequent spontaneous preterm delivery.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Feng Q, Chaemsaithong P, Duan H, et al. Screening for spontaneous preterm birth by cervical length and shear-wave elastography in the first trimester of pregnancy. Am J Obstet Gynecol. 2022. PMID: 35460624. doi:10.1016/j.ajog.2022.04.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。