超声提示宫颈短时行数字宫颈检查的作用
该回顾性队列研究纳入256例孕中期超声提示宫颈短(经阴道宫颈长度≤25 mm)且在超声后1周内行数字宫颈检查的单胎妊娠女性,发现40.2%存在宫颈扩张,且扩张率随宫颈长度缩短而升高;仅凭临床和超声特征预测宫颈扩张的模型效能中等(AUC 0.77)。
要点
- 超声提示宫颈短(≤25 mm)者中40.2%数字检查发现宫颈扩张。
- 宫颈扩张率随超声宫颈长度缩短而升高,0.0-4.9 mm组达69%。
- 作者认为超声宫颈短(尤其<20 mm)时应考虑行数字宫颈检查以发现宫颈扩张。
核心结论
- 作者认为超声提示宫颈短(尤其<20 mm)时应考虑行数字宫颈检查以发现宫颈扩张。
研究设计与样本
- 回顾性队列研究,在学术机构开展,纳入256例单胎妊娠、超声检测宫颈短(经阴道宫颈长度≤25 mm)且在超声后1周内有数字宫颈检查记录的女性。
主要发现
- 256例超声提示宫颈短女性中103例(40.2%)数字宫颈检查发现宫颈扩张。
- 宫颈扩张率随超声宫颈长度缩短而升高:宫颈长度20.0-25.0 mm组为15%,15.0-19.9 mm组为39%,10.0-14.9 mm组为53%,5.0-9.9 mm组为64%,0.0-4.9 mm组为69%。
- 母亲种族或族裔(作为社会建构考察)、保险状态、未产、既往宫颈切除手术史、超声漏斗化及超声宫颈长度均与宫颈扩张相关。
- 将上述所有变量纳入回归模型,预测宫颈扩张的效能仅为中等,受试者工作特征曲线下面积为0.77(95%置信区间,0.71-0.83)。
关键数值与推荐
- 超声宫颈长度≤25 mm定义为宫颈短。
- 数字宫颈检查需在超声后1周内完成。
临床怎么用
- 作者认为超声提示宫颈短(尤其<20 mm)时应考虑行数字宫颈检查以发现宫颈扩张。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Universal transvaginal cervical length screening has been associated with a reduction in the frequency of preterm birth. However, there is no clinically set standard to guide the performance of a digital cervical examination in the setting of a sonographically short cervix. OBJECTIVE: To investigate the prevalence of cervical dilation at various midtrimester transvaginal cervical length thresholds. Furthermore, we sought to identify sonographic or clinical characteristics associated with cervical dilation that may inform who would benefit from a digital cervical examination in the setting of a sonographically short cervix. STUDY DESIGN: This retrospective cohort study was conducted at an academic institution and included women with a singleton gestation and an ultrasonographically detected short cervix (defined as a transvaginally obtained cervical length ≤25 mm) who had a documented digital cervical examination within 1 week of the ultrasonography. Bivariable analyses were used to determine the relationship between cervical length and the presence of cervical dilation. Multivariable logistic regression and receiver operating characteristic curve were used to evaluate the relationship between clinical and sonographic risk factors and cervical dilation. RESULTS: Of the 256 women who met eligibility criteria and had a sonographically detected short cervix, 103 (40.2%) were found to be dilated on digital cervical examination. The prevalence of cervical dilation increased as sonographic cervical length decreased; cervical dilation was identified in 15%, 39%, 53%, 64%, and 69% of women with a cervical length between 20.0 and 25.0 mm, 15.0 and 19.9 mm, 10.0 and 14.9 mm, 5.0 and 9.9 mm, and 0.0 and 4.9 mm, respectively. Maternal race or ethnicity (examined as a social construct), insurance status, nulliparity, previous cervical excisional procedure, funneling on ultrasonography, and sonographic cervical length were each associated with cervical dilation. However, including all of these variables into a regression yielded a model with only moderate predictive ability to identify cervical dilation, with receiver operating area under the curve of 0.77 (95% confidence interval, 0.71-0.83). CONCLUSION: Consideration should be given to performing a digital cervical examination in the setting of a sonographically short cervix (especially <20 mm) to detect cervical dilation.
引用
- Shahawy S, Henricks AA, Chow KY, et al. The role of digital examination in the setting of a sonographically short cervix. Am J Obstet Gynecol MFM. 2022. PMID: 35462059. doi:10.1016/j.ajogmf.2022.100650
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。