文献速递产科母胎医学

胎儿生长受限中配对脐动脉多普勒测速的不一致性与临床意义

Doppler velocimetry discordance between paired umbilical artery vessels and clinical implications in fetal growth restriction.
PubMed 文献 · Am J Obstet Gynecol · 2022-03-17

该队列纳入425例25至39周生长受限胎儿,测量脐带中段两条脐动脉的搏动指数。配对脐动脉搏动指数平均差异为11.7%,15.8%的病例差异超过20%;双正常占71.1%,双异常占12.2%,不一致占16.7%(P<.0001)。取两条脐动脉中较高搏动指数时异常检出率最高(28.9%),高于随机取一条(22.1%)和取平均值(19.2%)(P=.003)。

要点

  • 生长受限胎儿中配对脐动脉搏动指数平均差异11.7%,15.8%病例差异超过20%。
  • 双正常、双异常、不一致分别占71.1%、12.2%、16.7%(P<.0001)。
  • 取较高搏动指数时异常检出率28.9%,高于随机取一条22.1%和取平均19.2%。

核心结论

  • 在该大型胎儿生长受限队列中,两条脐动脉搏动指数的总体差异为11.7%。
  • 在至少一条脐动脉搏动指数异常的胎儿中,71/123(57.7%)为一条正常、一条异常。
  • 采样的动脉数量和采样方法可能改变临床决策,包括监测频率和分娩时机。

研究设计与样本

  • 队列研究,纳入425例25至39周生长受限胎儿,测量脐带中段两条脐动脉的多普勒搏动指数。
  • 比较三种采样方法:两条脐动脉搏动指数平均值、随机选取一条脐动脉的搏动指数、两条脐动脉中较高的搏动指数。

主要发现

  • 配对脐动脉搏动指数平均差异为11.7%,15.8%的病例差异超过20%。
  • 两条脐动脉搏动指数均正常者占71.1%(302/425),均异常者占12.2%(52/425),不一致者占16.7%(71/425)(P<.0001)。
  • 搏动指数异常检出率:取两条平均值时为19.2%(82/425),随机取一条时为22.1%(94/425),取较高值时28.9%(123/425)(P=.003)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Studies revealing a discrepancy in umbilical artery Dopplers between the two umbilical arteries in normally-grown fetuses necessitates further evaluation of the paired umbilical arteries in the setting of fetal growth restriction as this is a critical component in the surveillance of this population. OBJECTIVE: Umbilical artery Doppler sampling in fetal growth restriction is typically assessed in 1 umbilical artery in a free loop of cord. Although discrepancies of >20% between the 2 umbilical arteries occur in 1 of 3 normal pregnancies, this has not been assessed in fetal growth restriction. Our objectives were to determine the frequency of discordant Doppler pulsatility indices between paired umbilical arteries in a fetal growth restriction cohort and to determine if sampling of 1 or both arteries alters surveillance or timing of delivery. STUDY DESIGN: A cohort of 425 growth-restricted fetuses between 25 and 39 weeks of gestation had umbilical artery Doppler pulsatility indices determined from both umbilical arteries in a midsegment of the cord to determine: (1) the discrepancy percentage between paired umbilical artery pulsatility indices and (2) the frequency of both arteries being normal, abnormal, or discordant (pulsatility index < and >95th percentile). To determine what sampling method increased the detection of an abnormal Doppler index, 3 sampling methods were compared: (1) average pulsatility index from both umbilical arteries, (2) pulsatility index from 1 umbilical artery chosen randomly, and (3) highest pulsatility index of the 2 umbilical arteries. RESULTS: The mean percentage difference between umbilical artery pulsatility indices was 11.7%, and in 15.8% of cases, it exceeded 20%. Both umbilical artery pulsatility indices were normal in 71.1% (302/425), abnormal in 12.2% (52/425), and discordant in 16.7% (71/425) of cases (P<.0001). Of the 3 sampling methods, the pulsatility index was abnormal in: (1) 19.2% (82/425) of cases when averaged from both umbilical arteries, (2) 22.1% (94/425) of cases when choosing 1 umbilical artery at random, and (3) 28.9% (123/425) of cases when the highest umbilical artery pulsatility index was used (P=.003). CONCLUSION: In this large fetal growth restriction cohort, the overall discrepancy between the 2 umbilical artery pulsatility indices was 11.7%. Among fetuses with at least 1 abnormal umbilical artery pulsatility index, 71 of 123 (57.7%) had 1 normal pulsatility index and 1 abnormal. Thus, the number of arteries sampled and the sampling method used may alter clinical decision-making, including frequency of surveillance and timing of delivery.

来源:Am J Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Steller JG, Driver C, Gumina D, et al. Doppler velocimetry discordance between paired umbilical artery vessels and clinical implications in fetal growth restriction. Am J Obstet Gynecol. 2022. PMID: 35307395. doi:10.1016/j.ajog.2022.03.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。