孕中期短宫颈患者的子宫肌电图研究
这项前瞻性队列研究纳入28例单胎无畸形妊娠16周0天至22周6天的孕妇,比较宫颈长度正常(≥3.0 cm)与短宫颈(<2.5 cm)者的子宫肌电图信号。短宫颈组短爆发和爆发信号百分比显著高于正常宫颈组,且宫颈长度与短爆发和爆发信号百分比呈负相关。
要点
- 短宫颈孕妇孕中期子宫肌电图中短爆发和爆发信号百分比显著高于正常宫颈孕妇。
- 宫颈长度与短爆发信号百分比(P=.013)和爆发信号百分比(P=.014)呈负相关。
- 短宫颈且有早产史者爆发信号百分比高于短宫颈无早产史者(12.8% vs 3.3%,P=.003)。
核心结论
- 孕中期短宫颈患者中短爆发和爆发子宫肌电图信号更常见,为宫颈缩短的异常肌层激活提供了生物生理学联系。
研究设计与样本
- 前瞻性队列研究,纳入单胎无畸形妊娠16周0天至22周6天的孕妇,宫颈长度正常(≥3.0 cm)者与短宫颈(<2.5 cm)者比较,短宫颈组按早产史进一步分层,共28例受试者。
主要发现
- 正常宫颈组尖峰信号百分比为96.3%(四分位距93.1%-100.0%),短宫颈组为75.2%(四分位距66.7%-92.0%),P=.001。
- 短宫颈组短爆发信号百分比为17.3%(四分位距13.6%-23.9%),正常宫颈组为2.5%(四分位距0%-5.5%),P=.001。
- 短宫颈组爆发信号百分比为6.6%(四分位距0%-13.4%),正常宫颈组为0%(四分位距0%-2.8%),P=.014。
- 宫颈长度与短爆发信号百分比呈负相关(P=.013),与爆发信号百分比呈负相关(P=.014)。
- 短宫颈且有早产史者爆发信号百分比为12.8%(四分位距9.0%-15.7%),短宫颈无早产史者为3.3%(四分位距0%-5.0%),P=.003。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Preterm birth is the largest single cause of infant death in the United States. A cervical length of <2.5 cm, measured in the mid-trimester, has been shown to identify individuals at increased risk. Uterine electromyography is an emerging technology for noninvasively assessing uterine bioelectrical activity. With its ability to characterize nuanced differences in myometrial signals, uterine electromyography assessments during the mid-trimester may provide insight into the mechanisms of cervical shortening. OBJECTIVE: This study aimed to characterize uterine bioelectrical activity in pregnant individuals with short cervices in the mid-trimester compared with that of pregnant individuals of the same gestational age with normal cervical lengths. STUDY DESIGN: This is a prospective cohort study of subjects with singleton, nonanomalous pregnancies between 16 weeks and 0 days and 22 weeks and 6 days of gestational age. Subjects with normal cervical length (≥3.0 cm) were compared with subjects with short cervical length (<2.5 cm). The short-cervical-length cohort was further stratified by history of preterm birth. Multichannel uterine electromyography recordings were obtained for ∼60 minutes using proprietary, directional electromyography sensors on the abdomen. Uterine electromyography signals were observed and classified in groups as spikes, short bursts, and bursts. Primary outcomes were relative expression of spike, short-burst, and burst uterine electromyography signals. Subgroup analyses assessed each signal percentage by cervical length, history of preterm birth, and gestational age at delivery. Differences in percentage of uterine electromyography signals according to cervical length were analyzed using nonparametric tests of significance. RESULTS: Of the 28 included subjects, 10 had normal and 18 had short cervical length. There were 9 subjects with short cervical length and a history of preterm birth. Spikes were the most commonly recorded signals and were higher in the normal-cervical-length cohort (96.3% [interquartile range, 93.1%-100.0%]) than the short-cervical-length cohort (75.2% [interquartile range, 66.7%-92.0%], P=.001). In contrast, median percentages of short-bursts and bursts were significantly higher in subjects with a short cervical length (17.3% [interquartile range, 13.6%-23.9%] vs 2.5% for normal cervical length [interquartile range, 0%-5.5%], P=.001 and 6.6% [interquartile range, 0%-13.4%] vs 0% for normal cervical length [interquartile range, 0%-2.8%], P=.014, respectively). Within subgroup analyses, cervical length was inversely proportional to percentage of observed short-bursts (P=.013) and bursts (P=.014). Subjects with short cervical length and history of preterm birth had higher burst percentages (12.8% [interquartile range, 9.0%-15.7%]) than those with short cervical length and no history of preterm birth (3.3% [interquartile range, 0%-5.0%], P=.003). CONCLUSION: Short-burst and burst uterine electromyography signals are observed more frequently in mid-trimester patients with short cervical lengths. This relationship provides insight into abnormal myometrial activation in the mid-trimester and offers a plausible biophysiological link to cervical shortening.
引用
- Marinescu PS, Young RC, Miller LA, et al. Mid-trimester uterine electromyography in patients with a short cervix. Am J Obstet Gynecol. 2022. PMID: 35351409. doi:10.1016/j.ajog.2022.03.046
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。