文献速递产科母胎医学

美国宫内标准与出生体重标准定义的新生儿小于胎龄儿对短期新生儿疾病与死亡的预测效能

Predictive performance of newborn small for gestational age by a United States intrauterine vs birthweight-derived standard for short-term neonatal morbidity and mortality.
PubMed 文献 · Am J Obstet Gynecol MFM · 2022-02-18

该研究为多中心观察性研究的二次分析,纳入78,203例23至41周单胎无畸形活产儿,比较宫内标准(Hadlock)与出生体重标准(Olsen)定义的小于胎龄儿对复合新生儿疾病与死亡结局的预测效能。两种标准总体预测能力均弱,足月时均无判别能力,宫内标准曲线下面积高于出生体重标准。

要点

  • 宫内标准诊断小于胎龄儿占14.8%,出生体重标准占7.4%(P<.001)。
  • 仅宫内标准判为小于胎龄儿者主要结局发生率18.4%,两标准均非小于胎龄儿者为7.9%(P<.001)。
  • 预测主要结局,宫内标准敏感性29%高于出生体重标准15%,特异性87%低于93%(P均<.001)。

核心结论

  • 在无畸形新生儿中,宫内标准与出生体重标准定义的小于胎龄儿均不能准确预测新生儿疾病与死亡,足月时均无判别能力。
  • 宫内标准定义的小于胎龄儿预测效能优于出生体重标准。

研究设计与样本

  • 多中心观察性研究的二次分析,纳入23至41周单胎无畸形活产儿78,203例(占母胎对115,502例的67.7%)。
  • 采用宫内标准(Hadlock)与出生体重标准(Olsen)计算出生体重百分位,小于胎龄儿定义为出生体重低于第10百分位。
  • 主要结局为复合新生儿疾病与死亡(出院前死亡、新生儿重症监护病房入住>48小时、呼吸窘迫综合征、败血症、坏死性小肠结肠炎、3或4级脑室内出血或惊厥),严重复合结局为次要结局。

主要发现

  • 主要复合结局发生率为9.5%(95%CI 9.3-9.7),严重复合结局发生率为5.3%(95%CI 5.1-5.4)。
  • 宫内标准诊断小于胎龄儿占14.8%,出生体重标准占7.4%(P<.001)。
  • 仅宫内标准判为小于胎龄儿者主要结局发生率18.4%,两标准均非小于胎龄儿者为7.9%(P<.001)。
  • 预测主要结局,宫内标准敏感性29% vs 出生体重标准15%(P<.001),特异性87% vs 93%(P<.001),曲线下面积0.58 vs 0.53(P<.001)。
  • 预测严重结局,宫内标准曲线下面积0.65 vs 出生体重标准0.57(P<.001);足月分娩时两标准曲线下面积均为0.50。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The use of birthweight standards to define small for gestational age may fail to identify neonates affected by poor fetal growth as they include births associated with suboptimal fetal growth. OBJECTIVE: This study aimed to compare intrauterine vs birthweight-derived standards to define newborn small for gestational age to predict neonatal morbidity and mortality. STUDY DESIGN: This was a secondary analysis of a multicenter observational study of 118,422 births. Live-born singleton, nonanomalous newborns born at 23 to 41 weeks of gestation were included. Those with missing gestational age estimation or without a first- or second-trimester ultrasound to confirm dating, birthweight, or neonatal outcome data were excluded. Birthweight percentile was computed using an intrauterine standard (Hadlock) and a birthweight-derived standard (Olsen). We compared the test characteristics of small for gestational age (birthweight of <10th percentile) by each standard to predict a composite neonatal morbidity and mortality outcome (death before discharge, neonatal intensive care unit admission >48 hours, respiratory distress syndrome, sepsis, necrotizing enterocolitis, grade 3 or 4 intraventricular hemorrhage, or seizures). Severe composite morbidity was analyzed as a secondary outcome and was defined as death, neonatal intensive care unit admission >7 days, necrotizing enterocolitis, grade 3 or 4 intraventricular hemorrhage, or seizures. The areas under the curve using receiver-operating characteristic methodology and proportions of the primary outcome by small for gestational age status were compared by gestational age category at birth (<34, 34 0/7 to 36 6/7, ≥37 weeks). RESULTS: Of 115,502 mother-newborn dyads in the parent study, 78,203 (67.7%) were included, with most exclusions occurring because of missing or inadequate dating information, multiple gestations, or delivery outside the gestational age range. The primary composite outcome occurred in 9.5% (95% confidence interval, 9.3-9.7), and the severe composite outcome occurred in 5.3% (95% confidence interval, 5.1-5.4). Small for gestational age was diagnosed by intrauterine and birthweight-derived standards in 14.8% and 7.4%, respectively (P<.001). Neonates considered small for gestational age only by the intrauterine standard experienced the primary outcome more than twice as often as those considered non-small for gestational age by both standards (18.4% vs 7.9%; P<.001). For the prediction of the primary outcome, small for gestational age by the intrauterine standard had higher sensitivity (29% vs 15%; P<.001) but lower specificity (87% vs 93%; P<.001) than by the birthweight standard. Both standards had weak performance overall, although the intrauterine standard had a higher area under the curve (0.58 vs 0.53; P<.001). When subanalyzed by gestational age at birth, the difference in areas under the curve was only present among preterm deliveries 34 to 36 competed weeks. Neither standard demonstrated any discrimination for morbidity prediction among term births (area under the curve, 0.50 for both). When the prediction of severe morbidity was compared, the intrauterine still had better overall prediction than the birthweight standard (areas under the curve, 0.65 vs 0.57; P<.001), although this also varied by gestational age at birth. CONCLUSION: Among nonanomalous neonates, neither intrauterine nor birthweight-derived standards for small for gestational age accurately predicted neonatal morbidity and mortality, with no discriminatory ability at term. Small for gestational age intrauterine standards performed better than birthweight standards.

来源:Am J Obstet Gynecol MFM,查看原文。版权归原作者所有。

引用

  1. Blue NR, Mele L, Grobman WA, et al. Predictive performance of newborn small for gestational age by a United States intrauterine vs birthweight-derived standard for short-term neonatal morbidity and mortality. Am J Obstet Gynecol MFM. 2022. PMID: 35183799. doi:10.1016/j.ajogmf.2022.100599

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。