文献速递母胎医学产科

共同动脉干的产前诊断准确性及其影响

Accuracy and impact of prenatal diagnosis of common arterial trunk.
PubMed 文献 · Ultrasound Obstet Gynecol · 2022-06-30

本研究回顾性分析2011至2019年单中心84例共同动脉干(CAT)患者,评估产前诊断解剖亚型与干瓣功能的准确性,并比较产前与产后诊断患者的死亡率和发病率。产前诊断解剖亚型准确率80.3%,干瓣功能评估一致性差;产前诊断组干预更早、插管时间和住院时间更短,但死亡率无显著差异。

要点

  • 产前诊断CAT解剖亚型准确率80.3%,与产后诊断一致性仅中等(κ=0.43)。
  • 胎儿评估干瓣功能不可靠,关闭不全存在和严重程度均一致性差。
  • 产前诊断组干预更早、插管时间和住院时间更短,死亡率无显著差异。

核心结论

  • 产前诊断CAT的准确性不足以指导新生儿管理和预测结局。
  • 胎儿评估干瓣功能障碍因围产期过渡而显得不可靠。
  • 需要改进对需产后前列腺素输注的CAT解剖亚型的胎儿诊断。

研究设计与样本

  • 回顾性分析2011至2019年单中心所有产前诊断(经产后或尸检确认)或产后诊断的CAT患者。
  • 共纳入84例患者:62例产前诊断活产儿、16例产后诊断活产儿和6例终止妊娠后尸检。
  • 使用Cohen kappa统计量评估产前与产后解剖亚型(Van Praagh分型)和干瓣功能评估的一致性。
  • 比较产前诊断与产后诊断CAT患者的死亡率和发病率变量。

主要发现

  • 产前诊断CAT解剖亚型的准确率为80.3%,产前与产后亚型诊断一致性仅中等(κ=0.43)。
  • CAT Type A3患者产前均未诊断(0/4),CAT Type A4患者仅半数产前诊断(8/17)。
  • 胎儿评估干瓣关闭不全的存在(无一致性;κ=0.09)和严重程度(轻微一致性;κ=0.19)均低估。
  • 产后确认的显著干瓣狭窄5例中4例产前诊断,存在和严重程度一致性均为一般(κ分别为0.38和0.24)。
  • 产前诊断与未产前诊断患者死亡率相当(log-rank P=0.87)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Outcome of common arterial trunk (CAT) depends mainly on truncal valve function, presence of coronary artery abnormalities and presence of interrupted aortic arch. The main objective of this study was to evaluate the accuracy of prenatal diagnosis of CAT by analyzing prenatal vs postnatal assessment of: (1) anatomic subtypes and (2) truncal valve function. The secondary objective was to assess the potential impact of prenatal diagnosis of CAT on postnatal mortality and morbidity by comparing prenatally vs postnatally diagnosed patients. METHODS: This was a retrospective analysis of all CAT patients diagnosed either prenatally, with postnatal or fetopsy confirmation, or postnatally, from 2011 to 2019 in a single tertiary center. Cohen's kappa statistic was used to evaluate agreement between pre- and postnatal assessment of anatomic subtypes according to Van Praagh and of truncal valve function. Mortality and morbidity variables were compared between prenatally vs postnatally diagnosed CAT patients. RESULTS: A total of 84 patients (62 liveborn with prenatal diagnosis, 16 liveborn with postnatal diagnosis and six terminations of pregnancy with fetopsy) met the inclusion criteria. The accuracy of prenatal diagnosis of CAT anatomic subtype was 80.3%, and prenatal and postnatal concordance for subtype diagnosis was only moderate (κ = 0.43), with no patient with CAT Type A3 (0/4) and only half of patients with CAT Type A4 (8/17) being diagnosed prenatally. Fetal evaluation of truncal valve function underestimated the presence (no agreement; κ = 0.09) and severity (slight agreement; κ = 0.19) of insufficiency. However, four of five cases of postnatally confirmed significant truncal valve stenosis were diagnosed prenatally, with fair agreement for both presence and severity of stenosis (κ = 0.38 and 0.24, respectively). Mortality was comparable in patients with and those without prenatal diagnosis (log-rank P = 0.87). CAT patients with fetal diagnosis underwent earlier intervention (P < 0.001), had shorter intubation time (P = 0.047) and shorter global hospital stay (P = 0.01). CONCLUSIONS: The accuracy of prenatal diagnosis of CAT is insufficient to tailor neonatal management and to predict outcome. Fetal assessment of truncal valve dysfunction appears unreliable due to perinatal transition. Improvement is necessary in the fetal diagnosis of anatomic subtypes of CAT requiring postnatal prostaglandin infusion. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Laux D, Derridj N, Stirnemann J, et al. Accuracy and impact of prenatal diagnosis of common arterial trunk. Ultrasound Obstet Gynecol. 2022. PMID: 35118719. doi:10.1002/uog.24873

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。