文献速递产科

剖宫产术中子宫缝合使用单股线与多股线的比较:一项随机临床试验

Monofilament vs multifilament suture for uterine closure at the time of cesarean delivery: a randomized clinical trial.
PubMed 文献 · Am J Obstet Gynecol MFM · 2022-02-04

在意大利单中心纳入300例足月单胎剖宫产孕妇,按1:1随机分为单股线组(聚甘醇酸6211)与多股线组(涂层聚乳酸910含三氯生),比较术后6个月超声剖宫产瘢痕缺损发生率。单股线组18.4%(25/136)vs 多股线组23.4%(32/137),相对风险0.79(95%CI 0.41-1.25;P=.31),残余肌层厚度平均差异+0.40 mm(95%CI -0.23至1.03),作者结论为单股线未显著降低瘢痕缺损率。

要点

  • 单股线组与多股线组6个月剖宫产瘢痕缺损率分别为18.4%与23.4%,差异未达统计学显著(RR 0.79,95%CI 0.41-1.25;P=.31)。
  • 残余肌层厚度单股线组7.6 mm vs 多股线组7.2 mm,平均差异+0.40 mm(95%CI -0.23至1.03)。
  • 盆腔痛、痛经、性交痛等症状发生率两组间无实质差异。

核心结论

  • 在初次或第二次剖宫产的单胎妊娠中,子宫壁缝合使用合成可吸收单股线与多股线相比,术后6个月剖宫产瘢痕缺损发生率未见降低。

研究设计与样本

  • 平行组、非盲法随机临床试验,在意大利单中心纳入足月单胎剖宫产孕妇。
  • 纳入标准为单胎妊娠、初次或第二次剖宫产、计划或急诊/紧急剖宫产、孕周37 0/7至42 0/7周。
  • 共300例随机分组,单股线组151例、多股线组149例;失访27例(单股线组15例、多股线组12例)。
  • 单股线组使用聚甘醇酸6211(Caprosyn;Covidien,都柏林,爱尔兰),多股线组使用涂层聚乳酸910含三氯生缝线(Vicryl Plus;Ethicon,拉里坦,新泽西州)。

主要发现

  • 术后6个月剖宫产瘢痕缺损发生率单股线组为18.4%(25/136)vs 多股线组23.4%(32/137),相对风险0.79(95%CI 0.41-1.25;P=.31)。
  • 残余肌层厚度均值单股线组7.6 mm vs 多股线组7.2 mm,平均差异+0.40 mm(95%CI -0.23至1.03)。
  • 盆腔痛、痛经、性交痛等症状发生率两组间无实质差异。

临床怎么用

  • 作者结论认为,单股线缝合子宫与多股线相比未降低术后6个月剖宫产瘢痕缺损率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Different factors may influence the closure of the uterine wall, including suture material. Suture materials may indeed influence tissue healing and therefore the development of scar defects. OBJECTIVE: To test whether uterine closure using synthetic absorbable monofilament sutures at the time of cesarean delivery would reduce the rate of cesarean scar defects compared with uterine closure using synthetic absorbable multifilament sutures. STUDY DESIGN: Parallel-group, nonblinded, randomized clinical trial of women with singleton pregnancies undergoing cesarean delivery at term in a single center in Italy. The inclusion criteria were singleton pregnancy, first or second cesarean delivery, scheduled and emergent or urgent cesarean deliveries, and gestational age between 37 0/7 and 42 0/7 weeks. Eligible participants were randomly allocated in a 1:1 ratio to either the monofilament group (polyglytone 6211 [Caprosyn]; Covidien, Dublin, Ireland) or the multifilament suture group (coated polyglactin 910 suture with Triclosan [Vicryl Plus]; Ethicon, Inc, Raritan, NJ). The primary outcome was the incidence of cesarean scar defect at ultrasound at the 6-month follow-up visit. The secondary outcomes were residual myometrial thickness and symptoms. RESULTS: Overall, 300 women were included in the trial. Of the randomized women, 151 were randomized to the monofilament group and 149 to the multifilament group. However, 27 women were lost to follow-up: 15 in the monofilament group and 12 in the multifilament group. Of note, 6 months after delivery, the incidence rates of cesarean scar defect were 18.4% (25 of 136 patients) in the monofilament group and 23.4% (32 of 137 patients) in the multifilament group (relative risk, 0.79; 95% confidence interval, 0.41-1.25; P=.31). The mean residual myometrial thicknesses were 7.6 mm in the monofilament group and 7.2 mm in the multifilament group (mean difference, +0.40 mm; 95% confidence interval, -0.23 to 1.03). There was no between-group substantial difference found in the incidence of symptoms, including pelvic pain, painful periods, and dyspareunia. CONCLUSION: In singleton pregnancies undergoing primary or second cesarean delivery, the use of synthetic absorbable monofilament sutures at the time of uterine wall closure was not associated with a reduction in the rate of cesarean scar defect 6 months after delivery compared with the use of synthetic absorbable multifilament sutures.

来源:Am J Obstet Gynecol MFM,查看原文。版权归原作者所有。

引用

  1. Saccone G, De Angelis MC, Zizolfi B, et al. Monofilament vs multifilament suture for uterine closure at the time of cesarean delivery: a randomized clinical trial. Am J Obstet Gynecol MFM. 2022. PMID: 35131497. doi:10.1016/j.ajogmf.2022.100592

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。