体内拉曼光谱监测分娩过程中的宫颈变化
研究纳入30名自然临产或引产的孕妇,用光纤探针拉曼光谱在分娩期间每4小时采集体内光谱直至胎膜破裂,线性混合效应模型显示胶原及细胞外基质蛋白相关峰强度显著下降(P=.0054)、血液相关特征升高(P=.0372)、脂质相关特征升高(P=.0273),非负最小二乘模型显示胶原贡献随时间下降、血液贡献升高、脂质贡献变化。作者认为体内拉曼光谱可灵敏反映分娩宫颈生化重塑变化,可能成为客观评估宫颈的工具。
要点
- 分娩期间宫颈胶原及细胞外基质蛋白相关拉曼特征显著下降(P=.0054)。
- 血液相关拉曼特征随分娩进展显著升高(P=.0372)。
- 脂质相关拉曼特征随分娩进展显著升高(P=.0273)。
核心结论
- 体内拉曼光谱可灵敏检测分娩期间宫颈多种生化重塑变化。
- 体内拉曼光谱可能成为客观评估宫颈、潜在指导分娩临床管理的无创工具。
研究设计与样本
- 共招募30名自然临产或引产的孕妇。
- 使用带光纤探针的拉曼系统在分娩期间每4小时体内采集光谱直至胎膜破裂。
- 采用线性混合效应模型分析峰强度或峰比值随时间至分娩的显著变化(P<.05)。
- 采用非负最小二乘生化模型提取特定分子类别贡献随时间的变化。
主要发现
- 胶原及其他细胞外基质蛋白相关拉曼光谱特征显著下降(P=.0054),归因于胶原分散。
- 血液相关光谱特征升高(P=.0372)。
- 脂质类分子相关特征升高(P=.0273)。
- 非负最小二乘模型显示胶原贡献随时间至分娩下降、血液贡献升高、脂质贡献变化。
临床怎么用
- 作者认为体内拉曼光谱可能成为客观评估宫颈、潜在指导分娩临床管理的无创工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Biochemical cervical change during labor is not well understood, in part, because of a dearth of technologies capable of safely probing the pregnant cervix in vivo. The need for such a technology is 2-fold: (1) to gain a mechanistic understanding of the cervical ripening and dilation process and (2) to provide an objective method for evaluating the cervical state to guide clinical decision-making. Raman spectroscopy demonstrates the potential to meet this need, as it is a noninvasive optical technique that can sensitively detect alterations in tissue components, such as extracellular matrix proteins, lipids, nucleic acids, and blood, which have been previously established to change during the cervical remodeling process. OBJECTIVE: We sought to demonstrate that Raman spectroscopy can longitudinally monitor biochemical changes in the laboring cervix to identify spectral markers of impending parturition. STUDY DESIGN: Overall, 30 pregnant participants undergoing either spontaneous or induced labor were recruited. The Raman spectra were acquired in vivo at 4-hour intervals throughout labor until rupture of membranes using a Raman system with a fiber-optic probe. Linear mixed-effects models were used to determine significant (P<.05) changes in peak intensities or peak ratios as a function of time to delivery in the study population. A nonnegative least-squares biochemical model was used to extract the changing contributions of specific molecule classes over time. RESULTS: We detected multiple biochemical changes during labor, including (1) significant decreases in Raman spectral features associated with collagen and other extracellular matrix proteins (P=.0054) attributed to collagen dispersion, (2) an increase in spectral features associated with blood (P=.0372), and (3) an increase in features indicative of lipid-based molecules (P=.0273). The nonnegative least-squares model revealed a decrease in collagen contribution with time to delivery, an increase in blood contribution, and a change in lipid contribution. CONCLUSION: Our findings have demonstrated that in vivo Raman spectroscopy is sensitive to multiple biochemical remodeling changes in the cervix during labor. Furthermore, in vivo Raman spectroscopy may be a valuable noninvasive tool for objectively evaluating the cervix to potentially guide clinical management of labor.
引用
- Masson LE, O'Brien CM, Gautam R, et al. In vivo Raman spectroscopy monitors cervical change during labor. Am J Obstet Gynecol. 2022. PMID: 35189092. doi:10.1016/j.ajog.2022.02.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。