比较估计胎儿体重曲线在识别伴不良结局的小于胎龄儿和大于胎龄儿中的性能:一项法国基于人群的研究
该法国2016年全国代表性观察性研究纳入9940例单胎活产,比较7种描述性及3种规定性估计胎儿体重曲线在孕30-35周超声识别伴不良结局的小于胎龄儿(SGA)和大于胎龄儿(LGA)的性能。SGA和LGA伴不良结局分别占2.1%和1.1%。各曲线灵敏度与特异度差异明显,受试者工作特征曲线下面积0.62-0.74,预测能力低至中等。
要点
- SGA和LGA伴不良结局分别占2.1%和1.1%。
- 描述性曲线识别SGA和LGA的灵敏度29-65%、特异度84-96%。
- 规定性曲线灵敏度27-60%、特异度83-96%,受试者工作特征曲线下面积0.62-0.74。
核心结论
- 描述性和规定性估计胎儿体重曲线性能差异明显,凸显评估其识别高危胎儿能力的重要性。
研究设计与样本
- 法国2016年全国代表性观察性研究,纳入9940例孕30-35周接受超声的单胎活产。
- 比较三种规定性曲线(INTERGROWTH-21st、世界卫生组织(WHO)、美国国家儿童健康与人类发展研究所(NICHD))、四种描述性曲线(Hadlock、胎儿医学基金会、两种法国曲线)及一种法国定制生长模型(Epopé)。
主要发现
- SGA和LGA伴不良结局分别占2.1%和1.1%。
- 描述性曲线以估计胎儿体重<第10百分位和>第90百分位识别SGA和LGA伴不良结局的灵敏度29-65%、特异度84-96%;规定性曲线灵敏度27-60%、特异度83-96%。
- WHO和法国曲线最接近估计胎儿体重分布,对SGA和LGA在灵敏度与特异度间取得平衡。
- INTERGROWTH-21st和Epopé对SGA灵敏度低而对LGA灵敏度高。
- 受试者工作特征曲线下面积0.62-0.74,诊断比值比7-16。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To compare the performance of estimated fetal weight (EFW) charts at the third trimester ultrasound for detecting small- and large-for-gestational age (SGA/LGA) newborns with adverse outcomes. DESIGN: Nationally representative observational study. SETTING: French maternity units in 2016. POPULATION: 9940 singleton live births with an ultrasound between 30 and 35 weeks of gestation. METHODS: We compared three prescriptive charts (INTERGROWTH-21st, World Health Organization (WHO), Eunice Kennedy Shriver National Institute of Child Health and Human Development [NICHD]), four descriptive charts (Hadlock, Fetal Medicine Foundation, two French charts) and a French customised growth model (Epopé). MAIN OUTCOME MEASURES: SGA and LGA (birthweights <10th and >90th percentiles) associated with adverse outcomes (low Apgar score, delivery-room resuscitation, neonatal unit admission). RESULTS: 2.1% and 1.1% of infants had SGA and LGA and adverse outcomes, respectively. The sensitivity and specificity for detecting these infants with an EFW <10th and >90th percentile varied from 29-65% and 84-96% for descriptive charts versus 27-60% and 83-96% for prescriptive charts. WHO and French charts were closest to the EFW distribution, yielding a balance between sensitivity and specificity for SGA and LGA births. INTERGROWTH-21st and Epopé had low sensitivity for SGA with high sensitivity for LGA. Areas under the receiving operator characteristics curve ranged from 0.62 to 0.74, showing low to moderate predictive ability, and diagnostic odds ratios varied from 7 to 16. CONCLUSION: Marked differences in the performance of descriptive as well as prescriptive EFW charts highlight the importance of evaluating them for their ability to detect high-risk fetuses. TWEETABLE ABSTRACT: Choice of growth chart strongly affected identification of high-risk fetuses at the third trimester ultrasound.
引用
- Monier I, Ego A, Benachi A, et al. Comparison of the performance of estimated fetal weight charts for the detection of small- and large-for-gestational age newborns with adverse outcomes: a French population-based study. BJOG. 2021. PMID: 34797926. doi:10.1111/1471-0528.17021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。