无标记无创光学分析检测植入前胚胎内细胞团非整倍体
研究用高光谱自发荧光显微镜,在小鼠胚胎内细胞团(ICM)中区分整倍体与非整倍体细胞,并以已知核型的人原代成纤维细胞和小鼠胚胎验证。结果显示非整倍体细胞光氧化还原比(ORR)显著降低,数学分析可实现多组分离,曲线下面积(AUC)为0.87至0.99。作者认为该无创光学方法可能成为胚胎分析的新诊断手段,但需在人胚胎及大动物中验证后方可临床实施。
要点
- 高光谱自发荧光显微镜可区分小鼠囊胚ICM的整倍体与非整倍体细胞。
- 非整倍体人成纤维细胞和小鼠卵裂球ORR显著降低(P < 0.05)。
- 该方法在临床实施前需人胚胎及大动物验证。
核心结论
- 高光谱自发荧光显微镜能区分小鼠囊胚ICM的整倍体与非整倍体细胞,并可能成为胚胎分析的新诊断方法。
- 作者认为该方法在临床实施前需在人胚胎及大动物中进一步验证。
研究设计与样本
- 采用已知核型的人原代成纤维细胞(整倍体n = 467;非整倍体n = 969;4-6次独立重复)和小鼠胚胎模型进行高光谱成像。
- 小鼠八细胞期卵裂球(5次独立重复:对照n = 39;reversine处理n = 44)及嵌合囊胚(8次独立重复:对照n = 34;reversine n = 34;1:1对照:reversine n = 30;1:3对照:reversine n = 37)用于成像。
- 机械分离对照与reversine处理胚胎的ICM,全基因组测序确认核型(整倍体n = 13;非整倍体n = 9)。
主要发现
- 非整倍体人成纤维细胞和小鼠卵裂球中NAD(P)H相对丰度增加、黄素减少,导致ORR显著降低(P < 0.05)。
- 数学分析分离整倍体与非整倍体人成纤维细胞的AUC为0.97。
- 数学分析分离对照与reversine处理小鼠卵裂球的AUC为0.99。
- 数学分析分离对照与reversine处理嵌合囊胚的AUC为0.87,分离1:1与1:3嵌合囊胚的AUC为0.88。
- 数学分析分离确认的整倍体与非整倍体小鼠囊胚ICM的AUC为0.93。
关键数值与推荐
- 非整倍体细胞ORR降低,定义为黄素/[NAD(P)H + 黄素],基于自发荧光信号推断。
- 整倍体与非整倍体人成纤维细胞分离AUC为0.97。
- 对照与reversine处理小鼠卵裂球分离AUC为0.99。
- 对照与reversine处理嵌合囊胚分离AUC为0.87。
- 1:1与1:3嵌合囊胚分离AUC为0.88;确认的整倍体与非整倍体小鼠囊胚ICM分离AUC为0.93。
临床怎么用
- 作者认为该无创光学方法可能成为胚胎分析的新诊断手段,但尚未推荐临床使用。
- 作者指出该方法在小鼠中显示安全,但在临床实施前需在大动物中进一步验证,并需在人胚胎中确认。
局限性
- 虽能区分小鼠囊胚ICM的整倍体与非整倍体,但需在人胚胎中确认该方法。
- 该方法在小鼠中显示安全,但在临床实施前需在大动物中进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY QUESTION: Can label-free, non-invasive optical imaging by hyperspectral autofluorescence microscopy discern between euploid and aneuploid cells within the inner cell mass (ICM) of the mouse preimplantation embryo? SUMMARY ANSWER: Hyperspectral autofluorescence microscopy enables discrimination between euploid and aneuploid ICM in mouse embryos. WHAT IS KNOWN ALREADY: Euploid/aneuploid mosaicism affects up to 17.3% of human blastocyst embryos with trophectoderm biopsy or spent media currently utilized to diagnose aneuploidy and mosaicism in clinical in vitro fertilization. Based on their design, these approaches will fail to diagnose the presence or proportion of aneuploid cells within the foetal lineage ICM of some blastocyst embryos. STUDY DESIGN, SIZE, DURATION: The impact of aneuploidy on cellular autofluorescence and metabolism of primary human fibroblast cells and mouse embryos was assessed using a fluorescence microscope adapted for imaging with multiple spectral channels (hyperspectral imaging). Primary human fibroblast cells with known ploidy were subjected to hyperspectral imaging to record native cell fluorescence (4-6 independent replicates, euploid n = 467; aneuploid n = 969). For mouse embryos, blastomeres from the eight-cell stage (five independent replicates: control n = 39; reversine n = 44) and chimeric blastocysts (eight independent replicates: control n = 34; reversine n = 34; 1:1 (control:reversine) n = 30 and 1:3 (control:reversine) n = 37) were utilized for hyperspectral imaging. The ICM from control and reversine-treated embryos were mechanically dissected and their karyotype confirmed by whole genome sequencing (n = 13 euploid and n = 9 aneuploid). PARTICIPANTS/MATERIALS, SETTING, METHODS: Two models were employed: (i) primary human fibroblasts with known karyotype and (ii) a mouse model of embryo aneuploidy where mouse embryos were treated with reversine, a reversible spindle assembly checkpoint inhibitor, during the four- to eight-cell division. Individual blastomeres were dissociated from control and reversine-treated eight-cell embryos and either imaged directly or used to generate chimeric blastocysts with differing ratios of control:reversine-treated cells. Individual blastomeres and embryos were interrogated by hyperspectral imaging. Changes in cellular metabolism were determined by quantification of metabolic co-factors (inferred from their autofluorescence signature): NAD(P)H and flavins with the subsequent calculation of the optical redox ratio (ORR: flavins/[NAD(P)H + flavins]). Autofluorescence signals obtained from hyperspectral imaging were examined mathematically to extract features from each cell/blastomere/ICM. This was used to discriminate between different cell populations. MAIN RESULTS AND THE ROLE OF CHANCE: An increase in the relative abundance of NAD(P)H and decrease in flavins led to a significant reduction in the ORR for aneuploid cells in primary human fibroblasts and reversine-treated mouse blastomeres (P < 0.05). Mathematical analysis of endogenous cell autofluorescence achieved separation between (i) euploid and aneuploid primary human fibroblast cells, (ii) control and reversine-treated mouse blastomeres cells, (iii) control and reversine-treated chimeric blastocysts, (iv) 1:1 and 1:3 chimeric blastocysts and (v) confirmed euploid and aneuploid ICM from mouse blastocysts. The accuracy of these separations was supported by receiver operating characteristic curves with areas under the curve of 0.97, 0.99, 0.87, 0.88 and 0.93, respectively. We believe that the role of chance is low as mathematical features separated euploid from aneuploid in both human fibroblasts and ICM of mouse blastocysts. LARGE SCALE DATA: N/A. LIMITATIONS, REASONS FOR CAUTION: Although we were able to discriminate between euploid and aneuploid ICM in mouse blastocysts, confirmation of this approach in human embryos is required. While we show this approach is safe in mouse, further validation is required in large animal species prior to implementation in a clinical setting. WIDER IMPLICATIONS OF THE FINDINGS: We have developed an original, accurate and non-invasive optical approach to assess aneuploidy within the ICM of mouse embryos in the absence of fluorescent tags. Hyperspectral autofluorescence imaging was able to discriminate between euploid and aneuploid human fibroblast and mouse blastocysts (ICM). This approach may potentially lead to a new diagnostic for embryo analysis. STUDY FUNDING/COMPETING INTEREST(S): K.R.D. is supported by a Mid-Career Fellowship from the Hospital Research Foundation (C-MCF-58-2019). This study was funded by the Australian Research Council Centre of Excellence for Nanoscale Biophotonics (CE140100003) and the National Health and Medical Research Council (APP2003786). The authors declare that there is no conflict of interest.
引用
- Tan TCY, Mahbub SB, Campbell JM, et al. Non-invasive, label-free optical analysis to detect aneuploidy within the inner cell mass of the preimplantation embryo. Hum Reprod. 2021. PMID: 34741175. doi:10.1093/humrep/deab233
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。