文献速递妇科

经会阴超声容积中最小裂孔尺寸切面的自动识别与分割

Automatic identification and segmentation of slice of minimal hiatal dimensions in transperineal ultrasound volumes.
PubMed 文献 · Ultrasound Obstet Gynecol · 2022-01-01

本研究在116例有症状盆腔器官脱垂(POP)女性的经会阴超声(TPUS)容积中手动选择最小裂孔尺寸切面(SMHD)并分割泌尿生殖裂孔(UH),训练两种深度学习算法实现自动选择与分割,在30个容积的测试集上评估。手动与自动选择的SMHD平均绝对距离为0.20 cm,所有UH分割的Dice相似指数(DSI)均高于0.85,UH面积、前后径和冠状径的组内相关系数(ICC)分别为0.94(95% CI 0.87-0.97)、0.92(95% CI 0.78-0.97)和0.82(95% CI 0.66-0.91)。结论认为算法可可靠自动选择SMHD并分割UH,可集成于TPUS设备软件。

要点

  • 手动与自动选择的SMHD平均绝对距离为0.20 cm。
  • 手动与自动UH分割的DSI均高于0.85。
  • UH面积、前后径、冠状径的ICC分别为0.94、0.92、0.82。

核心结论

  • 深度学习算法可在有症状POP女性的TPUS容积中可靠地自动选择SMHD并分割UH。

研究设计与样本

  • 在116例有症状POP女性的TPUS容积中手动选择SMHD并分割UH,用于训练两种深度学习算法。
  • 第一种算法估计SMHD位置,基于该估计选择切面并输入第二种算法进行UH自动分割,自动计算UH面积(UHA)、前后径(APD)和冠状径(CD)。
  • 在30个TPUS容积的测试集上评估手动与自动选择的SMHD平均绝对距离、手动与自动UH分割的DSI以及手动与自动UH测量的ICC。

主要发现

  • 手动与自动选择的SMHD平均绝对距离为0.20 cm。
  • 所有手动与自动UH分割的DSI值均高于0.85。
  • 手动与自动UH测量的ICC:UHA为0.94(95% CI 0.87-0.97),APD为0.92(95% CI 0.78-0.97),CD为0.82(95% CI 0.66-0.91)。

临床怎么用

  • 作者认为这些算法可集成于TPUS设备软件,从而减少临床分析时间并简化TPUS数据用于研究和临床目的的检查。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To develop and validate a tool for automatic selection of the slice of minimal hiatal dimensions (SMHD) and segmentation of the urogenital hiatus (UH) in transperineal ultrasound (TPUS) volumes. METHODS: Manual selection of the SMHD and segmentation of the UH was performed in TPUS volumes of 116 women with symptomatic pelvic organ prolapse (POP). These data were used to train two deep-learning algorithms. The first algorithm was trained to provide an estimation of the position of the SMHD. Based on this estimation, a slice was selected and fed into the second algorithm, which performed automatic segmentation of the UH. From this segmentation, measurements of the UH area (UHA), anteroposterior diameter (APD) and coronal diameter (CD) were computed automatically. The mean absolute distance between manually and automatically selected SMHD, the overlap (dice similarity index (DSI)) between manual and automatic UH segmentation and the intraclass correlation coefficient (ICC) between manual and automatic UH measurements were assessed on a test set of 30 TPUS volumes. RESULTS: The mean absolute distance between manually and automatically selected SMHD was 0.20 cm. All DSI values between manual and automatic UH segmentations were above 0.85. The ICC values between manual and automatic UH measurements were 0.94 (95% CI, 0.87-0.97) for UHA, 0.92 (95% CI, 0.78-0.97) for APD and 0.82 (95% CI, 0.66-0.91) for CD, demonstrating excellent agreement. CONCLUSIONS: Our deep-learning algorithms allowed reliable automatic selection of the SMHD and UH segmentation in TPUS volumes of women with symptomatic POP. These algorithms can be implemented in the software of TPUS machines, thus reducing clinical analysis time and simplifying the examination of TPUS data for research and clinical purposes. © 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. van den Noort F, Manzini C, van der Vaart CH, et al. Automatic identification and segmentation of slice of minimal hiatal dimensions in transperineal ultrasound volumes. Ultrasound Obstet Gynecol. 2022. PMID: 34767663. doi:10.1002/uog.24810