前穹窿/宫颈区域定量血管化与胎盘植入谱系及术中出血的关联
前瞻性研究纳入117例疑似胎盘植入谱系(PAS)的前置胎盘患者,用经阴道彩色多普勒超声定量分析前穹窿/宫颈(AFC)区域血管化(QV)。QV≥8.5%与PAS、穿透性植入及严重术中出血风险升高相关,受试者工作特征曲线下面积为0.821。
要点
- QV≥8.5%与PAS风险升高相关(OR 14.9,95%CI 4.7–47.0)。
- QV≥8.5%与严重术中出血(>1500 mL)风险升高相关(OR 3.9,95%CI 1.8–8.7)。
- QV诊断PAS的曲线下面积为0.821,阴性预测值为50.0%。
核心结论
- AFC区域QV≥8.5%可识别PAS及严重术中出血风险升高的患者。
- 尽管阴性预测值有限,AFC区域QV评估可能为PAS的临床管理和手术规划提供有价值的信息。
研究设计与样本
- 前瞻性研究,纳入2021年12月至2025年6月在美国德克萨斯大学休斯顿健康科学中心转诊的可疑PAS的前置胎盘患者,共117例。
主要发现
- 组织病理学确诊PAS 89例(76.1%),其中植入性胎盘11例、侵入性胎盘55例、穿透性胎盘23例。
- 109例获得可靠的术中出血量估计,其中严重术中出血(>1500 mL)53例(48.6%)。
- QV区分确诊PAS与非PAS的受试者工作特征曲线下面积为0.821(95%CI 0.739–0.886)。
- QV≥8.5%与PAS风险升高相关(OR 14.9,95%CI 4.7–47.0;P<0.0001),与穿透性胎盘风险升高相关(OR 55.5,95%CI 10.1–305.7;P<0.0001)。
- QV≥8.5%与严重术中出血风险升高相关(OR 3.9,95%CI 1.8–8.7;P=0.0009),与分娩时需要≥4单位血制品风险升高相关(OR 4.6,95%CI 2.0–10.4;P=0.0002)。
关键数值与推荐
- QV预测PAS的最佳截断值为8.5%,灵敏度70.5%(95%CI 59.8–79.7%),特异度89.7%(95%CI 68.3–96.1%)。
- QV截断值8.5%的阳性预测值为93.9%(95%CI 86.1–97.5%),阴性预测值为50.0%(95%CI 40.3–57.8%)。
临床怎么用
- QV值未提供给临床医生,也未用于临床决策。
- 作者认为AFC区域QV评估可能为PAS的临床管理和手术规划提供有价值的信息。
提炼说明
- 本条依据论文摘要整理;摘要未涉及「局限性」,故未列出该栏;全文请点「阅读原文」。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
ABSTRACT Objectives We aimed to evaluate a quantitative method for analyzing vascularization in the anterior fornix/cervix (AFC) region in women at risk of placenta accreta spectrum (PAS). The primary aim was to evaluate the association between quantitative vascularization (QV) and severity of PAS (determined by histopathology) and to estimate the optimal QV cut-off value to predict PAS. A secondary aim was to evaluate the association of QV with severe intraoperative blood loss (IOBL). Methods This was a prospective study including patients with anterior placenta previa referred for suspected PAS at the University of Texas Health Science Center at Houston, TX, USA, between December 2021 and June 2025. Transvaginal ultrasound with color Doppler (with standardized settings) was performed to visualize the cervix and the lower uterine segment in the midsagittal plane. The prenatal diagnosis of high risk for PAS was based on ultrasound features including loss of the uteroplacental interface, the presence of placental lacunae, increased vascularization and abnormal bladder wall. For QV assessment, a videoclip was acquired, in which the AFC region was defined and post-processing analysis was used to estimate the percentage of color pixels within the AFC region in each frame. The mean value across all frames was defined as the QV value. QV values were not provided to clinicians and were not used for clinical decisions. Associations between QV and PAS, depth of implantation, IOBL and units of blood products transfused were evaluated, as well as the ability of QV to discriminate between patients with and those without PAS. Results A total of 117 patients were included. PAS was confirmed histopathologically in 89 (76.1%) patients (placenta accreta, n = 11; placenta increta, n = 55; placenta percreta, n = 23). A reliable estimation of IOBL was obtained in 109 patients and severe IOBL (> 1500 mL) occurred in 53 (48.6%) of these cases. The area under the receiver-operating-characteristics curve, demonstrating the ability of QV to discriminate between cases with and those without confirmed PAS, was 0.821 (95% CI, 0.739–0.886). The optimal QV cut-off value was 8.5%, yielding a sensitivity of 70.5% (95% CI, 59.8–79.7%), specificity of 89.7% (95% CI, 68.3–96.1%), positive predictive value of 93.9% (95% CI, 86.1–97.5%) and negative predictive value of 50.0% (95% CI, 40.3–57.8%). QV ≥ 8.5% was associated with increased odds of PAS (odds ratio (OR), 14.9 (95% CI, 4.7–47.0); P < 0.0001), placenta percreta (OR, 55.5 (95% CI, 10.1-305.7); P < 0.0001), severe IOBL (OR, 3.9 (95% CI, 1.8-8.7); P = 0.0009) and the need for ≥ 4 units of blood products during delivery (OR, 4.6 (95% CI, 2.0-10.4); P = 0.0002). Conclusion QV ≥ 8.5% of the AVC region identifies patients at increased risk for PAS and for severe IOBL. Although the negative predictive value was limited, QV assessment of the AFC region may provide valuable information to support clinical management and surgical planning in PAS. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Ultrasound in Obstetrics and Gynecology:Association of quantitative vascularization of the anterior fornix/cervix region with placenta accreta spectrum and associated intraoperative hemorrhage
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。