文献速递母胎医学

选择性筛查超声检测小于胎龄儿的效能:DESiGN试验嵌套队列研究

The Performance of Selective Screening Ultrasound to Detect the Small‐for‐Gestational‐Age Foetus: A Prospective Cohort Study Nested Within the DESiGN Randomised Control Trial
RSS 订阅 · BJOG · 2026-03-12

分析末次选择性筛查超声估计胎儿体重低于第10百分位预测出生体重低于第10百分位的效能。结果显示妊娠34周后及扫描距分娩间隔超过4周时检测效能明显下降。

要点

  • 34周以后超声估计胎儿体重低于第10百分位检出SGA的效能下降。
  • 扫描距分娩超过4周时,34至37+6周超声检出SGA效能极差。
  • 选择性人群晚期妊娠超声估重检出SGA效能有限,解读需结合扫描孕周与间隔。

核心结论

  • 在选择性人群中,妊娠晚期超声估计胎儿大小以检出出生时SGA的效能较差。
  • 末次选择性筛查超声EFW低于第10百分位正确识别SGA的效能自34周起下降,并随扫描距分娩间隔延长而降低。

研究设计与样本

  • 采用前瞻性队列研究设计,分析来自DESiGN试验的超声数据。
  • DESiGN试验是首个评估生长评估方案对产前检出SGA影响的整群随机对照试验。

主要发现

  • EFW低于第10百分位预测出生体重低于第10百分位的检测效能随扫描孕周增加和扫描距分娩间隔延长而下降。
  • 妊娠34至37+6周且在分娩前超过4周进行的超声,敏感性为4.0%,95%CI为3.8至4.1。

关键数值与推荐

  • EFW采用Hadlock 1991公式计算,低于第10百分位为阳性标准。
  • 出生体重低于第10百分位依据1990年英国人口图表判定。
  • 34至37+6周且距分娩超过4周的扫描敏感性为4.0%,95%CI为3.8至4.1。

临床怎么用

  • 解读晚期妊娠超声估重结果时需考虑扫描孕周及距分娩的时间间隔。
  • 扫描距分娩超过4周时,34至37+6周超声检出SGA的阴性结果解释需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

ABSTRACT Objective Evidence on the performance of foetal growth ultrasound parameters to detect the Small-for-Gestational-Age (SGA) foetus for a selective cohort is limited. We report the performance of estimated foetal weight under the 10th percentile (EFW < 10th) at the last selective screening ultrasound to detect SGA based on gestational age of scan and scan to birth interval. Design We performed a prospective cohort study to analyse ultrasound data obtained from the DESiGN trial. Setting The DESiGN trial was the first cluster randomised controlled trial to evaluate the impact of the Growth Assessment Protocol (GAP) on antenatal detection of SGA. Population Ninety-four thousand, nine hundred twenty-five women included in DESiGN who had at least 1 ultrasound scan after 24 weeks' gestational age with complete ultrasound data underwent analysis. Methods Test performance characteristics of EFW (by Hadlock 1991) < 10th percentile to predict birthweight < 10th percentile (by 1990 UK Population Charts) were reported at different gestational ages of scan categories and scan to birth intervals. Results The performance of EFW < 10th percentile at the last selective screening ultrasound to correctly identify SGA declined from 34 weeks and with increasing scan to birth intervals. A scan between 34 and 37 + 6 weeks' gestation more than 4 weeks prior to birth had a particularly poor performance (sensitivity 4.0%, 95% CI 3.8–4.1). Conclusions In a selected population, the performance of late third-trimester ultrasound estimation of foetal size to detect SGA at birth is poor.

来源:BJOG,查看原文。版权归原作者所有。

引用

  1. BJOG:The Performance of Selective Screening Ultrasound to Detect the Small‐for‐Gestational‐Age Foetus: A Prospective Cohort Study Nested Within the DESiGN Randomised Control Trial

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。