Home › Clinical Tools › Insulin params

🧬 Insulin Correction Factor / Carb Ratio

UseEnter total daily dose and select rapid- or short-acting insulin; the tool returns ISF (mmol/L and mg/dL per …

Loading calculator…

SourceWalsh J, Roberts R, Bailey T. Guidelines for optimal bolus calculator settings in adults. J Diabete…

Runs locally in your browser (no PHI uploaded). For licensed clinicians — not a substitute for clinical judgement.
Stored on this device for revisit reminders

This-shift next steps

After scoring: open the scene pack, peer scores, and the matching pathway. Local reference — no HIS write.

Score + version; reference only — not a substitute for care · no HIS write

Paste the link in Slack, Teams, X, or LinkedIn — the preview image comes from this page’s Open Graph card.

Methodology · worked example, guidelines & full notes
Clinical takeaway

The 1800/500 ('rapid') and 1500/450 ('regular') rules are starting estimates derived from TDD, not validated individual targets — always refine empirically. (original synthesis · not guideline verbatim)

When to use

Enter total daily dose and select rapid- or short-acting insulin; the tool returns ISF (mmol/L and mg/dL per unit) and ICR (grams per unit). Titrate both against the patient's own glucose monitoring.

How it works

Rapid-acting: ISF = 1800/TDD (mg/dL per U), ICR = 500/TDD (g per U). Short-acting: ISF = 1500/TDD, ICR = 450/TDD. ISF in mmol/L = (mg/dL value)/18.

Key points

  • The 1800/500 ('rapid') and 1500/450 ('regular') rules are starting estimates derived from TDD, not validated individual targets — always refine empirically. (original synthesis · not guideline verbatim)
  • Both factors scale inversely with TDD, so a recent dose change invalidates a previously derived ISF/ICR.
  • Apply with caution in hypoglycemia-prone patients; specialist supervision and structured education underpin safe carb counting.

References

Worked calculation

The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.

Total daily insulin dose TDD40 U/day
Insulin typeRapid-acting (1800/500)

→Correction factor ISF2.5mmol/L/U

  • ISF:45 mg/dL/U
  • Carb ratio ICR:1 U : 13 g
  • Source:1800/1500 and 500/450 are empirical rules; coefficients differ between sources. Methods compared in Davidson 2008 (PMID 19158048)
Total daily insulin dose TDD40 U/day
Insulin typeRegular/short-acting (1500/450)

→Correction factor ISF2.1mmol/L/U

  • ISF:38 mg/dL/U
  • Carb ratio ICR:1 U : 11 g
  • Source:1800/1500 and 500/450 are empirical rules; coefficients differ between sources. Methods compared in Davidson 2008 (PMID 19158048)
Verification & sources · governance
FAQ

Frequently asked questions

What are the limits and cautions when using Insulin Correction Factor / Carb Ratio?
For licensed clinicians and clinical researchers. Interpret results with history, investigations and local protocols; not a diagnosis or prescription, and not a substitute for multidisciplinary decision-making or local guidelines.
Does Insulin Correction Factor / Carb Ratio upload patient data? Where is it calculated?
Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.
How is Insulin Correction Factor / Carb Ratio calculated in practice? Can you show a worked example?
Inputs: Total daily insulin dose TDD 40 U/day, Insulin type Rapid-acting (1800/500) → Result: Correction factor ISF 2.5 mmol/L/U(ISF: 45 mg/dL/U, Carb ratio ICR: 1 U : 13 g, Source: 1800/1500 and 500/450 are empirical rules; coefficients differ between sources. Methods compared in Davidson 2008 (PMID 19158048)) Inputs: Total daily insulin dose TDD 40 U/day, Insulin type Regular/short-acting (1500/450) → Result: Correction factor ISF 2.1 mmol/L/U(ISF: 38 mg/dL/U, Carb ratio ICR: 1 U : 11 g, Source: 1800/1500 and 500/450 are empirical rules; coefficients differ between sources. Methods compared in Davidson 2008 (PMID 19158048))
Related tools