📐 Spondylolisthesis Slip Percentage & Meyerding Grade
UseSpine imaging: standing full-spine films, flexion/extension views, CT/MRI — scoliosis follow-up, adult deform…
SourceMeyerding HW. Spondylolisthesis. Surg Gynecol Obstet 1932;54:371-377
This-shift next steps
After scoring: open the scene pack, peer scores, and the matching pathway. Local reference — no HIS write.
Paste the link in Slack, Teams, X, or LinkedIn — the preview image comes from this page’s Open Graph card.
Methodology · worked example, guidelines & full notes
Standing lateral lumbar radiograph (± flexion/extension).
When to use
Spine imaging: standing full-spine films, flexion/extension views, CT/MRI — scoliosis follow-up, adult deformity, stenosis reporting and surgical planning.
How it works
Slip percentage < 25%: Meyerding grade I Slip percentage 25–50%: grade II Slip percentage 50–75%: grade III (high-grade) Slip percentage 75–100%: grade IV Slip percentage > 100%: grade V (spondyloptosis)
Key points
- Standing lateral lumbar radiograph (± flexion/extension).
- Each value is graded against published reference ranges.
- Measurement technique and positioning change the numbers — compare like with like on follow-up.
- Part of the YuanDoctor MSK measurement topic.
References
- Meyerding HW. Spondylolisthesis. Surg Gynecol Obstet 1932;54:371-377
Worked calculation
The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.
| Slip distance D | 12 mm |
|---|---|
| Lower endplate AP width W | 42 mm |
→Slip percentage28.6%
- Slip percentage:28.6 % → 25–50%: grade II
Verification & sources · governance
FAQ
Frequently asked questions
- What are the limits and cautions when using Spondylolisthesis Slip Percentage & Meyerding Grade?
- For licensed clinicians and clinical researchers. Interpret results with history, investigations and local protocols; not a diagnosis or prescription, and not a substitute for multidisciplinary decision-making or local guidelines.
- Does Spondylolisthesis Slip Percentage & Meyerding Grade upload patient data? Where is it calculated?
- Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.
- How is Spondylolisthesis Slip Percentage & Meyerding Grade calculated in practice? Can you show a worked example?
- Inputs: Slip distance D 12 mm, Lower endplate AP width W 42 mm → Result: Slip percentage 28.6 %(Slip percentage: 28.6 % → 25–50%: grade II)