Home › Clinical Tools › Prostate MRI Report

📝 Prostate mpMRI Structured Report (PI-RADS v2.1 + PSAD + EPE)

UseProstate MRI reporting and harmonized structure between urology and radiology.

Loading calculator…

SourceTurkbey B, et al. Eur Urol 2019;76:340-351

Runs locally in your browser (no PHI uploaded). For licensed clinicians — not a substitute for clinical judgement.
Stored on this device for revisit reminders

This-shift next steps

After scoring: open the scene pack, peer scores, and the matching pathway. Local reference — no HIS write.

Score + version; reference only — not a substitute for care · no HIS write

Paste the link in Slack, Teams, X, or LinkedIn — the preview image comes from this page’s Open Graph card.

Methodology · worked example, guidelines & full notes
Clinical takeaway

Ellipsoid ×0.52.

When to use

Prostate MRI reporting and harmonized structure between urology and radiology.

How it works

Volume = L × W × H × 0.52; PSAD = PSA / volume; EPE grade 0–3 (Mehralivand).

Key points

  • Ellipsoid ×0.52.
  • PSAD with PI-RADS.
  • EPE per Mehralivand.
  • Always report SV, nodes, bone.

References

Worked calculation

The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.

PSA7.8 ng/mL
Prostate length4.4 cm
Width4.9 cm
Height3.5 cm
Index lesion PI-RADSPI-RADS 3
Zonetransition zone
Sideright
Levelmid-gland
Lesion maximum diameter14 mm
Lesion ADC (optional)720 µm²/s
Extraprostatic extension (Mehralivand)Grade 1: capsular contact ≥1.5 cm or bulge/irregularity
Seminal vesicle invasionNo
Pelvic nodesNone suspicious
Pelvic bonesNo suspicious lesion

→PI-RADS3· PSAD 0.20

  • Report block:Prostate 4.4 × 4.9 × 3.5 cm, volume 39.2 mL, PSA 7.8 ng/mL, PSAD 0.20. A lesion in the right transition zone at the mid-gland, 14 mm, ADC 720 µm²/s, PI-RADS 3, possible EPE (grade 1). Seminal vesicles not involved; no suspicious pelvic nodes; no suspicious pelvic bone lesion.
  • Impression / recommendation:PI-RADS 3, possible EPE (grade 1). PI-RADS 3 with PSAD 0.10–0.20: intermediate; decide biopsy vs surveillance with clinical factors and patient preference.
  • Volume formula:4.4×4.9×3.5×0.52 = 39.2 mL
PSA7.8 ng/mL
Prostate length4.4 cm
Width4.9 cm
Height3.5 cm
Index lesion PI-RADSPI-RADS 1
Zoneperipheral zone
Sideleft
Levelbase
Lesion maximum diameter14 mm
Lesion ADC (optional)720 µm²/s
Extraprostatic extension (Mehralivand)Grade 0: none
Seminal vesicle invasionNo
Pelvic nodesNone suspicious
Pelvic bonesNo suspicious lesion

→PI-RADS1· PSAD 0.20

  • Report block:Prostate 4.4 × 4.9 × 3.5 cm, volume 39.2 mL, PSA 7.8 ng/mL, PSAD 0.20. No PI-RADS ≥3 lesion (overall PI-RADS 1). Seminal vesicles not involved; no suspicious pelvic nodes; no suspicious pelvic bone lesion.
  • Impression / recommendation:PI-RADS 1. PI-RADS 1–2 with PSAD <0.20: low csPCa risk; immediate biopsy can often be avoided.
  • Volume formula:4.4×4.9×3.5×0.52 = 39.2 mL
Verification & sources · governance
FAQ

Frequently asked questions

What are the limits and cautions when using Prostate mpMRI Structured Report (PI-RADS v2.1 + PSAD + EPE)?
For licensed clinicians and clinical researchers. Interpret results with history, investigations and local protocols; not a diagnosis or prescription, and not a substitute for multidisciplinary decision-making or local guidelines.
Does Prostate mpMRI Structured Report (PI-RADS v2.1 + PSAD + EPE) upload patient data? Where is it calculated?
Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.
How is Prostate mpMRI Structured Report (PI-RADS v2.1 + PSAD + EPE) calculated in practice? Can you show a worked example?
Inputs: PSA 7.8 ng/mL, Prostate length 4.4 cm, Width 4.9 cm, Height 3.5 cm, Index lesion PI-RADS PI-RADS 3, Zone transition zone, Side right, Level mid-gland… → Result: PI-RADS 3 · PSAD 0.20(Report block: Prostate 4.4 × 4.9 × 3.5 cm, volume 39.2 mL, PSA 7.8 ng/mL, PSAD 0.20. A lesion in the right transition zone at the mid-gland, 14 mm, ADC 720 µm²/s, PI-RADS 3, possible EPE (grade 1). Seminal vesicles not involved; no suspicious pelvic nodes; no suspicious pelvic bone lesion., Impression / recommendation: PI-RADS 3, possible EPE (grade 1). PI-RADS 3 with PSAD 0.10–0.20: intermediate; decide biopsy vs surveillance with clinical factors and patient preference., Volume formula: 4.4×4.9×3.5×0.52 = 39.2 mL) Inputs: PSA 7.8 ng/mL, Prostate length 4.4 cm, Width 4.9 cm, Height 3.5 cm, Index lesion PI-RADS PI-RADS 1, Zone peripheral zone, Side left, Level base… → Result: PI-RADS 1 · PSAD 0.20(Report block: Prostate 4.4 × 4.9 × 3.5 cm, volume 39.2 mL, PSA 7.8 ng/mL, PSAD 0.20. No PI-RADS ≥3 lesion (overall PI-RADS 1). Seminal vesicles not involved; no suspicious pelvic nodes; no suspicious pelvic bone lesion., Impression / recommendation: PI-RADS 1. PI-RADS 1–2 with PSAD <0.20: low csPCa risk; immediate biopsy can often be avoided., Volume formula: 4.4×4.9×3.5×0.52 = 39.2 mL)
Related tools