⏱️ Nodule Volume & Volume Doubling Time (VDT)

UseAssessing growth of lung nodules on follow-up CT; also usable for other lesions.

Loading calculator…

SourceCallister MEJ, et al. BTS guidelines. Thorax 2015;70 Suppl 2:ii1-ii54

Runs locally in your browser (no PHI uploaded). For licensed clinicians — not a substitute for clinical judgement.
Stored on this device for revisit reminders

This-shift next steps

After scoring: open the scene pack, peer scores, and the matching pathway. Local reference — no HIS write.

Paste the link in Slack, Teams, X, or LinkedIn — the preview image comes from this page’s Open Graph card.

Methodology · worked example, guidelines & full notes
Clinical takeaway

Growth = ≥25% volume increase.

When to use

Assessing growth of lung nodules on follow-up CT; also usable for other lesions.

How it works

V = π/6·a·b·c (sphere if only one diameter); VDT = Δt·ln2 / ln(V2/V1); change = (V2−V1)/V1.

Key points

  • Growth = ≥25% volume increase.
  • Solid VDT <400 days is suspicious.
  • 400–600 days indeterminate.
  • Subsolid nodules can have long VDTs.

References

Worked calculation

The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.

Earlier volume (software; blank to use diameters)250 mm³
Current volume (software; blank to use diameters)400 mm³
Earlier long axis8 mm
Current long axis10 mm
Interval between scans90 days
Nodule typeSolid

→Volume doubling time133days

  • Earlier / current volume:250 / 400 mm³ (software volumes)
  • Volume change:+60.0%
  • Reading:Significant growth: VDT <400 days (NELSON positive)
Verification & sources · governance
FAQ

Frequently asked questions

What are the limits and cautions when using Nodule Volume & Volume Doubling Time (VDT)?
For licensed clinicians and clinical researchers. Interpret results with history, investigations and local protocols; not a diagnosis or prescription, and not a substitute for multidisciplinary decision-making or local guidelines.
Does Nodule Volume & Volume Doubling Time (VDT) upload patient data? Where is it calculated?
Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.
How is Nodule Volume & Volume Doubling Time (VDT) calculated in practice? Can you show a worked example?
Inputs: Earlier volume (software; blank to use diameters) 250 mm³, Current volume (software; blank to use diameters) 400 mm³, Earlier long axis 8 mm, Current long axis 10 mm, Interval between scans 90 days, Nodule type Solid → Result: Volume doubling time 133 days(Earlier / current volume: 250 / 400 mm³ (software volumes), Volume change: +60.0%, Reading: Significant growth: VDT <400 days (NELSON positive))
Related tools