Home › Clinical Tools › Enhancement & Washout

📈 Multiphase Enhancement & Washout (CT HU)

UseCharacterizing liver, renal, pancreatic or adrenal lesions on multiphase CT and documenting enhancement in th…

Loading calculator…

SourceSilverman SG, et al. Bosniak Classification, Version 2019. Radiology 2019;292:475-488

Runs locally in your browser (no PHI uploaded). For licensed clinicians — not a substitute for clinical judgement.
Stored on this device for revisit reminders

This-shift next steps

After scoring: open the scene pack, peer scores, and the matching pathway. Local reference — no HIS write.

Paste the link in Slack, Teams, X, or LinkedIn — the preview image comes from this page’s Open Graph card.

Methodology · worked example, guidelines & full notes
Clinical takeaway

Renal mass ≥20 HU = enhancing.

When to use

Characterizing liver, renal, pancreatic or adrenal lesions on multiphase CT and documenting enhancement in the report.

How it works

Net = post − pre; absolute washout = (peak − last)/(peak − pre)×100; relative washout = (peak − last)/peak×100.

Key points

  • Renal mass ≥20 HU = enhancing.
  • 10–19 HU equivocal; consider MRI/CEUS.
  • Early enhancement with washout pattern.
  • Consistent ROIs are essential.

References

Worked calculation

The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.

Unenhanced HU35 HU
Arterial HU (optional)120 HU
Portal venous / nephrographic HU (optional)95 HU
Delayed HU (optional)60 HU
Lesion contextRenal mass

→Max net enhancement+85HU

  • Arterial:120 HU (net +85 HU)
  • Portal venous:95 HU (net +60 HU)
  • Delayed:60 HU (net +25 HU)
Verification & sources · governance
FAQ

Frequently asked questions

What are the limits and cautions when using Multiphase Enhancement & Washout (CT HU)?
For licensed clinicians and clinical researchers. Interpret results with history, investigations and local protocols; not a diagnosis or prescription, and not a substitute for multidisciplinary decision-making or local guidelines.
Does Multiphase Enhancement & Washout (CT HU) upload patient data? Where is it calculated?
Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.
How is Multiphase Enhancement & Washout (CT HU) calculated in practice? Can you show a worked example?
Inputs: Unenhanced HU 35 HU, Arterial HU (optional) 120 HU, Portal venous / nephrographic HU (optional) 95 HU, Delayed HU (optional) 60 HU, Lesion context Renal mass → Result: Max net enhancement +85 HU(Arterial: 120 HU (net +85 HU), Portal venous: 95 HU (net +60 HU), Delayed: 60 HU (net +25 HU))
Related tools