Home › Clinical Tools › CAD-RADS

🫀 Coronary CTA CAD-RADS 2.0 Classification

UseStandardise coronary CTA reporting and the downstream management direction.

Loading calculator…

SourceCury RC, et al. CAD-RADS 2.0 — 2022 Coronary CTA Reporting and Data System. J Cardiovasc Comput Tom…

Runs locally in your browser (no PHI uploaded). For licensed clinicians — not a substitute for clinical judgement.
Stored on this device for revisit reminders

This-shift next steps

After scoring: open the scene pack, peer scores, and the matching pathway. Local reference — no HIS write.

Score + version; reference only — not a substitute for care · no HIS write

Paste the link in Slack, Teams, X, or LinkedIn — the preview image comes from this page’s Open Graph card.

Methodology · worked example, guidelines & full notes
Clinical takeaway

Graded by the per-patient most severe luminal stenosis (segments > 1.5 mm).

When to use

Standardise coronary CTA reporting and the downstream management direction.

How it works

0 none, 1–2 non-obstructive, 3 moderate (50–69%), 4A severe (70–99%), 4B left main > 50% or 3-vessel ≥ 70%, 5 occlusion, N non-diagnostic. Modifiers: P (plaque burden), HRP, I (ischaemia), S/G/E.

Key points

  • Graded by the per-patient most severe luminal stenosis (segments > 1.5 mm).
  • CAD-RADS 3.
  • CAD-RADS 4B (high-risk anatomy)

References

Worked calculation

The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.

Most severe luminal stenosis (per-patient)50–69% moderate
Ischaemia modifier (CT-FFR/CTP)I+ positive
High-risk plaque (HRP)Yes

→CategoryCAD-RADS 3 / HRP/I+

  • Category:CAD-RADS 3: 50–69% moderate
  • Management:optimise medical therapy (GDMT)[Pending update] Some thresholds, grades and management recommendations on this page that conflict with current guidelines or are unverified are temporarily hidden pending verification against the guideline text.
  • Modifiers:HRP, I+ (included); also annotate P1–P4 plaque burden, S stent, G graft, E non-atherosclerotic as needed
Most severe luminal stenosis (per-patient)0% (no plaque/stenosis)
Ischaemia modifier (CT-FFR/CTP)Not done
High-risk plaque (HRP)Yes

→CategoryCAD-RADS 0 / HRP

  • Category:CAD-RADS 0: 0% (no plaque/stenosis)
  • Management:No obstructive CAD: no further cardiac testing; general prevention by risk factors
  • Modifiers:HRP (included); also annotate P1–P4 plaque burden, S stent, G graft, E non-atherosclerotic as needed
Verification & sources · governance
FAQ

Frequently asked questions

What are the limits and cautions when using Coronary CTA CAD-RADS 2.0 Classification?
For licensed clinicians and clinical researchers. Interpret results with history, investigations and local protocols; not a diagnosis or prescription, and not a substitute for multidisciplinary decision-making or local guidelines.
Does Coronary CTA CAD-RADS 2.0 Classification upload patient data? Where is it calculated?
Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.
How is Coronary CTA CAD-RADS 2.0 Classification calculated in practice? Can you show a worked example?
Inputs: Most severe luminal stenosis (per-patient) 50–69% moderate, Ischaemia modifier (CT-FFR/CTP) I+ positive, High-risk plaque (HRP) Yes → Result: Category CAD-RADS 3 / HRP/I+(Category: CAD-RADS 3: 50–69% moderate, Management: optimise medical therapy (GDMT)[Pending update] Some thresholds, grades and management recommendations on this page that conflict with current guidelines or are unverified are temporarily hidden pending verification against the guideline text., Modifiers: HRP, I+ (included); also annotate P1–P4 plaque burden, S stent, G graft, E non-atherosclerotic as needed) Inputs: Most severe luminal stenosis (per-patient) 0% (no plaque/stenosis), Ischaemia modifier (CT-FFR/CTP) Not done, High-risk plaque (HRP) Yes → Result: Category CAD-RADS 0 / HRP(Category: CAD-RADS 0: 0% (no plaque/stenosis), Management: No obstructive CAD: no further cardiac testing; general prevention by risk factors, Modifiers: HRP (included); also annotate P1–P4 plaque burden, S stent, G graft, E non-atherosclerotic as needed)
Related tools