Home › Clinical Tools › Breast nodule manager

🎀 Breast Nodule Manager · BI-RADS Assessment & Follow-up

UseFollow-up and biopsy triage after an ultrasound or mammography BI-RADS category.

Loading calculator…

Strata1–2 routine screening, 3 short-interval follow-up, 4–5 tissue biopsy, 6 breast specialist referral. BI-RADS i…

LimitsA benign result discordant with imaging needs re-evaluation. · This page gives no surgical or systemic-therapy plan.

SourceAmerican College of Radiology. ACR BI-RADS Atlas, 5th edition. Reston, VA: ACR; 2013

Runs locally in your browser (no PHI uploaded). For licensed clinicians — not a substitute for clinical judgement.
Stored on this device for revisit reminders

This-shift next steps

After scoring: open the scene pack, peer scores, and the matching pathway. Local reference — no HIS write.

Score + version; reference only — not a substitute for care · no HIS write

Paste the link in Slack, Teams, X, or LinkedIn — the preview image comes from this page’s Open Graph card.

Methodology · worked example, guidelines & full notes
Clinical takeaway

BI-RADS 3: short-interval follow-up.

When to use

Follow-up and biopsy triage after an ultrasound or mammography BI-RADS category.

How it works

BI-RADS likelihood: 1–2 ≈0%; 3 ≤2%; 4A >2–≤10%; 4B >10–≤50%; 4C >50–<95%; 5 ≥95%; 6 pathology-proven.

Key points

  • BI-RADS 3: short-interval follow-up.
  • BI-RADS 4–5: tissue biopsy.
  • Biopsy pathology is the reference standard.

References

  • [Guideline / primary source]American College of Radiology. ACR BI-RADS Atlas, 5th edition. Reston, VA: ACR; 2013

Worked calculation

The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.

BI-RADS category (ultrasound/mammography)4A low suspicion

→BI-RADSBI-RADS 4A low suspicion

  • Malignancy likelihood (ACR BI-RADS Atlas, 5th ed., 2013):>2–≤10%
  • Triage:Tissue biopsy recommended.
  • Scope:This tool covers BI-RADS assessment and follow-up triage only; surgery and systemic therapy after diagnosis are decided by the breast team per current guidelines.
BI-RADS category (ultrasound/mammography)0 incomplete

→BI-RADSBI-RADS 0 incomplete

  • Malignancy likelihood (ACR BI-RADS Atlas, 5th ed., 2013):—
  • Triage:Needs additional imaging or comparison with prior studies before a final category.
  • Scope:This tool covers BI-RADS assessment and follow-up triage only; surgery and systemic therapy after diagnosis are decided by the breast team per current guidelines.
Verification & sources · governance
FAQ

Frequently asked questions

Does Breast Nodule Manager · BI-RADS Assessment & Follow-up upload patient data? Where is it calculated?
Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.
How is Breast Nodule Manager · BI-RADS Assessment & Follow-up calculated in practice? Can you show a worked example?
Inputs: BI-RADS category (ultrasound/mammography) 4A low suspicion → Result: BI-RADS BI-RADS 4A low suspicion(Malignancy likelihood (ACR BI-RADS Atlas, 5th ed., 2013): >2–≤10%, Triage: Tissue biopsy recommended., Scope: This tool covers BI-RADS assessment and follow-up triage only; surgery and systemic therapy after diagnosis are decided by the breast team per current guidelines.) Inputs: BI-RADS category (ultrasound/mammography) 0 incomplete → Result: BI-RADS BI-RADS 0 incomplete(Malignancy likelihood (ACR BI-RADS Atlas, 5th ed., 2013): —, Triage: Needs additional imaging or comparison with prior studies before a final category., Scope: This tool covers BI-RADS assessment and follow-up triage only; surgery and systemic therapy after diagnosis are decided by the breast team per current guidelines.)
Related tools