Guideline decision tool · Radiology
🔎

Spinal Canal Stenosis Measurements (Cervical / Lumbar) — free guideline decision tool

Cervical: canal AP diameter and Torg-Pavlov ratio. Lumbar: canal AP diameter, dural sac cross-sectional area, lateral recess and foraminal height, graded absolute / relative stenosis. Includes how to measure and what each value means. Instant, browser-side.

Open guideline tool →
Computed locally — no data uploaded. For licensed clinicians.
📋

Guideline-based

Implements the decision logic from published clinical guidelines.

🖥️

Runs in your browser

No installation. Enter the patient's values and get a guideline recommendation instantly.

🔒

Data stays local

Nothing is uploaded. Results are for licensed clinicians only.

Worked calculation

The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.

RegionCervical
Vertebral body AP diameter (Torg-Pavlov)17 mm
Cervical canal AP diameter12 mm

→Cervical canal AP diameter12mm

  • Cervical canal AP diameter:12 mm → 10–13 mm: relative stenosis
  • Torg-Pavlov ratio:0.71 → < 0.8: developmental cervical stenosis
RegionLumbar
Lumbar canal AP diameter11 mm
Dural sac CSA85 mm²
Lateral recess height3 mm
Foraminal height16 mm

→Lumbar canal AP diameter11mm

  • Lumbar canal AP diameter:11 mm → 10–12 mm: relative stenosis
  • Dural sac CSA:85 mm² → 75–100 mm²: relative stenosis
  • Lateral recess height:3 mm → ≥ 3 mm: normal

Common questions

What is Spinal Canal Stenosis Measurements (Cervical / Lumbar)?

Cervical: canal AP diameter and Torg-Pavlov ratio. Lumbar: canal AP diameter, dural sac cross-sectional area, lateral recess and foraminal height, graded absolute / relative stenosis. Includes how to measure and what each value means. Instant, browser-side.

How is Spinal Canal Stenosis Measurements (Cervical / Lumbar) calculated? What is the core formula?

Cervical canal AP diameter < 10 mm: absolute stenosis (high cord-compression risk) Cervical canal AP diameter 10–13 mm: relative stenosis Cervical canal AP diameter ≥ 13 mm: normal Torg-Pavlov ratio < 0.8: developmental cervical stenosis Torg-Pavlov ratio ≥ 0.8: normal Lumbar canal AP diameter < 10 mm: absolute stenosis Lumbar canal AP diameter 10–12 mm: relative stenosis Lumbar canal AP diameter ≥ 12 mm: normal Dural sac CSA < 75 mm²: absolute stenosis Dural sac CSA 75–100 mm²: relative stenosis Dural sac CSA ≥ 100 mm²: normal Lateral recess height < 3 mm: lateral recess stenosis Lateral recess height ≥ 3 mm: normal Foraminal height < 15 mm: possible foraminal stenosis (more likely if posterior disc height < 4 mm) Foraminal height ≥ 15 mm: normal

When is Spinal Canal Stenosis Measurements (Cervical / Lumbar) used?

Spine imaging: standing full-spine films, flexion/extension views, CT/MRI — scoliosis follow-up, adult deformity, stenosis reporting and surgical planning.

What are the key clinical points for Spinal Canal Stenosis Measurements (Cervical / Lumbar)?

Lateral cervical radiograph: canal AP diameter from the mid posterior vertebral body to the spinolaminar line; divided by the vertebral body AP diameter gives the Torg-Pavlov ratio (magnification-independent). Each value is graded against published reference ranges. Measurement technique and positioning change the numbers — compare like with like on follow-up. Part of the YuanDoctor MSK measurement topic.

What are the limits and cautions when using Spinal Canal Stenosis Measurements (Cervical / Lumbar)?

For licensed clinicians and clinical researchers. Interpret results with history, investigations and local protocols; not a diagnosis or prescription, and not a substitute for multidisciplinary decision-making or local guidelines.

Does Spinal Canal Stenosis Measurements (Cervical / Lumbar) upload patient data? Where is it calculated?

Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.

How is Spinal Canal Stenosis Measurements (Cervical / Lumbar) calculated in practice? Can you show a worked example?

Inputs: Region Cervical, Vertebral body AP diameter (Torg-Pavlov) 17 mm, Cervical canal AP diameter 12 mm → Result: Cervical canal AP diameter 12 mm(Cervical canal AP diameter: 12 mm → 10–13 mm: relative stenosis, Torg-Pavlov ratio: 0.71 → < 0.8: developmental cervical stenosis) Inputs: Region Lumbar, Lumbar canal AP diameter 11 mm, Dural sac CSA 85 mm², Lateral recess height 3 mm, Foraminal height 16 mm → Result: Lumbar canal AP diameter 11 mm(Lumbar canal AP diameter: 11 mm → 10–12 mm: relative stenosis, Dural sac CSA: 85 mm² → 75–100 mm²: relative stenosis, Lateral recess height: 3 mm → ≥ 3 mm: normal)

🔎

Run Spinal Canal Stenosis Measurements (Cervical / Lumbar) now

Cervical: canal AP diameter and Torg-Pavlov ratio. Lumbar: canal AP diameter, dural sac cross-sectional area, lateral recess and foraminal height, graded absolute / relative stenosis. Includes how to measure and what each value means. Instant, browser-side.

Open guideline tool →

For licensed clinicians. Not a substitute for clinical judgement.

Share on XLinkedInWhatsAppEmail

Paste the link in Slack, Teams, X, or LinkedIn — the preview image comes from this page’s Open Graph card.

Related guideline tools