Guideline decision tool · Radiology
⭕

Glenoid Bone Loss & Glenoid Track (On / Off-Track) — free guideline decision tool

Best-fit circle on en-face CT gives glenoid bone loss %; with the Hill-Sachs interval it determines on-/off-track and distance to dislocation (DTD). Includes how to measure and what each value means. Instant, browser-side.

Open guideline tool →
Computed locally — no data uploaded. For licensed clinicians.
📋

Guideline-based

Implements the decision logic from published clinical guidelines.

🖥️

Runs in your browser

No installation. Enter the patient's values and get a guideline recommendation instantly.

🔒

Data stays local

Nothing is uploaded. Results are for licensed clinicians only.

Worked calculation

The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.

Best-fit circle diameter D26 mm
Anterior defect width d4 mm
Hill-Sachs interval HSI (optional)15 mm

→Glenoid bone loss15.4%

  • Glenoid bone loss:15.4 % → 13.5–20%: subcritical (higher failure of isolated Bankart)
  • Glenoid track:0.83 × 26 − 4 = 17.6 mm
  • Track status:On-track (HSI 15 ≤ 17.6 mm)

Common questions

What is Glenoid Bone Loss & Glenoid Track (On / Off-Track)?

Best-fit circle on en-face CT gives glenoid bone loss %; with the Hill-Sachs interval it determines on-/off-track and distance to dislocation (DTD). Includes how to measure and what each value means. Instant, browser-side.

How is Glenoid Bone Loss & Glenoid Track (On / Off-Track) calculated? What is the core formula?

Glenoid bone loss < 13.5%: minor Glenoid bone loss 13.5–20%: subcritical (higher failure of isolated Bankart) Glenoid bone loss ≥ 20%: critical — consider bone block (eg, Latarjet; some use 25%)

When is Glenoid Bone Loss & Glenoid Track (On / Off-Track) used?

Shoulder imaging: true AP, Y view and 3D CT — rotator cuff disease and instability reporting and procedure selection.

What are the key clinical points for Glenoid Bone Loss & Glenoid Track (On / Off-Track)?

3D CT en-face view of the glenoid with the humeral head subtracted (or oblique sagittal). Each value is graded against published reference ranges. Measurement technique and positioning change the numbers — compare like with like on follow-up. Part of the YuanDoctor MSK measurement topic.

What are the limits and cautions when using Glenoid Bone Loss & Glenoid Track (On / Off-Track)?

For licensed clinicians and clinical researchers. Interpret results with history, investigations and local protocols; not a diagnosis or prescription, and not a substitute for multidisciplinary decision-making or local guidelines.

Does Glenoid Bone Loss & Glenoid Track (On / Off-Track) upload patient data? Where is it calculated?

Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.

How is Glenoid Bone Loss & Glenoid Track (On / Off-Track) calculated in practice? Can you show a worked example?

Inputs: Best-fit circle diameter D 26 mm, Anterior defect width d 4 mm, Hill-Sachs interval HSI (optional) 15 mm → Result: Glenoid bone loss 15.4 %(Glenoid bone loss: 15.4 % → 13.5–20%: subcritical (higher failure of isolated Bankart), Glenoid track: 0.83 × 26 − 4 = 17.6 mm, Track status: On-track (HSI 15 ≤ 17.6 mm))

⭕

Run Glenoid Bone Loss & Glenoid Track (On / Off-Track) now

Best-fit circle on en-face CT gives glenoid bone loss %; with the Hill-Sachs interval it determines on-/off-track and distance to dislocation (DTD). Includes how to measure and what each value means. Instant, browser-side.

Open guideline tool →

For licensed clinicians. Not a substitute for clinical judgement.

Share on XLinkedInWhatsAppEmail

Paste the link in Slack, Teams, X, or LinkedIn — the preview image comes from this page’s Open Graph card.

Related guideline tools

For use by licensed clinicians and clinical researchers. Computed locally in your browser — no data is uploaded. Not a substitute for clinical judgement.

Water does not race to be first — it strives only to flow on, unbroken

Yuan Doctor
Tertiary-hospital clinical team · local compute · no upload
© 2026 Yuan Doctor · www.yuandoctor.com · Developed & reviewed by a tertiary-hospital clinical team