Breast Multimodality BI-RADS Synthesis (Mammo / DBT / US / MRI / CEM / CEUS) — free guideline decision tool
Combine BI-RADS categories from mammography/DBT, US, MRI, CEM and CEUS into one overall assessment by the ACR abnormality hierarchy, with discordance alerts. Instant, browser-side.
Open guideline tool →Guideline-based
Implements the decision logic from published clinical guidelines.
Runs in your browser
No installation. Enter the patient's values and get a guideline recommendation instantly.
Data stays local
Nothing is uploaded. Results are for licensed clinicians only.
Worked calculation
The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.
| Mammography / DBT | 4A |
|---|---|
| Ultrasound | 4A |
| MRI | 4A |
| Contrast-enhanced mammography (CEM) | 4A |
| Contrast-enhanced US (not an ACR category; supplementary) | 4A |
→Overall BI-RADS4A
- Modalities:Mammo/DBT 4A · US 4A · MRI 4A · CEM 4A · CEUS 4A
- Driving modality:Mammo/DBT (BI-RADS 4A)
- Likelihood of malignancy:>2–≤10%
| Mammography / DBT | 0 — Incomplete |
|---|---|
| Ultrasound | 0 — Incomplete |
| MRI | 0 — Incomplete |
| Contrast-enhanced mammography (CEM) | 0 — Incomplete |
| Contrast-enhanced US (not an ACR category; supplementary) | 0 — Incomplete |
→Overall BI-RADS0
- Modalities:Mammo/DBT 0 · US 0 · MRI 0 · CEM 0 · CEUS 0
- Driving modality:Mammo/DBT (BI-RADS 0)
- Likelihood of malignancy:—
Common questions
What is Breast Multimodality BI-RADS Synthesis (Mammo / DBT / US / MRI / CEM / CEUS)?
Combine BI-RADS categories from mammography/DBT, US, MRI, CEM and CEUS into one overall assessment by the ACR abnormality hierarchy, with discordance alerts. Instant, browser-side.
How is Breast Multimodality BI-RADS Synthesis (Mammo / DBT / US / MRI / CEM / CEUS) calculated? What is the core formula?
Overall = most abnormal ACR modality; hierarchy 1<2<3<6<0<4A<4B<4C<5. CEUS is advisory only.
When is Breast Multimodality BI-RADS Synthesis (Mammo / DBT / US / MRI / CEM / CEUS) used?
When one patient has several breast imaging modalities and needs a single overall assessment.
What are the key clinical points for Breast Multimodality BI-RADS Synthesis (Mammo / DBT / US / MRI / CEM / CEUS)?
Most abnormal finding wins. Hierarchy 1<2<3<6<0<4<5. Suspicious only on MRI/CEM → second-look US. CEUS is supplementary.
What are the limits and cautions when using Breast Multimodality BI-RADS Synthesis (Mammo / DBT / US / MRI / CEM / CEUS)?
For licensed clinicians and clinical researchers. Interpret results with history, investigations and local protocols; not a diagnosis or prescription, and not a substitute for multidisciplinary decision-making or local guidelines.
Does Breast Multimodality BI-RADS Synthesis (Mammo / DBT / US / MRI / CEM / CEUS) upload patient data? Where is it calculated?
Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.
How is Breast Multimodality BI-RADS Synthesis (Mammo / DBT / US / MRI / CEM / CEUS) calculated in practice? Can you show a worked example?
Inputs: Mammography / DBT 4A, Ultrasound 4A, MRI 4A, Contrast-enhanced mammography (CEM) 4A, Contrast-enhanced US (not an ACR category; supplementary) 4A → Result: Overall BI-RADS 4A(Modalities: Mammo/DBT 4A · US 4A · MRI 4A · CEM 4A · CEUS 4A, Driving modality: Mammo/DBT (BI-RADS 4A), Likelihood of malignancy: >2–≤10%) Inputs: Mammography / DBT 0 — Incomplete, Ultrasound 0 — Incomplete, MRI 0 — Incomplete, Contrast-enhanced mammography (CEM) 0 — Incomplete, Contrast-enhanced US (not an ACR category; supplementary) 0 — Incomplete → Result: Overall BI-RADS 0(Modalities: Mammo/DBT 0 · US 0 · MRI 0 · CEM 0 · CEUS 0, Driving modality: Mammo/DBT (BI-RADS 0), Likelihood of malignancy: —)
Run Breast Multimodality BI-RADS Synthesis (Mammo / DBT / US / MRI / CEM / CEUS) now
Combine BI-RADS categories from mammography/DBT, US, MRI, CEM and CEUS into one overall assessment by the ACR abnormality hierarchy, with discordance alerts. Instant, browser-side.
Open guideline tool →For licensed clinicians. Not a substitute for clinical judgement.
Paste the link in Slack, Teams, X, or LinkedIn — the preview image comes from this page’s Open Graph card.