DWI / ADC Calculator & Reference Values (with rADC) — free guideline decision tool
Compute ADC from two b-values or enter it directly, get rADC against a reference tissue, and compare with literature thresholds for prostate, breast and acute ischemia. Instant, browser-side.
Open guideline tool →Guideline-based
Implements the decision logic from published clinical guidelines.
Runs in your browser
No installation. Enter the patient's values and get a guideline recommendation instantly.
Data stays local
Nothing is uploaded. Results are for licensed clinicians only.
Worked calculation
The values below come from this tool's own example placeholders and are computed server-side with the formula shown on this page, so the arithmetic can be checked quickly. It demonstrates how to substitute values only — it is not clinical advice and not a real case.
| Low b-value | 0 s/mm² |
|---|---|
| Signal at low b | 820 |
| High b-value | 800 s/mm² |
| Signal at high b | 310 |
| Or lesion ADC directly | 0.85 ×10⁻³ mm²/s |
| Organ | Prostate |
→ADC0.850×10⁻³ mm²/s
- ADC:0.850 ×10⁻³ mm²/s = 850 µm²/s (entered)
- Reference cue:750–900 µm²/s: suspicious range (PI-RADS scoring remains visual)
- Caveat:ADC depends on b-value pair, field strength, vendor and ROI placement; validate thresholds on local scanners.
Common questions
What is DWI / ADC Calculator & Reference Values (with rADC)?
Compute ADC from two b-values or enter it directly, get rADC against a reference tissue, and compare with literature thresholds for prostate, breast and acute ischemia. Instant, browser-side.
How is DWI / ADC Calculator & Reference Values (with rADC) calculated? What is the core formula?
ADC = ln(S_low/S_high)/(b_high − b_low); rADC = lesion ADC / reference ADC.
When is DWI / ADC Calculator & Reference Values (with rADC) used?
Quantitative DWI reporting, research measurements and cross-scanner comparison.
What are the key clinical points for DWI / ADC Calculator & Reference Values (with rADC)?
ADC = ln(S1/S2)/(b2 − b1). Prostate 750–900 µm²/s. Breast ~1.30×10⁻³ mm²/s. Ischemic core <620 µm²/s.
What are the limits and cautions when using DWI / ADC Calculator & Reference Values (with rADC)?
For licensed clinicians and clinical researchers. Interpret results with history, investigations and local protocols; not a diagnosis or prescription, and not a substitute for multidisciplinary decision-making or local guidelines.
Does DWI / ADC Calculator & Reference Values (with rADC) upload patient data? Where is it calculated?
Calculation runs locally in the browser; inputs and results are not uploaded. For licensed clinicians only; interpret with history, investigations and local protocols — not a diagnosis or prescription.
How is DWI / ADC Calculator & Reference Values (with rADC) calculated in practice? Can you show a worked example?
Inputs: Low b-value 0 s/mm², Signal at low b 820, High b-value 800 s/mm², Signal at high b 310, Or lesion ADC directly 0.85 ×10⁻³ mm²/s, Organ Prostate → Result: ADC 0.850 ×10⁻³ mm²/s(ADC: 0.850 ×10⁻³ mm²/s = 850 µm²/s (entered), Reference cue: 750–900 µm²/s: suspicious range (PI-RADS scoring remains visual), Caveat: ADC depends on b-value pair, field strength, vendor and ROI placement; validate thresholds on local scanners.)
Run DWI / ADC Calculator & Reference Values (with rADC) now
Compute ADC from two b-values or enter it directly, get rADC against a reference tissue, and compare with literature thresholds for prostate, breast and acute ischemia. Instant, browser-side.
Open guideline tool →For licensed clinicians. Not a substitute for clinical judgement.